Close Go back Collapse all sections
Process Data set: GREENLine HF70 / H07Z1-K 70 (en) en

Key Data Set Information
Location SE
Geographical representativeness description Scandinavia
Reference year 2025
Name
GREENLine HF70 / H07Z1-K 70
Use advice for data set The analysis is a cradle-to-grave study made for 1 m of cable manufactured , installed and used indoors over the lifetime 30 years. Modules A1-A5 are included in the analysis. It includes the extraction and production of raw materials, transportation to the factory, the production process itself, transportation to market and installation of the product. Modules B1-B7 describe the use phase and are not declared for an indoor cable. C1-C4, D are mandatory modules which include end of life treatment of materials and the benefits from recycling.
Technical purpose of product or process GREENLine H05Z1-K/H07Z1-K is a 70°C HFFR insulated flexible conductor. Suitable for power supply in buildings and internal wiring in electrical cabinets, switchboards, motors and other electric equipment. Further information can be found at https://amokabel.com/
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.006890415589 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-04-24 - 2030-04-24
Technological representativeness
Technology description including background system Max conductor temperature: -30°C/+70°C Voltage Rating H05 U0/U: 300/500 V Voltage Rating H07 U0/U: 450/750 V CPR-class: 0,5mm²-6mm² - Dca- s2, d2, a1 CPR-class: 10mm²-400mm² - Dca- s1, d1, a1

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 9.768
  • 0.01074
  • 0.005345
  • 0.01563
  • 0.0002556
  • 0
  • 0.002147
  • 0.0002381
  • 0.01147
  • -2.705
Input
  • 0.2314
  • 0
  • 0
  • 0
  • -0.5168
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 9.999
  • 0.01074
  • 0.005345
  • 0.01563
  • -0.5165
  • 0
  • 0.002147
  • 0.0002381
  • 0.01147
  • -2.705
Input
  • 43.12
  • 0.7506
  • 0.02662
  • 1.092
  • 0.01244
  • 0
  • 0.15
  • 0.0081
  • 0.08871
  • -5.308
Input
  • 4.519
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -3.486
  • 0
  • 0
Input
  • 47.64
  • 0.7506
  • 0.02662
  • 1.092
  • 0.01244
  • 0
  • 0.15
  • -3.478
  • 0.08871
  • -5.308
Input
  • 0.114
  • 0
  • 0.000001123
  • 0
  • 0.02267
  • 0
  • 0
  • 0
  • 0
  • 0.1706
Input
  • 0.2748
  • 0.0003844
  • 0.00002835
  • 0.0005593
  • 0.000007455
  • 0
  • 0.00007681
  • 0.00000671
  • 0.0002379
  • 0.01612
Input
  • 0.008864
  • 0.001374
  • 0.00009363
  • 0.002
  • 0.00008491
  • 0
  • 0.0002746
  • 0
  • 0.0001619
  • -0.001524
Input
  • 0.06013
  • 0.00008027
  • 0.00001753
  • 0.0001168
  • 0.000009056
  • 0
  • 0.00001604
  • 0.00002288
  • 0.0001154
  • -0.01501
Output
  • 0.04583
  • 0.00003871
  • 0.000205
  • 0.00005633
  • 0
  • 0
  • 0.000007735
  • 0
  • 0.01012
  • -0.006611
Output
  • 1.268
  • 0.0365
  • 0.06574
  • 0.05311
  • 0.03933
  • 0
  • 0.007294
  • 0
  • 0.2824
  • -0.2834
Output
  • 0.0001915
  • 0.000005113
  • 1.711E-7
  • 0.00000744
  • 0
  • 0
  • 0.000001022
  • 0
  • 6.154E-7
  • -0.000006378
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.06974
  • 0
  • 9.305E-7
  • 0
  • 0
  • 0.3558
  • 0.000003682
  • -0.006678
Output
  • 0
  • 0
  • 0.001732
  • 0
  • 0.03933
  • 0
  • 0
  • 0.04104
  • 9.004E-8
  • -0.0008793
Output
  • 0
  • 0
  • 0.002352
  • 0
  • 0.02735
  • 0
  • 0
  • 0.07959
  • 0.000005841
  • -0.002154
Output
  • 0
  • 0
  • 0.03559
  • 0
  • 0.4138
  • 0
  • 0
  • 1.204
  • 0.00008837
  • -0.03259

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 46.48
  • 0.7506
  • 0.0266
  • 1.092
  • 0.01244
  • 0
  • 0.15
  • 0.008099
  • 0.08871
  • -5.309
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.00135
  • 0.000001371
  • 3.166E-8
  • 0.000001995
  • 1.716E-8
  • 0
  • 2.74E-7
  • 4.334E-9
  • 2.946E-8
  • -0.0005486
Acidification potential, Accumulated Exceedance (AP)
  • 0.1525
  • 0.0001427
  • 0.000005638
  • 0.0002076
  • 0.00000851
  • 0
  • 0.00002851
  • 0.0000155
  • 0.0000299
  • -0.09799
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.04248
  • 0.00002055
  • 0.00009179
  • 0.0000299
  • 0.05637
  • 0
  • 0.000004105
  • 0.000001001
  • 4.601E-7
  • -0.002726
Global Warming Potential - fossil fuels (GWP-fossil)
  • 3.146
  • 0.04964
  • 0.004431
  • 0.07223
  • 0.001058
  • 0
  • 0.009919
  • 0.1238
  • 0.008174
  • -0.5901
Global Warming Potential - total (GWP-total)
  • 3.192
  • 0.04968
  • 0.004529
  • 0.07229
  • 0.05743
  • 0
  • 0.009926
  • 0.1238
  • 0.008176
  • -0.5937
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.003389
  • 0.00001767
  • 0.000006245
  • 0.00002571
  • 2.715E-7
  • 0
  • 0.00000353
  • 1.47E-7
  • 0.000001429
  • -0.000856
  • 3.203
  • 0.04968
  • 0.004517
  • 0.07229
  • 0.001059
  • 0
  • 0.009926
  • 0.1238
  • 0.008863
  • -0.2838
Eutrophication potential - freshwater (EP-freshwater)
  • 0.001246
  • 3.966E-7
  • 1.57E-8
  • 5.771E-7
  • 1.269E-8
  • 0
  • 7.925E-8
  • 9.492E-9
  • 6.705E-8
  • -0.0006606
Eutrophication potential - marine (EP-marine)
  • 0.009835
  • 0.00002823
  • 0.000001891
  • 0.00004108
  • 0.000003652
  • 0
  • 0.00000564
  • 0.000007443
  • 0.00001557
  • -0.004041
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.1453
  • 0.0003157
  • 0.0000192
  • 0.0004594
  • 0.00003911
  • 0
  • 0.00006309
  • 0.00008051
  • 0.0001203
  • -0.06257
Photochemical Ozone Creation Potential (POCP)
  • 0.0371
  • 0.000121
  • 0.000005532
  • 0.000176
  • 0.00001005
  • 0
  • 0.00002417
  • 0.00001927
  • 0.00003506
  • -0.017
Depletion potential of the stratospheric ozone layer (ODP)
  • 2.576E-7
  • 1.124E-8
  • 2.85E-10
  • 1.636E-8
  • 1.69E-10
  • 0
  • 2.247E-9
  • 9.5E-11
  • 1.088E-9
  • -0.0005086
Water (user) deprivation potential (WDP)
  • 240.7
  • 0.726
  • 1.095
  • 1.056
  • 0.01915
  • 0
  • 0.1451
  • 0.01834
  • 2.123
  • 30.68

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.2089
  • 0.003281
  • 0.0004321
  • 0.004774
  • 0.00004509
  • 0
  • 0.0006555
  • 0.00001369
  • 0.0005757
  • -0.007109
Potential incidence of disease due to PM emissions (PM) 2
  • 4.082E-7
  • 3.038E-9
  • 8E-11
  • 4.422E-9
  • 1.04E-10
  • 0
  • 6.07E-10
  • 6.1E-11
  • 5.24E-10
  • -1.993E-7
Potential Soil quality index (SQP) 2
  • 35.25
  • 0.525
  • 0.01564
  • 0.7639
  • 0.006973
  • 0
  • 0.1049
  • 0.0009827
  • 0.1738
  • -12.1
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000002448
  • 6.07E-10
  • 2.9E-11
  • 8.84E-10
  • 7.6E-11
  • 0
  • 1.21E-10
  • 1.04E-10
  • 1.28E-10
  • -0.00000109
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 3.196E-8
  • 0
  • 0
  • 0
  • 2E-12
  • 0
  • 0
  • 3E-12
  • 7E-12
  • -1.272E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 1813
  • 0.5564
  • 0.02517
  • 0.8096
  • 0.01416
  • 0
  • 0.1112
  • 0.02418
  • 146.9
  • -901.3