Close Go back Collapse all sections
Process Data set: FLEXITEST SWITCH – 10 POSITION (FT-1) (en) en

Key Data Set Information
Location CH
Geographical representativeness description Europe
Reference year 2024
Name
FLEXITEST SWITCH – 10 POSITION (FT-1)
Use advice for data set The life cycle assessment is a “cradle-to-grave” analysis, and the system boundaries are defined according to EN 50693, as required by the PCR EPDItaly007. For transparency reasons, the manufacturing stage is further divided into an upstream and core stage.
Technical purpose of product or process This Environmental Product Declaration is an “average EPD” which declares an average product as the reference product. According to the General Program Instructions of EPDNorge, the total environmental impacts do not vary more than ± 10 % between the declared products; however, variations may be greater for the other impact categories. The EPD covers the following devices of the FT-1 Switch Family, including related accessories and packaging: • 129A501G01 (FT1-001) • 129A514G01 (FT1-014) • 498A020G01 (FT1-073) • 9682A75G01 (FT1-890) The results associated to an additional device of the FT-1 Switch Family can be extrapolated according to the provided extrapolation rules. The extrapolation rules cover the following devices of the FT-1 Switch Family, including related accessories and packaging: • 991A15KG01 (FT1-15K) • S129A518G01 (FT1-S018) FT-1 switches are used at every level of the power distribution process, from generation to distribution, to perform tests on switchboard relays, meters, and instruments. This product allows for these tests to be conducted without taking relays out of service or accessing the relay wiring. General technical information of the products is presented below. Description FT1-001 FT1-014 FT-073 FT1-890 Config. FT-1 Test Switch 129A501G01 129A514G01 498A020G01 9682A75G01 Size Length .16 m .16 m .16 m .16 m Width .070 m 070 m .070 m .070 m Height .06 m .06 m .06 m .06 m Weight .79 kg .83 kg .85 kg .90 kg Ratings Rated voltage [kV] .60 kV .60 kV .60 kV .60 kV Rated current [A] 30 A 30 A 30 A 30 A Rated continuous current for 1 sec.[kA] .5 kA .5 kA .5 kA .5 kA The products are manufactured by ABB US located in Pinetops, NC. The manufacturing site is certified according to the following standards: • ISO/IEC 17025:2017 – Electrical Testing • ISO 9001:2015 – Quality Management System The constituent materials of the average FT-1 Switch are presented below. Type Material Weight [kg] Weight % Metals Brass 0.26 42.15% Steel, stainless 0.03 3.49% Copper 0.11 17.71% Bronze 0.02 4.53% Plastics Polycarbonate 0.20 25.60% Polyethylene 0.001 0.13% PBT Resin 0.04 6.21% Nylon 0.001 0.18% Total 0.77 100%
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Both primary and secondary data are used. The main sources for primary data are the bill of materials, technical drawings, and site-specific foreground data provided by ABB. For all processes for which primary data are not available, generic background data originating from the ecoinvent v3.9.1 database, with system model “allocation, cut-off by classification”, are used. The LCA software used for the calculations is SimaPro 9.5. The utility consumption and waste generation by ABB, in the core manufacturing stage, is allocated to the production of one reference product according to applicable rules. For the end-of-life allocation, the “Polluter Pays” principle is adopted according to what is defined in the CEN/TR 16970 standard. However, the potential benefits and avoided loads from recovery and recycling processes are not considered because it is not required by the PCR. According to PCR, the cut-off criteria can be set to a maximum of 2 % of the overall environmental impacts. In this LCA, stickers have been excluded as their weights are negligible. Process black oxide and phosphate conversion coating have also been excluded due to the model complexity and unavailability of data.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description 2024-12-31 - 2029-12-31
Technological representativeness

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Waste processing
C3
Input
  • 13.1
  • 0.00794
  • 0.0187
  • 0
  • 0.0709
Input
  • 1.16
  • 0
  • 0
  • 0
  • 0
Input
  • 14.2
  • 0.00794
  • 0.0187
  • 0
  • 0.0709
Input
  • 85.9
  • 0.624
  • 1.46
  • 0
  • 0.881
Input
  • 8.82
  • 0
  • 0
  • 0
  • 0
Input
  • 94.7
  • 0.624
  • 1.46
  • 0
  • 0.881
Input
  • 0.17
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.0377
  • 0.0000889
  • 0.00021
  • 0
  • 0.00053
Output
  • 0.00115
  • 0.00000403
  • 0.00000941
  • 0
  • 0.00000316
Output
  • 3
  • 0.0303
  • 0.076
  • 0
  • 0.572
Output
  • 0.00015
  • 1.26E-7
  • 2.97E-7
  • 0
  • 0.00000135
Output
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.0967
  • 0
  • 0.0845
  • 0
  • 0.101
Output
  • 0.000499
  • 0
  • 0.0013
  • 0
  • 0.0904
Output
  • 0
  • 0
  • 0.00293
  • 0
  • 0.177
Output
  • 0
  • 0
  • 0.00528
  • 0
  • 0.319

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Waste processing
C3
Abiotic depletion potential - fossil resources (ADPF)
  • 6.83E+4
  • 0.624
  • 1.46
  • 0
  • 0.881
Abiotic depletion potential - non-fossil resources (ADPE)
  • 1.08
  • 1.42E-7
  • 3.32E-7
  • 0
  • 4.19E-7
Acidification potential, Accumulated Exceedance (AP)
  • 93.6
  • 0.000194
  • 0.000453
  • 0
  • 0.00034
Global Warming Potential - biogenic (GWP-biogenic)
  • -297
  • 0.0000154
  • 0.0107
  • 0
  • 0.000753
Global Warming Potential - fossil fuels (GWP-fossil)
  • 5.37E+3
  • 0.0441
  • 0.103
  • 0
  • 0.155
Global Warming Potential - total (GWP-total)
  • 5.09E+3
  • 0.0441
  • 0.114
  • 0
  • 0.156
Global Warming Potential - land use and land use change (GWP-luluc)
  • 10.7
  • 0.000023
  • 0.0000539
  • 0
  • 0.0000919
No records found.
No records found.
No records found.
No records found.
No records found.
Eutrophication potential - freshwater (EP-freshwater)
  • 7.12
  • 0.00000358
  • 0.00000841
  • 0
  • 0.0000218
Eutrophication potential - marine (EP-marine)
  • 9.4
  • 0.0000711
  • 0.000177
  • 0
  • 0.000508
Eutrophication potential - terrestrial (EP-terrestrial)
  • 101
  • 0.00076
  • 0.00178
  • 0
  • 0.000925
Photochemical Ozone Creation Potential (POCP)
  • 31.1
  • 0.000261
  • 0.000612
  • 0
  • 0.000291
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.000144
  • 6.98E-10
  • 1.63E-9
  • 0
  • 8.12E-10
Water (user) deprivation potential (WDP)
  • 2.65E+3
  • 0.00275
  • 0.00651
  • 5.05E+4
  • 0.0162

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Waste processing
C3
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0
  • 0
  • 0
  • 0
  • 0
Potential incidence of disease due to PM emissions (PM) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Soil quality index (SQP) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 0
  • 0
  • 0
  • 0
  • 0