soda4LCA
Data stock: PUBLIC

Process data set overview page

Data set: LAPP ÖLFLEX CLASSIC 115 CY 2X0,75 BK Elnr 1025152 (00.03.000)

Full name
LAPP ÖLFLEX CLASSIC 115 CY 2X0,75 BK Elnr 1025152
Location
FR
Reference year
2025
Valid until
2030
Reference flow(s)
Type
EPD
Parameterized?
no
LCIA results included?
yes
Category
Bygg / Elektroniske og elektriske komponenter og produkter
Synonyms
Use advice for data set
1m LAPP ÖLFLEX CLASSIC 115 CY 2X0,75 BK Elnr 1025152
Data set use approval
General comment
Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
LCI Method Principle
LCI Method Approaches
No records found.
Completeness of product model
No statement
Reviews
  • Independent external review by
License and access conditions
Copyright
yes
License type
Free of charge for all users and uses
Access information
None
Owner of data set
Lapp Norway AS
Technical purpose
ÖLFLEX CLASSIC 115 CY BK cables are control cables for occasional flexible use and fixed installation under medium mechanical load conditions. They are also suitable for use in dry, damp or wet areas. They are suitable for outdoor use if the indicated temperature range is observed. They are largely resistant to acids, alkalis and certain oils at room temperature. ÖLFLEX CLASSIC 115 CY BK cables are suitable for occasional, non-automated movements. They meet the requirements for slow rotational movements, such as in the loop of a wind turbine. The maximum tensile load is 15 N/mm² of conductor cross-section during installation and operation. Compulsory guidance is not permitted. The screening braid protects against interference from electrical fields. Application range: Control units for machine tools, conveyor systems, measurement and control technology, office machines and systems for data processing. This cable is suitable for torsion application in wind turbines (WTG). The torsional load is limited to applications, as they typically occur in the loop of a wind turbine. Design based on EN 50525-2-51 Certification EN 13501-6 and EN 50575 Classification of fire behaviour (article/dimension range see www.lappkabel.com/cpr) Conductor fine wire strands of bare copper acc. to IEC 60228 resp. EN IEC 60228, class 5 Insulation PVC compound TI2 acc. to EN 50363-3 with increased requirements acc. to Lapp specification Core identification code acc. to VDE 0293-1, with or without GN/YE ground conductor black cores with white numbers acc. to EN 50334 Cable assembly cores are stranded in layers Wrapping plastic foil Screen braid of tinned copper, coverage = 85 % (nominal value) Outer sheath PVC compound TM2 acc. to EN 50363-4-1 with increased requirements acc. to LAPP specification colour: black, similar RAL 9005
Input Products
No records found.
Co-Products
No records found.
Data set version
00.03.000
Time stamp (last saved)
2025-05-19T13:58:04
Data set format
Compliance systems
  • EN 15804+A2 (Overall compliance: Fully compliant)
  • ISO 14025 (Overall compliance: Fully compliant)
  • ISO 21930 (Overall compliance: Fully compliant)
Tag
Data Set deregistration
Are you sure you want to deregister selected dataset?
Please enter the reason of deregistration and confirm.