soda4LCA
Data stock: PUBLIC

Process data set overview page

Data set: Prefix PP16mm rør Halogenfri (00.03.000)

Full name
Prefix PP16mm rør Halogenfri
Location
NO
Reference year
2025
Valid until
2030
Reference flow(s)
Type
EPD
Parameterized?
no
LCIA results included?
yes
Category
Bygg / Elektroniske og elektriske komponenter og produkter
Synonyms
Use advice for data set
Cradle to Gate. The following stages have been declared: A1-A4
Data set use approval
General comment
Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Data from material supplier and the LCA generator has been accepted "As-Is" Data from processing TECCON in-house has been repeated ongoingly without major deviations. Figures given in document are worst case values. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. The allocation is made in accordance with the guidelines given in EN 15804. Raw material - Information derived from manufactory and from a LCA generator Processing: Derived from actual measurements during production of the individual units/stages. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. All major materials have been included. Substance representing <1% have not been included. This include folio film for packaging!
LCI Method Principle
LCI Method Approaches
No records found.
Completeness of product model
No statement
Reviews
  • Independent external review by
License and access conditions
Copyright
yes
License type
Free of charge for all users and uses
Access information
None
Owner of data set
TECCON Norge AS
Technical purpose
Prefix pre-wired corrugated, Halogen free pliable / self-recovering conduit acc. to EN 61386-1 and EN 61386-22. Halogenfree KNX/EIB cable for transmission of BUS signals in intelegent building management systems based on standards of the Europeing Informatiin BUS EIB. Signals received from system sensors (Lighting, temperature, air conditioning, access control and others) are gathered in the EIB bus, and subsequently processed and used to control a device's operation. . The screen mimimizes EMC effects as susceptibility to noise and reduction of frequency emission. KNX: Worldvide standard for home and building control. EIB: Europaing Installation Bus. Halogen-free pipe and cables offer enhanced protection against smoke and toxid gases developed during fire. Products fulfils requirements of norms concerning quantity of toxic chemical compounds giving off during combustion. EN50575 CPR Class Dca CONDUIT Construction standards EN 611386-1; EN 61386-22 ICTA 34423 CABLE Construction - Factory standard
Input Products
No records found.
Co-Products
No records found.
Data set version
00.03.000
Time stamp (last saved)
2025-06-28T20:08:49
Data set format
Compliance systems
  • EN 15804+A2 (Overall compliance: Fully compliant)
  • ISO 14025 (Overall compliance: Fully compliant)
  • ISO 21930 (Overall compliance: Fully compliant)
Tag
Data Set deregistration
Are you sure you want to deregister selected dataset?
Please enter the reason of deregistration and confirm.