Go to main content [shortcut key S], by skipping site tools, language selector, navigation path and navigation menu
Go to navigation menu, by skipping site tools, language selector and navigation path
soda4LCA
Selected data stock:
REFERENCE_DATA
PUBLIC
InData_2018
REFERENCE_DATA
PUBLIC
InData_2018
Data stock: PUBLIC
Home
Browse Data Sets
Processes
LCIA Methods
Elementary Flows
Product Flows
Flow Properties
Unit Groups
Sources
Contacts
Search Data Sets
Search Processes
Process data set overview page
Data set: AXLJ-RMF Eco Cable 3x240/35 LT 12kV (00.03.000)
A more recent version of this data set exists in the database.
Most recent version of this data set:
00.04.000
View entire data set
Download data set as XML file
Download as ZIP file
Full name
AXLJ-RMF Eco Cable 3x240/35 LT 12kV
Location
SE
Reference year
2024
Valid until
2029
Reference flow(s)
AXLJ-RMF Eco Cable 3x240/35 LT 12kV - 1.0 * 1.0 m (Length)
Type
EPD
Parameterized?
no
LCIA results included?
yes
Category
Bygg / Elektriske kabler
Synonyms
Use advice for data set
Data set use approval
General comment
Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
LCI Method Principle
LCI Method Approaches
No records found.
Completeness of product model
No statement
Reviews
Independent external review by
Vito D’Incognito
License and access conditions
Copyright
yes
License type
Free of charge for all users and uses
Access information
None
Owner of data set
Prysmian Group Sverige AB
Technical purpose
AXLJ-RMF is a 3-core cable designed for replacement of bare overhead lines. Primary developed to be ploughed down but thanks to the robust design the cable can stand the stresses that appears when laid in water with moderate currents and limited depth. Ripcords for easier and safer stripping of the outer sheath. Designed and tested according to HD 620 Part 10 Section M and K. Conductor design Stranded, round, compacted aluminium, longitudinal water sealed Conductor material Aluminium Core insulation material XLPE Screen construction Wire screen Material outer sheath MDPE Rip cord Yes UV resistant Yes
Input Products
No records found.
Co-Products
No records found.
Data set version
00.03.000
Time stamp (last saved)
2024-03-17T16:02:14
Data set format
Other versions
00.04.000
Compliance systems
EN 15804+A2 (Overall compliance: Fully compliant)
ISO 14025 (Overall compliance: Fully compliant)
ISO 21930 (Overall compliance: Fully compliant)
Tag
Data Set deregistration
Are you sure you want to deregister selected dataset?
Please enter the reason of deregistration and confirm.
Yes