Close Go back Collapse all sections
Process Data set: ROCOR NB LIQUID 25 LTR (en) en

Key Data Set Information
Location NO
Geographical representativeness description Global maritime market
Reference year 2025
Name
ROCOR NB LIQUID 25 LTR
Use advice for data set This EPD covers the life cycle modules A1–A3 (raw material extraction, transport to factory, and production), module A4 (transport to storage and further to Norwegian port and Rotterdam). In addition, it includes module A5 (waste treatment of packaging), module C3 (product waste processing/biogenic carbon) and module D (reuse, recovery, recycling of potential of waste). In cases where the product does not contain biogenic carbon, the data in module C3 will be zero. The system boundaries are defined according to EN 15804+A2.
Technical purpose of product or process Rocor NB Liquid is a corrosion inhibitor formulated for cooling water systems. It contains a blend of active components that provide protection for ferrous and non-ferrous metals commonly present in engine cooling circuits. • Approved by major diesel engine manufacturers • Liquid product for accurate dosing and reduced handling • By forming an oxide film on the metal surfaces electrolytic corrosion is prevented • Effective against cavitation and erosion • Compatible with hoses, gaskets and seals • Compatible with glycols for frost protection • Simple control test
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 1.0 kg
  • Carbon content (biogenic) - packaging: 1.0 kg
Time representativeness
Data set valid until 2030
Technological representativeness
Technology description including background system Appearance: Red liquid Density (g/cm3): 1.1 Form: Liquid pH: 9.5 -10.5

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Waste processing
C3
Recycling Potential
D
Input
  • 1.912
  • 0.0208
  • 0.0009069
  • 0
  • -0.284
Input
  • 0.3588
  • 0
  • -0.3588
  • 0
  • -0.2318
Input
  • 2.271
  • 0.0208
  • -0.3579
  • 0
  • -0.5158
Input
  • 9.85
  • 0.7699
  • 0.02699
  • 0
  • -0.7352
Input
  • 1.964
  • 0
  • -1.882
  • -0.1052
  • -0.5762
Input
  • 11.81
  • 0.7699
  • -1.855
  • -0.1052
  • -1.311
Input
  • 0.002524
  • 0
  • 0
  • 0
  • 0
Input
  • 0.01243
  • 0.000001941
  • 4.489E-7
  • 0
  • -0.007883
Input
  • 0.0004268
  • 0
  • 0
  • 0
  • -5.164E-7
Input
  • -0.00364
  • 0.0001408
  • 0.00007258
  • 0
  • -0.0004851
Output
  • 0.04076
  • 0.00149
  • 0.0007819
  • 0
  • -0.002099
Output
  • 17.29
  • 0.03159
  • 0.06725
  • 0
  • -0.3453
Output
  • 0.05621
  • 0.00005215
  • 5.043E-9
  • 0
  • -0.000001474
Output
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.002375
  • 0
  • 0.02991
  • 0
  • 0
Output
  • 3.035E-8
  • 0
  • 5.47E-10
  • 0
  • 0
Output
  • 0.002864
  • 0
  • 0.000008801
  • 0
  • 0
Output
  • 0.000149
  • 0
  • 0.00001726
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Waste processing
C3
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 11.84
  • 0.7697
  • 0.02699
  • 0
  • -1.327
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.00002198
  • 1.037E-7
  • 7.814E-9
  • 0
  • -3.485E-7
Acidification potential, Accumulated Exceedance (AP)
  • 0.004004
  • 0.0004539
  • 0.00001802
  • 0
  • -0.0001725
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.01482
  • 0.00009961
  • 0.04101
  • 0
  • 0.02558
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.6863
  • 0.061
  • 0.06189
  • 0
  • -0.04663
Global Warming Potential - total (GWP-total)
  • 0.6722
  • 0.06116
  • 0.1029
  • 0
  • -0.02113
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0007574
  • 0.00005639
  • 6.707E-7
  • 0
  • -0.00008155
  • 0.6889
  • 0.06108
  • 0.0619
  • 0
  • -0.04677
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0002563
  • 0.000005014
  • 2.64E-7
  • 0
  • -0.00001488
Eutrophication potential - marine (EP-marine)
  • 0.001531
  • 0.0002011
  • 0.00001963
  • 0
  • -0.00003591
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.01062
  • 0.002199
  • 0.00008591
  • 0
  • -0.0003661
Photochemical Ozone Creation Potential (POCP)
  • 0.003226
  • 0.0006429
  • 0.00002407
  • 0
  • -0.000246
Depletion potential of the stratospheric ozone layer (ODP)
  • 1.928E-8
  • 1.217E-9
  • 4.5E-11
  • 0
  • -8.995E-9
Water (user) deprivation potential (WDP)
  • 0.8302
  • 0.004673
  • 0.004367
  • 0
  • -0.01808

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Waste processing
C3
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.08785
  • 0.001909
  • 0.00005673
  • 0
  • -0.008353
Potential incidence of disease due to PM emissions (PM) 2
  • 3.418E-8
  • 1.827E-9
  • 1.67E-10
  • 0
  • -1.506E-9
Potential Soil quality index (SQP) 2
  • 11.51
  • 0.5049
  • 0.01464
  • 0
  • -2.515
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 8.136E-9
  • 1.22E-10
  • 1.66E-10
  • 0
  • -4.12E-10
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.008E-9
  • 0
  • 3E-12
  • 0
  • -3.4E-11
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 7.066
  • 0.07945
  • 0.1319
  • 0
  • -0.1331