Data set: 1 kW panel radiator LISA 22-070-2500 (00.03.000)

Full name
1 kW panel radiator LISA 22-070-2500
Location
LV
Reference year
2023
Valid until
2028
Reference flow(s)
Type
EPD
Parameterized?
no
LCIA results included?
yes
Category
Bygg
Synonyms
Use advice for data set
LCA has been performed as “Cradle-to-gate with options, modules C1-C4 and module D”, including also module A4. All major materials, resource and energy use in manufacturing, as well as waste are included for phases A1-A3, A4, C1-C4 and D, see flowchart below. The following information describes the scenarios in the different modules of the EPD.
Data set use approval
General comment
The production data are from 2022, the database data are from 2013 – 2021 i.e. no data is older than 10 years. Database used is mainly Ecoinvent v3.8, with an addition of Carbon Minds 2022.01. The LCA software used is SimaPro 9.4. General allocation principles were applied according to ISO 14044:2006 4.3.4 and in line with the provisions of EN 15804:2012+A2. Incoming energy, water and generation of waste are allocated equally among all products through mass allocation. The material and energy consumption in manufacturers’ data according to recorded production is also indicated per piece of the products produced as radiator that is able to produce 1 kW of heat is of specific dimensions and weight of materials. The effects of primary production of recycled materials has been allocated to the main product in which the material has been used. LISA Hot Water radiators are produced only in one manufacturing plant. All materials have been accounted for in the LCA according to the data provided by manufacturer. There is no missing data for processes in the system boundaries. All the materials and processes, which have been accounted for by the manufacturing company for the relevant manufacturing process are included in the LCI. Flows excluded from the study because of the insignificance and difficulty of attributing them to a particular reference product are listed below: • Copper scrap from sharpening of electrodes (0.001 kg) General cut-off criteria are given in standard EN 15804:2012+A2, clause 6.3.6. This cut-off rule does not apply for hazardous materials and substances and it is consistent with EN 15804+A2. Infrastructure processes, e.g. manufacturing and maintenance of facilities and manufacturing equipment, have been excluded from this LCA study.
LCI Method Principle
LCI Method Approaches
No records found.
Completeness of product model
No statement
Reviews
  • Independent external review by
License and access conditions
Copyright
yes
License type
Free of charge for all users and uses
Access information
None
Owner of data set
Lyngson SIA
Technical purpose
Radiator/convector LISA 22-070-2500 is produced out of steel plates and rectangular steel pipes as a panel heater with external connection of thermostat and side connections to the infrastructure of the heating systems. These devices have a wide range of applications in closed environments, both in new construction and renovations. The product composition is Steel and Coating powder
Input Products
No records found.
Co-Products
No records found.
Data set version
00.03.000
Time stamp (last saved)
2024-02-21T09:28:20
Data set format
Compliance systems
  • EN 15804+A2 (Overall compliance: Fully compliant)
  • ISO 14025 (Overall compliance: Fully compliant)
  • ISO 21930 (Overall compliance: Fully compliant)
Tag
Data Set deregistration
Are you sure you want to deregister selected dataset?
Please enter the reason of deregistration and confirm.