| Key Data Set Information | |
| Location | CH |
| Geographical representativeness description | Europe |
| Reference year | 2025 |
| Name |
|
| Use advice for data set | The life cycle analysis of the RTU530 module follows a “cradle to grave” analysis and covers the following life cycle stages: manufacturing stage (A1-A2), including the relevant upstream process (e.g. acquisition of raw material, preparation of semi-finished goods, etc.) and the main manufacturing and processing steps (A3); distribution stage (A4); installation stage (A5), including the relevant steps for the preparation of the product for use; use stage (B6), including the required maintenance steps within the reference service life (RSL) associated to the reference product; and end-of-life stage, including the necessary steps until and for the final disposal or recovery of the product system (C1-C4, D). |
| Technical purpose of product or process | For more information about the EPD or the product, please use our 'Contact Us' page and a member of the Hitachi Energy team will connect with you: https://www.hitachienergy.com/contact-us As the distribution network becomes more intelligent, there is a growing need for independent monitoring and control devices to handle many different tasks. RTU530 delivers a new set of features and solutions for the secondary distribution automation segment in addition to many other applications. The device’s highly customizable design enables the adaptation of input and output modules based on application requirements while a robust design and optional conformal coating guarantee a long cycle life. Low power consumption enables a greener installation while optimizing the capacity of UPS batteries. All come embedded with enhanced cybersecurity features such as secure communication, encryption, and security logging which are part of the DNA of the RTU500 series. RTU530’s compact size allows fitting into small control cabinets, while intuitive handling and user-friendly design enables faster project execution. The RTU530 product that features in the life cycle assessment is the 530CID01, a communication module consisting of a communication unit (CMU), a multi I/O module (IOM) and a power supply in a compact and robust DIN rail housing. The essential tasks are: • Managing and controlling of the RTU530 product line I/O modules via the interface to the serial I/O bus. • Reading Process events from the input modules and sending commands to the output modules. • Communicating with control systems, local HMI systems, sub-RTUs, IEDs or multimeter devices via the serial interfaces and the Ethernet interface. • Managing the time base for the RTU530 product line station and synchronizing the I/O modules. • Handling the dialog between RTU530 product line and Web-Browser via the LAN and USB interfaces. EPDs for other modules are also available. |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Both primary and secondary data were used in the construction of the RTU530 module LCA. Primary product data was collected from the bill of materials, technical documentation and supplier input, and primary assembly site data was collected from Hitachi Energy’s environmental performance database. All production site and technical data was from 2023 and collected during 2024. Secondary data supplemented the primary data for upstream material production and manufacturing, transport, use phase and end-of-life processes, as well as defining resource flows such as electricity mixes. The main database was ecoinvent, supported by other sources and all secondary data was compiled by LCA.no. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2030 |
| Time representativeness description | 2025-07-21 - 2030-07-21 |
| Technological representativeness | |
| Technology description including background system | Further information on the general technical features and specifications of the RTU530 product line is available on our website: https://www.hitachienergy.com/products-and-solutions/substation-automation-protection-and-control/products/remote-terminal-units/rtu530-product-line |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2025-08-10T17:05:10 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | f855016d-8732-46e4-97cc-e8facac332ec |
| Date of last revision | 2025-07-21T07:46:50.2153206Z |
| Data set version | 00.03.000 |
| Registration authority | |
| Registration number | NEPD-11872-11826 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle