| Name |
|
| Technical purpose of product or process | ÖLFLEX ROBUST 215 C cables are screened control cables for flexible use and fixed installation for a robust mechanical use. They are also suitable for use in dry, damp or wet areas. They are suitable for outdoor use if the indicated temperature range is observed. At room temperature, they are increased resistant to the effects of acids, alkalis and oils, as well as greases and plant-, animal-, mineral- or synthetic-based waxes. They are suitable for constant use in fresh water to a depth of 10 m and at a maximum water temperature of 40°C acc. to EN 50565-2. The screening braid protects against interference from electrical fields. They are suitable for occasional, non-automated movements. The maximum tensile load is 15 N/mm² of conductor cross-section during installation and operation. Compulsory guidance is not permitted. All materials used are halogen-free. Application range ÖLFLEX ROBUST 215 C cables are used as flexible control cable in machine tool building, in medical technology, in laundries, in car washing equipment, in composting plants, in sewage, in submersible pumps and in EMC-sensitive environments (electromagnetic company). They are for use in the food and beverage industry, especially for production and processing equipment of milk and meat products. Design Based on EN 50525-2-51 Conductor Fine wire strands of bare copper, acc. to IEC 60228 resp. EN IEC 60228, class 5 Insulation Modified PP-compound Core identification code Acc. to VDE 0293, with or without GN/YE ground conductor Black cores with white numbers acc. to EN 50334 Wrapping Insulating foil of plastic Screen Braid of tinned copper, coverage = 85 % (nominal value) Outer sheath Special TPE--compound Colour: black, similar RAL 9005 |
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2031 |
| Time representativeness description | 2026 - 2031-03-03 |
| Technological representativeness | |
| Technology description including background system | Electrical properties at 20 °C Nominal voltage U₀ / U: 300 / 500 V Test voltage Core/Core: 4000 V AC Core/Screen: 2000 V AC Mechanical and thermal properties Minimum bending radius Occasional flexing: 12,5 x outer diameter Fixed installation: 6 x outer diameter Temperature range Occasional flexing: -40 °C up to +80 °C max. conductor temperature Fixed installation: -50 °C up to +80 °C max. conductor temperature UV resistance acc. to EN 50618 acc. to EN 50620 acc. to EN ISO 4892-2-2013, method A (change of colour allowed) Ozone resistance acc. to EN 50396, method B Oil resistance TM5 acc. to EN 50363-4-1 Water-resistance acc. to EN 50525-2-21 Tests acc. to IEC 60811 resp. EN 60811, EN 50395, EN 50396 General requirements These cables are conform to the EU-Directive 2014/35/EU (Low Voltage Directive) Environmental information These cables meet the substance-specific requirements of the EU Directive 2011/65/EU (RoHS) |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2026-03-03T17:21:23 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | d8c6b699-77d5-4d2f-8c79-13176d546ba8 |
| Date of last revision | 2026-03-02T15:11:57.0113555Z |
| Data set version | 00.02.002 |
| Registration authority | |
| Registration number | NEPD-15037-17695 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle