Data set: Medium-voltage switchgear UniGear ZS1 12.12.32 IF, BT, LDU 650mm(w/CT, VT, CB) (00.05.000)
A more recent version of this data set exists in the database.
Most recent version of this data set:
00.06.000
Other versions:
00.04.000
00.03.000
View entire data set
Download data set as XML file
Download as ZIP file
Full name
Medium-voltage switchgear UniGear ZS1 12.12.32 IF, BT, LDU 650mm(w/CT, VT, CB)
Location
Reference year
2025
Valid until
2030
Reference flow(s)
Medium-voltage switchgear UniGear ZS1 12.12.32 IF, BT, LDU 650mm(w/CT, VT, CB) - 1.0 * 1.0 Stück (Number of pieces)
Type
EPD
Parameterized?
no
LCIA results included?
yes
Category
Byggevarer
Synonyms
Use advice for data set
The life cycle assessment is a “cradle-to-grave” analysis, and the system boundaries are defined according to EN 50693, as required by the PCR EPDItaly007. For transparency reasons, the manufacturing stage is further divided into an upstream and core stage.
Data set use approval
General comment
Both primary and secondary data are used. The main sources for primary data are the bill of materials, technical drawings, and site-specific foreground data provided by ABB. For all processes for which primary data are not available, generic background data originating from the ecoinvent v3.9.1 database, with system model “allocation, cut-off by classification”, are used. The LCA software used for the calculations is SimaPro 9.5. The utility consumption and waste generation by ABB, in the core manufacturing stage, is allocated to the production of one reference product according to applicable rules. For the end-of-life allocation, the “Polluter Pays” principle is adopted according to what is defined in the CEN/TR 16970 standard. However, the potential benefits and avoided loads from recovery and recycling processes are not considered because it is not required by the PCR. According to PCR, the cut-off criteria can be set to a maximum of 2 % of the overall environmental impacts. In this LCA, stickers have been excluded as their weights are negligible. Process black oxide and phosphate conversion coating have also been excluded due to the model complexity and unavailability of data.
LCI Method Principle
LCI Method Approaches
No records found.
Completeness of product model
No statement
Reviews
Independent external review by
Elisabet Amat
License and access conditions
Copyright
yes
License type
Free of charge for all users and uses
Access information
None
Owner of data set
ABB Switzerland Ltd, Group Technology Management
Technical purpose
Medium-voltage air-insulated switchgear UniGear ZS1 is the ABB mainline global switchgear up to 24 kV, 4000 A, 63 kA. UniGear ZS1 is used to distribute electric power in a variety of demanding applications such as on offshore platforms, in container or cruise ships, in mines as well as in utility substations, power plants or chemical plants. Panels are available as a single busbar, double busbar, back-to-back or double level solution.
Input Products
No records found.
Co-Products
No records found.
Data set version
00.05.000
Time stamp (last saved)
2025-08-07T16:03:15
Data set format
Other versions
00.06.000
00.04.000
00.03.000
Compliance systems
EN 15804+A2 (Overall compliance: Fully compliant)
ISO 14025 (Overall compliance: Fully compliant)
ISO 21930 (Overall compliance: Fully compliant)
Tag
Data Set deregistration
Are you sure you want to deregister selected dataset?
Please enter the reason of deregistration and confirm.
Yes