soda4LCA
Data stock: PUBLIC

Process data set overview page

Data set: AMALJ-TT E Path 3x400/50 ALCL 12kV lcAL (00.02.001)

Full name
AMALJ-TT E Path 3x400/50 ALCL 12kV lcAL
Location
SE
Reference year
2025
Valid until
2030
Reference flow(s)
Type
EPD
Parameterized?
no
LCIA results included?
yes
Category
Bygg / Elektroniske og elektriske komponenter og produkter
Synonyms
Use advice for data set
Data set use approval
General comment
Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
LCI Method Principle
LCI Method Approaches
No records found.
Completeness of product model
No statement
Reviews
  • Independent external review by
License and access conditions
Copyright
yes
License type
Free of charge for all users and uses
Access information
None
Owner of data set
Prysmian Group Sverige AB
Technical purpose
Totally water sealed three core power cable designed for installation in air, direct in ground and in water (with limited depth and moderate currents). Included in the E Path concept, the cable is evaluated and designed with sustainability in mind. The outer sheath is of 90% recycled (post-consumer scrap) and as insulation system the cable uses Prysmians premium thermoplastic material: P-laser that ensure outstanding performance and recyclability. Radially water sealed byan aluminium laminate bonded to the outer sheath and longitudinally water sealed with swellable tapes.The screen is made up of circular corrosion protected aluminium wires that are covered with a semi-conductive material. By using the two strong ripcords stripping of the jacket becomes easier and safer for both man and cable. Conductor design Stranded, round, compacted aluminum class 2, longitudinal water sealed Conductor material Aluminium Inner semi-conducting layer Yes Core insulation material Polypropylene Outer semi-conducting layer Yes Screen construction Aluminum wire Material outer sheath MDPE Laminated sheath Yes Longitudinal water blocking screen Yes Rip cord Yes UV resistant Yes
Input Products
No records found.
Co-Products
No records found.
Data set version
00.02.001
Time stamp (last saved)
2025-11-30T21:18:01
Data set format
Compliance systems
  • EN 15804+A2 (Overall compliance: Fully compliant)
  • ISO 14025 (Overall compliance: Fully compliant)
  • ISO 21930 (Overall compliance: Fully compliant)
Tag
Data Set deregistration
Are you sure you want to deregister selected dataset?
Please enter the reason of deregistration and confirm.