EPD Global Digi Node
Data stock: PUBLIC

Process data set overview page

0.6/1KV 50X4C CAL XLPE LOBAC 01.00.001

Full name
0.6/1KV 50X4C CAL XLPE LOBAC
Location
AU
Reference year
2026
Valid until
2031
Reference flow(s)
Type
EPD
Parameterized?
no
LCIA results included?
yes
Category
Synonyms
Use advice for data set
Data set use approval
General comment
Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
LCI Method Principle
LCI Method Approaches
No records found.
Completeness of product model
No statement
Reviews
License and access conditions
Copyright
yes
License type
Free of charge for all users and uses
Access information
None
Owner of data set
Prysmian New Zealand Ltd
Technical purpose
The cable consists of four 50mm² compact stranded aluminium conductors insulated with X-90-UV XLPE compound. It is designed for low voltage power distribution applications requiring lightweight construction and reliable electrical performance. Application- Suitable for low voltage power distribution networks, industrial installations and infrastructure projects. The cable is intended for fixed installation in air, cable trays and ducts where a 0.6/1kV rated power cable is required. AS/NZS 3560.1 AS/NZS 1125
Input Products
No records found.
Co-Products
No records found.
Data set version
01.00.001
Time stamp (last saved)
2026-09-14T21:58:51
Data set format
Compliance systems
  • EN 15804+A2 (Overall compliance: Fully compliant)
  • ISO 14025 (Overall compliance: Fully compliant)
  • ISO 21930 (Overall compliance: Fully compliant)
Tag
Data Set deregistration
Are you sure you want to deregister selected dataset?
Please enter the reason of deregistration and confirm.