Close Go back Collapse all sections
Process Data set: Junction box IP65 (en) en

Key Data Set Information
Location CN
Geographical representativeness description Nordic + Northwestern Europe.
Reference year 2025
Name
Junction box IP65
Technical purpose of product or process Wall-mounted junction box IP65. 12 integrated membranes around the box and two in the bottom. Supplied without connection terminals. Voltage: Max500V. IP Class: IP65. Material: Polypropylen(PP). Colour: White (RAL 9003). Mounting: Indoor / Outdoor. Length (mm): 100. Width (mm): 100. Height (mm): 40. EAN: 7021987871011 . The EPD also covers the following products: EAN: 7021987871110 - IP65 TERMINAL BOX BLACK EAN: 7021987875019 - IP65 JUNCTION BOX 43X99 WHITE EAN: 7021987875118 - IP65 JUNCTION BOX 43X99 BLACK EAN: 7021987872018 - IP65 TERMINAL 85X85 BOX WHITE EAN: 7021987872117 - IP65 TERMINAL 85X85 BOX BLACK
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.014659325994 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-07-28 - 2030-07-28
Technological representativeness
Technology description including background system Link to product data on our website: https://www.sg-as.com/products/koblingsboks-ip65/78710/pdf/specification_78710.pdf

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 0.7723
  • 0.004771
  • 0.2848
  • 0.01046
  • 0.000119
  • 0
  • 0.001552
  • 0.0003203
  • 0.0005353
  • -0.5973
Input
  • 0.2706
  • 0
  • 0
  • 0
  • -0.2706
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 1.043
  • 0.004771
  • 0.2848
  • 0.01046
  • -0.2705
  • 0
  • 0.001552
  • 0.0003203
  • 0.0005353
  • -0.5973
Input
  • 5.874
  • 0.4216
  • 2.807
  • 0.9232
  • 0.007191
  • 0
  • 0.1084
  • 0.008989
  • 0.0114
  • 0.1185
Input
  • 3.639
  • 0
  • 0
  • 0
  • -0.009004
  • 0
  • 0
  • -3.63
  • 0
  • 0.169
Input
  • 9.513
  • 0.4216
  • 2.807
  • 0.9232
  • -0.001813
  • 0
  • 0.1084
  • -3.621
  • 0.0114
  • 0.2874
Input
  • 0.05954
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.04921
  • 0.00009332
  • 0.0001359
  • 0.0003376
  • 0.000003934
  • 0
  • 0.00005551
  • 0.000008184
  • 0.00001124
  • 0.0001834
Input
  • 0.00003845
  • 0.0007924
  • 0.001643
  • 0.001848
  • 0.00001615
  • 0
  • 0.0001985
  • 0
  • 0.000165
  • -0.03568
Input
  • 0.004437
  • 0.00004714
  • 0.002593
  • 0.00008031
  • 0.000003397
  • 0
  • 0.00001159
  • 0.00003548
  • 0.00001401
  • -0.0006188
Output
  • 0.001512
  • 0.0000381
  • 0.0004866
  • 0.00004682
  • 0
  • 0
  • 0.00000559
  • 0
  • 0.001045
  • 0.000001434
Output
  • 0.03675
  • 0.02024
  • 0.03389
  • 0.02909
  • 0.03168
  • 0
  • 0.005272
  • 0
  • 0.04762
  • -0.001999
Output
  • 0.00001149
  • 0.000002767
  • 0.000001776
  • 0.000006322
  • 0
  • 0
  • 7.384E-7
  • 0
  • 7.486E-8
  • -3.539E-7
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.05098
  • 0
  • 0.02938
  • 0
  • 0
  • 0.02062
  • 0.000004215
  • 0.000002869
Output
  • 0
  • 0
  • 0.009592
  • 0
  • 0.0007317
  • 0
  • 0
  • 0.04699
  • 1.031E-7
  • 0.00001243
Output
  • 0
  • 0
  • 0.01457
  • 0
  • 0.0018
  • 0
  • 0
  • 0.07596
  • 0.000006687
  • 0.0000217
Output
  • 0
  • 0
  • 0.2204
  • 0
  • 0.02723
  • 0
  • 0
  • 1.149
  • 0.0001012
  • 0.0003283

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 9.512
  • 0.4216
  • 2.807
  • 0.9231
  • 0.00719
  • 0
  • 0.1084
  • 0.008988
  • 0.0114
  • 0.2729
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.00001276
  • 7.654E-7
  • 8.595E-7
  • 0.000001262
  • 1.248E-8
  • 0
  • 1.98E-7
  • 5.342E-9
  • 3.927E-9
  • 2.032E-8
Acidification potential, Accumulated Exceedance (AP)
  • 0.002072
  • 0.00008535
  • 0.00167
  • 0.0009769
  • 0.000002431
  • 0
  • 0.0000206
  • 0.00001623
  • 0.000003875
  • -0.00002074
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.04723
  • 0.00001111
  • 0.00009586
  • 0.00002322
  • 0.05184
  • 0
  • 0.000002967
  • 0.000001163
  • 5.144E-7
  • 0.00003213
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.441
  • 0.02853
  • 0.3382
  • 0.06527
  • 0.0005258
  • 0
  • 0.007169
  • 0.1187
  • 0.005434
  • 0.00341
Global Warming Potential - total (GWP-total)
  • 0.3949
  • 0.02855
  • 0.3384
  • 0.0653
  • 0.05237
  • 0
  • 0.007175
  • 0.1187
  • 0.005435
  • 0.00321
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.001124
  • 0.00001043
  • 0.00004088
  • 0.0000322
  • 1.696E-7
  • 0
  • 0.000002552
  • 1.878E-7
  • 1.15E-7
  • -0.0002325
  • 0.4482
  • 0.02855
  • 0.3201
  • 0.0653
  • 0.000526
  • 0
  • 0.007174
  • 0.1187
  • 0.005454
  • 0.002648
Eutrophication potential - freshwater (EP-freshwater)
  • 0.00001597
  • 2.676E-7
  • 0.000006935
  • 4.245E-7
  • 4.214E-9
  • 0
  • 5.728E-8
  • 1.144E-8
  • 5.748E-9
  • -4.621E-7
Eutrophication potential - marine (EP-marine)
  • 0.0003889
  • 0.00001681
  • 0.0003425
  • 0.0002347
  • 8.162E-7
  • 0
  • 0.000004077
  • 0.000007763
  • 0.000006958
  • -0.00001246
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.004208
  • 0.0001879
  • 0.003772
  • 0.002614
  • 0.000008705
  • 0
  • 0.0000456
  • 0.00008316
  • 0.00001532
  • -0.0001331
Photochemical Ozone Creation Potential (POCP)
  • 0.002196
  • 0.00007037
  • 0.0009789
  • 0.0007079
  • 0.000002505
  • 0
  • 0.00001747
  • 0.00002001
  • 0.000005498
  • -0.00002343
Depletion potential of the stratospheric ozone layer (ODP)
  • 2.623E-8
  • 6.206E-9
  • 2.885E-9
  • 1.437E-8
  • 1.08E-10
  • 0
  • 1.624E-9
  • 1.13E-10
  • 1.54E-10
  • -0.0004969
Water (user) deprivation potential (WDP)
  • 3.03
  • 0.1375
  • 0.2684
  • 0.5938
  • 0.00927
  • 0
  • 0.1048
  • 0.03006
  • 0.09754
  • -0.9121

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.01231
  • 0.001752
  • 0.002013
  • 0.003994
  • 0.00003078
  • 0
  • 0.0004738
  • 0.0000171
  • 0.00005503
  • -0.0004408
Potential incidence of disease due to PM emissions (PM) 2
  • 1.859E-8
  • 1.845E-9
  • 2.248E-8
  • 2.378E-9
  • 3.5E-11
  • 0
  • 4.39E-10
  • 7.5E-11
  • 7.6E-11
  • -3.095E-9
Potential Soil quality index (SQP) 2
  • 1.74
  • 0.2889
  • 0.6023
  • 0.4523
  • 0.004898
  • 0
  • 0.07582
  • 0.00124
  • 0.04256
  • -0.6426
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 4.293E-9
  • 3.35E-10
  • 3.593E-9
  • 4.71E-10
  • 1.2E-11
  • 0
  • 8.8E-11
  • 1.25E-10
  • 1.1E-11
  • -4.47E-10
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.85E-10
  • 0
  • 8.2E-11
  • 0
  • 0
  • 0
  • 0
  • 4E-12
  • 0
  • -7E-12
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 23.3
  • 0.3418
  • 8.433
  • 0.634
  • 0.009563
  • 0
  • 0.08035
  • 0.04982
  • 0.01411
  • -0.4829