Close Go back Collapse all sections
Process Data set: Tripar Medico (en) en

Key Data Set Information
Location DK
Geographical representativeness description Nordic + Northwestern Europe.
Reference year 2024
Name
Tripar Medico
Technical purpose of product or process Tripar Medico have the unique combination of comfortable and glare-free lighting, as well as all the benefits of LED lighting such as energy efficiency, long service life, good light quality, etc. Is particularly well suited to lighting on wards and in corridors etc. in hospitals. Mounting: Recessed, Indoor. Module: 600x600 Exposed T-carrier 15/24mm. Connection: 5 pol Winsta.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) can be excluded. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.308842592617 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-12-16" - "2029-12-16"
Technological representativeness
Technology description including background system Declaration data: Standards: EN 60598-1:2021+A11:2022 EN 60598-2-2:2012 EN 62471:2008 EN 62493:2015 EN 55015:2019+A11:2020 EN 61000-3-2:2019 EN 61000-3-3:2013+A1:2019 EN 61547:2009 Product data: Wattage: 32W. Voltage: 220-240V. Luminous flux: 3400lm. Colour temperature: 4000K. Colour rendering: Ra>90. Control/Dimming type: CD-DA. Housing: Sheet steel. Colour: White (Pure white, 25% gloss). Length: 595mm. Width: 595mm. Height: 110mm. Article number: 7141001123. Please note that the above has been calculated with the Norwegian Energy-mix. If you want an EPD with a specific energy-mix, please send us a request.

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 49.25
  • 0.0265
  • 33.22
  • 0.3366
  • 0.002485
  • 4.69E+3
  • 0
  • 0.05609
  • 0.403
  • 0.1235
  • -2.607
Input
  • 5.47
  • 0
  • 0
  • 0
  • -5.471
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 54.72
  • 0.0265
  • 33.22
  • 0.3366
  • -5.468
  • 4.69E+3
  • 0
  • 0.05609
  • 0.403
  • 0.1235
  • -2.607
Input
  • 482.6
  • 1.851
  • 33.74
  • 23.51
  • 0.151
  • 362.7
  • 0
  • 3.919
  • 2.413
  • 0.5857
  • -15.73
Input
  • 10.56
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -11.87
  • 0
  • 0
Input
  • 493.2
  • 1.851
  • 33.74
  • 23.51
  • 0.151
  • 362.7
  • 0
  • 3.919
  • -9.46
  • 0.5857
  • -15.73
Input
  • 2.993
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.001986
  • 0.009415
Input
  • 1.25
  • 0.0009482
  • 0.8376
  • 0.01204
  • 0.00008243
  • 3.683
  • 0
  • 0.002007
  • 0.008308
  • 0.001128
  • 0.02229
Input
  • 6.723
  • 0.00339
  • 0.768
  • 0.04305
  • 0.0003398
  • 9.176
  • 0
  • 0.007176
  • -0.00005957
  • 0.01872
  • 0.5283
Input
  • 0.4074
  • 0.000198
  • 0.09057
  • 0.002514
  • 0.00007123
  • 35.03
  • 0
  • 0.0004191
  • 0.00241
  • 0.00063
  • -0.009136
Output
  • 0.251
  • 0.00009548
  • 0.02391
  • 0.001213
  • 0
  • 0.2325
  • 0
  • 0.0002021
  • 0.00002856
  • 0.1229
  • -0.007449
Output
  • 7.768
  • 0.09004
  • 2.35
  • 1.143
  • 0.6671
  • 27.9
  • 0
  • 0.1906
  • 0.2123
  • 1.002
  • -0.3783
Output
  • 0.001599
  • 0.00001261
  • 0.00009524
  • 0.0001602
  • 0
  • 0.003243
  • 0
  • 0.00002669
  • 0.000001447
  • 0.000002106
  • -0.00003085
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 2.302
  • 0
  • 0.6205
  • 0
  • 0
  • 0
  • 3.173
  • 0.00001216
  • -0.0003684
Output
  • 0
  • 0
  • 0.1189
  • 0
  • 0.04664
  • 0
  • 0
  • 0
  • 0.3091
  • 2.974E-7
  • -0.00004851
Output
  • 0
  • 0
  • 0.0789
  • 0
  • 0.03816
  • 0
  • 0
  • 0
  • 0.2085
  • 0.00001929
  • -0.0001189
Output
  • 0
  • 0
  • 1.194
  • 0
  • 0.5773
  • 0
  • 0
  • 0
  • 3.154
  • 0.0002919
  • -0.001798

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 492.6
  • 1.851
  • 33.74
  • 23.51
  • 0.151
  • 362.1
  • 0
  • 3.919
  • 2.413
  • 0.5854
  • -15.73
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.005101
  • 0.000003382
  • 0.00001953
  • 0.00004295
  • 2.627E-7
  • 0.001978
  • 0
  • 0.000007159
  • 0.000001874
  • 2.374E-7
  • -0.001423
Acidification potential, Accumulated Exceedance (AP)
  • 0.2614
  • 0.0003519
  • 0.009585
  • 0.004469
  • 0.0000511
  • 0.2073
  • 0
  • 0.0007448
  • 0.0009357
  • 0.0002221
  • -0.06701
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.75
  • 0.00005068
  • 0.1326
  • 0.0006436
  • 1.132
  • 0.7334
  • 0
  • 0.0001073
  • 0.001125
  • 0.00002426
  • -0.002457
Global Warming Potential - fossil fuels (GWP-fossil)
  • 37.79
  • 0.1224
  • 2.555
  • 1.555
  • 0.01079
  • 26.53
  • 0
  • 0.2592
  • 0.7794
  • 0.0612
  • -1.418
Global Warming Potential - total (GWP-total)
  • 37.1
  • 0.1225
  • 2.695
  • 1.556
  • 1.143
  • 27.37
  • 0
  • 0.2594
  • 0.7808
  • 0.06141
  • -1.42
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.05702
  • 0.00004358
  • 0.0077
  • 0.0005535
  • 0.000003569
  • 0.1094
  • 0
  • 0.00009224
  • 0.0002791
  • 0.0001796
  • 0.00052
  • 38.2
  • 0.1225
  • 3.362
  • 1.556
  • 0.0108
  • 27.32
  • 0
  • 0.2594
  • 0.7807
  • 0.06416
  • -1.703
Eutrophication potential - freshwater (EP-freshwater)
  • 0.004276
  • 9.783E-7
  • 0.0001765
  • 0.00001242
  • 8.86E-8
  • 0.001908
  • 0
  • 0.000002071
  • 0.00001187
  • 0.000001241
  • -0.0003996
Eutrophication potential - marine (EP-marine)
  • 0.04086
  • 0.00006963
  • 0.001886
  • 0.0008843
  • 0.0000169
  • 0.02278
  • 0
  • 0.0001474
  • 0.000204
  • 0.00007852
  • -0.003765
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.454
  • 0.0007788
  • 0.02483
  • 0.009891
  • 0.000183
  • 0.2966
  • 0
  • 0.001648
  • 0.002267
  • 0.0006954
  • -0.05038
Photochemical Ozone Creation Potential (POCP)
  • 0.1551
  • 0.0002984
  • 0.005717
  • 0.003789
  • 0.0000526
  • 0.07975
  • 0
  • 0.0006315
  • 0.0006217
  • 0.000241
  • -0.0154
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.000002953
  • 2.774E-8
  • 1.39E-7
  • 3.522E-7
  • 2.278E-9
  • 0.000001819
  • 0
  • 5.871E-8
  • 4.903E-8
  • 5.407E-9
  • -0.001331
Water (user) deprivation potential (WDP)
  • 2.06E+3
  • 1.791
  • 404.3
  • 22.74
  • 0.1913
  • 6.313E+4
  • 0
  • 3.79
  • 12.69
  • 9.179
  • 85.75

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 1.928
  • 0.008092
  • 0.1421
  • 0.1028
  • 0.0006459
  • 6.57
  • 0
  • 0.01713
  • 0.01125
  • 0.002664
  • -0.03633
Potential incidence of disease due to PM emissions (PM) 2
  • 0.000002281
  • 7.497E-9
  • 1.153E-7
  • 9.52E-8
  • 7.54E-10
  • 0.000001486
  • 0
  • 1.587E-8
  • 1.107E-8
  • 3.656E-9
  • -1.764E-7
Potential Soil quality index (SQP) 2
  • 186.4
  • 1.295
  • 56.88
  • 16.45
  • 0.1013
  • 182.4
  • 0
  • 2.741
  • 0.8107
  • 1.327
  • -11.66
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000002094
  • 1.501E-9
  • 4.168E-8
  • 1.904E-8
  • 2.53E-10
  • 0.000001855
  • 0
  • 3.173E-9
  • 6.04E-8
  • 1.426E-9
  • -1.478E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.078E-7
  • 0
  • 1.149E-9
  • 0
  • 6E-12
  • 7.875E-8
  • 0
  • 0
  • 1.363E-9
  • 1.21E-10
  • -5.335E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 2083
  • 1.372
  • 57.71
  • 17.43
  • 0.2013
  • 1.65E+3
  • 0
  • 2.905
  • 9.8
  • 509.1
  • -508.2