Schließen Zurück Alle Abschnitte einklappen
Prozess-Datensatz: Medium-voltage switchgear UniGear ZS1 12.12.32 IF, BT, LDU 650mm(w/CT, VT, CB) (de) en

Kerninformationen des Datensatzes
Referenzjahr 2025
Name
Medium-voltage switchgear UniGear ZS1 12.12.32 IF, BT, LDU 650mm(w/CT, VT, CB)
Anwendungshinweis für Datensatz The life cycle assessment is a “cradle-to-grave” analysis, and the system boundaries are defined according to EN 50693, as required by the PCR EPDItaly007. For transparency reasons, the manufacturing stage is further divided into an upstream and core stage.
Technisches Anwendungsgebiet Medium-voltage air-insulated switchgear UniGear ZS1 is the ABB mainline global switchgear up to 24 kV, 4000 A, 63 kA. UniGear ZS1 is used to distribute electric power in a variety of demanding applications such as on offshore platforms, in container or cruise ships, in mines as well as in utility substations, power plants or chemical plants. Panels are available as a single busbar, double busbar, back-to-back or double level solution.
Klassifizierung
Klassenname : Hierarchieebene
  • EPDNorge: Construction
Allgemeine Anmerkungen zum Datensatz Both primary and secondary data are used. The main sources for primary data are the bill of materials, technical drawings, and site-specific foreground data provided by ABB. For all processes for which primary data are not available, generic background data originating from the ecoinvent v3.9.1 database, with system model “allocation, cut-off by classification”, are used. The LCA software used for the calculations is SimaPro 9.5. The utility consumption and waste generation by ABB, in the core manufacturing stage, is allocated to the production of one reference product according to applicable rules. For the end-of-life allocation, the “Polluter Pays” principle is adopted according to what is defined in the CEN/TR 16970 standard. However, the potential benefits and avoided loads from recovery and recycling processes are not considered because it is not required by the PCR. According to PCR, the cut-off criteria can be set to a maximum of 2 % of the overall environmental impacts. In this LCA, stickers have been excluded as their weights are negligible. Process black oxide and phosphate conversion coating have also been excluded due to the model complexity and unavailability of data.
Copyright Ja
Eigentümer des Datensatzes
Quantitative Referenz
Referenzfluss(flüsse)
Biogener Kohlenstoffanteil
  • Innhold av biogent karbon i produkt: 0.0 kg
  • Innhold av biogent karbon i emballasjen: 0.0 kg
Zeitliche Repräsentativität
Datensatz gültig bis 2030
Erläuterungen zur zeitlichen Repräsentativität 2025-05-12 - 2030-05-12
Technologische Repräsentativität

Parameter zur Beschreibung des Ressourceneinsatzes und sonstige Umweltinformationen

IndikatorRichtungEinheit Herstellung
A1-A3
Transport
A4
Einbau
A5
Nutzung
B1
Abfallbehandlung
C3
Input
  • 1.05E+4
  • 11.9
  • 1.03
  • 4.86E+4
  • 70.5
Input
  • 2.67E+3
  • 0
  • 0
  • 0
  • 0
Input
  • 1.32E+4
  • 11.9
  • 1.03
  • 4.86E+4
  • 70.5
Input
  • 5.45E+4
  • 7.7E+2
  • 49
  • 2.61E+5
  • 804
Input
  • 1.07E+3
  • 0
  • 0
  • 0
  • 0
Input
  • 5.56E+4
  • 7.7E+2
  • 49
  • 2.61E+5
  • 804
Input
  • 177
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 54.3
  • 0.11
  • 0.00833
  • 199
  • 0.405
Output
  • 0.666
  • 0.0049
  • 0.000293
  • 0.332
  • 0.00316
Output
  • 1.02E+3
  • 37.6
  • 2.37
  • 714
  • 222
Output
  • 0.157
  • 0.00025
  • 0.0000208
  • 1.89
  • 0.00142
Output
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 484
  • 0
  • 157
  • 0
  • 509
Output
  • 21.1
  • 0
  • 0
  • 0
  • 1.5
Output
  • 43.1
  • 0
  • 0
  • 0
  • 4.53
Output
  • 85.7
  • 0
  • 0
  • 0
  • 8.16

IndikatorEinheit Herstellung
A1-A3
Transport
A4
Einbau
A5
Nutzung
B1
Abfallbehandlung
C3
Abiotisk utarmingspotensial for fossile ressurser, fosile brensler (ADP-fossil)
  • 5.41E+4
  • 7.7E+2
  • 49
  • 2.58E+5
  • 804
Abiotisk utarmingspotensial for ikke-fossile ressurser, mineraler (ADP-elements)
  • 0.809
  • 0.000174
  • 0.0000124
  • 0.0223
  • 0.00054
Forsurningspotensial for kilder på land og vann (AP)
  • 68.4
  • 0.223
  • 0.0141
  • 56.2
  • 0.317
Globalt oppvarmingspotensial - biogene kilder( GWP-biogenic)
  • -178
  • 0.0491
  • 252
  • 413
  • 50.4
Globalt oppvarmingspotensial - fossile brensler (GWP-fossil)
  • 4.34E+3
  • 54
  • 3.41
  • 1.12E+4
  • 71.4
Globalt oppvarmingspotensial -totalt (GWPtotal)
  • 4.16E+3
  • 54
  • 256
  • 1.16E+4
  • 122
Globalt oppvarmingspotensial arealbruk endringer i bruk av arealer (GWP-luluc)
  • 6.15
  • 0.0264
  • 0.00191
  • 28
  • 0.0811
No records found.
No records found.
No records found.
No records found.
No records found.
Overgjødslingspotensial til ferskvann (EP-freshwater)
  • 5.82
  • 0.0038
  • 0.000305
  • 10.2
  • 0.0211
Overgjødslingspotensial til hav (EP-marine), hav og jord
  • 6.87
  • 0.0852
  • 0.00524
  • 1E+1
  • 0.253
Overgjødslingspotensial til jord (EP-terrestrial)
  • 77.9
  • 0.91
  • 0.0555
  • 88.2
  • 0.862
Potensial for fotokjemisk oksidantdanning (POCP)
  • 23.1
  • 0.327
  • 0.02
  • 28.4
  • 0.285
Potensial for nedbryting av stratosfærisk ozon (ODP)
  • 0.000119
  • 0.00000118
  • 7.11E-8
  • 0.000201
  • 8.42E-7
Utarmingspotensial for vannressurser (WDP)
  • 1.44E+3
  • 3.13
  • 0.246
  • 2.63E+3
  • 11.4

IndikatorEinheit Herstellung
A1-A3
Transport
A4
Einbau
A5
Nutzung
B1
Abfallbehandlung
C3
1Diese Wirkungskategorie behandelt hauptsächlich die mögliche Wirkung einer ionisierenden Strahlung geringer Dosis auf die menschliche Gesundheit im Kernbrennstoffkreislauf. Sie berücksichtigt weder Auswirkungen, die auf mögliche nukleare Unfälle und berufsbedingte Exposition zurückzuführen sind, noch auf die Entsorgung radioaktiver Abfälle in unterirdischen Anlagen. Die potenzielle vom Boden, von Radon und von einigen Baustoffen ausgehende ionisierende Strahlung wird ebenfalls nicht von diesem Indikator gemessen.
2Die Ergebnisse dieses Umweltwirkungsindikators müssen mit Bedacht angewendet werden, da die Unsicherheiten bei diesen Ergebnissen hoch sind oder da es mit dem Indikator nur begrenzte Erfahrungen gibt.
Ioniserende stråling, helseeffekt (IRP) 1
  • 0
  • 0
  • 0
  • 0
  • 0
Partikkelutslipp (PM) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Påvirkninger knyttet til arealbruksendringer / jordkvalitet (SQP) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Toksisitet påvirkning på mennesker, andre effekter enn kreft (HTP-nc) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Toksisitet påvirkning på mennesker, kreft (HTP-c) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Økotoksisitet, ferskvann (ETP-fw) 2
  • 0
  • 0
  • 0
  • 0
  • 0