Close Go back Collapse all sections
Process Data set: Glamox heating 3001 TPA 10 (en) en

Key Data Set Information
Location LT
Geographical representativeness description Europe.
Reference year 2025
Name
Glamox heating 3001 TPA 10
Technical purpose of product or process Glamox heating 3001 is a panel heater with a focus on function, flexibility and energy efficiency. • Choose from several different thermostats: WIFI (WT2), Digital (DT), and slave modules: SLX, SLA-5/24 and EIB. • With Glamox Heating Wifi App Connect easily to your Wi-Fi router at home, at the office or at your cabin. • Glamox heaters 3001, TPA and TLO, is IP20, double insulated Class II and has overheating protection. • 5 years warranty. • Available as TPA with height 355 mm and TLO with hight 180 mm. • Available in 230V and 400V. • Color: White RAL 9010. • Can be mounted on floor stand (optional).
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 7.99056603E-4 kg
  • Carbon content (biogenic) - packaging: 0.293495580026 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-04-03 - 2030-04-03
Technological representativeness

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 67.39
  • 0.04057
  • 13.93
  • 0.198
  • 0.002369
  • 2.917E+4
  • 0
  • 0.0594
  • 0.06948
  • 0.2189
  • -20.86
Input
  • 5.488
  • 0
  • 0
  • 0
  • -5.464
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 72.88
  • 0.04057
  • 13.93
  • 0.198
  • -5.462
  • 2.917E+4
  • 0
  • 0.0594
  • 0.06948
  • 0.2189
  • -20.86
Input
  • 593.7
  • 3.225
  • 18.44
  • 13.83
  • 0.1436
  • 1.507E+5
  • 0
  • 4.149
  • 0.5707
  • 0.8636
  • -66.93
Input
  • 14.53
  • 0
  • 0
  • 0
  • -0.02431
  • 0
  • 0
  • 0
  • -14.5
  • 0
  • 0
Input
  • 608.3
  • 3.225
  • 18.44
  • 13.83
  • 0.1193
  • 1.507E+5
  • 0
  • 4.149
  • -13.93
  • 0.8636
  • -66.93
Input
  • 2.102
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.004515
  • 0.00825
Input
  • 1.526
  • 0.001419
  • 0.2786
  • 0.007083
  • 0.0000785
  • 2126
  • 0
  • 0.002125
  • 0.00124
  • 0.001329
  • 0.07206
Input
  • 0.1915
  • 0.004756
  • 0.05123
  • 0.02533
  • 0.0003233
  • 505.1
  • 0
  • 0.007598
  • -0.00004349
  • 0.03919
  • 2.02
Input
  • 0.4532
  • 0.000367
  • 0.01249
  • 0.001479
  • 0.00006788
  • 127.8
  • 0
  • 0.0004437
  • 0.001045
  • 0.0007484
  • -0.09341
Output
  • 0.3212
  • 0.0001765
  • 0.07718
  • 0.0007133
  • 0
  • 22.66
  • 0
  • 0.000214
  • 0.00002146
  • 0.2447
  • -0.00132
Output
  • 11.05
  • 0.2803
  • 1.219
  • 0.6726
  • 0.6341
  • 509.8
  • 0
  • 0.2018
  • 0.02903
  • 1.222
  • -1.909
Output
  • 0.001719
  • 0.00002202
  • 0.0001009
  • 0.00009421
  • 0
  • 1.076
  • 0
  • 0.00002826
  • 0.000001066
  • 0.000002586
  • -0.0001854
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 1.237
  • 0
  • 0.5893
  • 0
  • 0
  • 0
  • 3.101
  • 0.3409
  • -0.0003229
Output
  • 0
  • 0
  • 0.04665
  • 0
  • 0.04434
  • 0
  • 0
  • 0
  • 0.2634
  • 5.777E-7
  • -0.00004251
Output
  • 0
  • 0
  • 0.01374
  • 0
  • 0.03626
  • 0
  • 0
  • 0
  • 0.4046
  • 0.00003748
  • -0.0001042
Output
  • 0
  • 0
  • 0.2079
  • 0
  • 0.5485
  • 0
  • 0
  • 0
  • 6.121
  • 0.000567
  • -0.001576

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 600.4
  • 3.225
  • 18.4
  • 13.83
  • 0.1436
  • 1.505E+5
  • 0
  • 4.149
  • 0.5706
  • 0.863
  • -66.94
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.02322
  • 0.000003538
  • 0.000006716
  • 0.00002527
  • 2.497E-7
  • 0.05349
  • 0
  • 0.00000758
  • 4.181E-7
  • 3.803E-7
  • -0.001139
Acidification potential, Accumulated Exceedance (AP)
  • 0.4857
  • 0.0006393
  • 0.006158
  • 0.002629
  • 0.00004863
  • 42.59
  • 0
  • 0.0007887
  • 0.0003303
  • 0.0003342
  • -0.08163
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.6544
  • 0.00008505
  • 0.01332
  • 0.0003786
  • 1.076
  • 51.29
  • 0
  • 0.0001136
  • 0.0001065
  • 0.001731
  • -0.01734
Global Warming Potential - fossil fuels (GWP-fossil)
  • 49.36
  • 0.1986
  • 1.092
  • 0.9147
  • 0.01037
  • 7294
  • 0
  • 0.2744
  • 0.6726
  • 0.08827
  • -5.97
Global Warming Potential - total (GWP-total)
  • 48.79
  • 0.1987
  • 1.114
  • 0.9154
  • 1.087
  • 7362
  • 0
  • 0.2746
  • 0.6728
  • 0.0904
  • -6.049
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.08577
  • 0.00006049
  • 0.009125
  • 0.0003256
  • 0.000003394
  • 16.97
  • 0
  • 0.00009767
  • 0.0001016
  • 0.0003998
  • -0.06129
  • 49.83
  • 0.1987
  • 1.343
  • 0.9154
  • 0.01037
  • 7899
  • 0
  • 0.2746
  • 0.6727
  • 0.09419
  • -6.961
Eutrophication potential - freshwater (EP-freshwater)
  • 0.005238
  • 0.00000158
  • 0.00002979
  • 0.000007308
  • 8.446E-8
  • 0.7789
  • 0
  • 0.000002192
  • 0.000001715
  • 0.000002272
  • -0.0005338
Eutrophication potential - marine (EP-marine)
  • 0.06031
  • 0.00014
  • 0.00128
  • 0.0005202
  • 0.00001618
  • 5.405
  • 0
  • 0.000156
  • 0.0001002
  • 0.0001211
  • -0.00743
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.971
  • 0.001562
  • 0.01504
  • 0.005818
  • 0.0001741
  • 66.64
  • 0
  • 0.001745
  • 0.001064
  • 0.000956
  • -0.08722
Photochemical Ozone Creation Potential (POCP)
  • 0.2068
  • 0.0006132
  • 0.004061
  • 0.002229
  • 0.00005007
  • 16.9
  • 0
  • 0.0006686
  • 0.0002728
  • 0.0003712
  • -0.03063
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.000003253
  • 4.788E-8
  • 1.675E-7
  • 2.072E-7
  • 2.167E-9
  • 0.0006177
  • 0
  • 6.216E-8
  • 4.282E-9
  • 6.868E-9
  • -0.003699
Water (user) deprivation potential (WDP)
  • 2674
  • 2.473
  • 1189
  • 13.38
  • 0.183
  • 2.263E+6
  • 0
  • 4.013
  • 5.066
  • 8.969
  • -1652

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 1.96
  • 0.0141
  • 0.1732
  • 0.06045
  • 0.0006146
  • 1318
  • 0
  • 0.01814
  • 0.002665
  • 0.003111
  • -0.1994
Potential incidence of disease due to PM emissions (PM) 2
  • 0.000003729
  • 1.824E-8
  • 8.508E-8
  • 5.6E-8
  • 7.17E-10
  • 0.0001117
  • 0
  • 1.68E-8
  • 1.934E-9
  • 6.023E-9
  • -5.142E-7
Potential Soil quality index (SQP) 2
  • 236.4
  • 3.697
  • 45.37
  • 9.674
  • 0.09674
  • 3.634E+4
  • 0
  • 2.902
  • 0.132
  • 2.017
  • -13.89
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000002431
  • 2.27E-9
  • 1.277E-8
  • 1.12E-8
  • 2.4E-10
  • 0.0001016
  • 0
  • 3.36E-9
  • 4.45E-8
  • 1.901E-9
  • -2.258E-8
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.511E-7
  • 0
  • 8.69E-10
  • 0
  • 5E-12
  • 0.000002941
  • 0
  • 0
  • 7.59E-10
  • 2.19E-10
  • -2.016E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 3616
  • 2.358
  • 21.31
  • 10.25
  • 0.1917
  • 1.054E+5
  • 0
  • 3.076
  • 2.174
  • 584.7
  • -533.4