Close Go back Collapse all sections
Process Data set: Microtemp ETN5 (en) en

Key Data Set Information
Location NO
Geographical representativeness description Europe
Reference year 2024
Name
Microtemp ETN5
Technical purpose of product or process The range of thermostats from Function AS is designed to provide precise temperature control and customizable heating schedules for electric underfloor heating systems. With user-friendly interfaces and advanced features, the thermostats offer effortless programming options, allowing the user to create the perfect ambiance for any space. See more on https://function.no/ The declared products are OJ Electronics A/S standard products, of which 3 are sold by Function AS. Private labels may vary with regard to included sensors, instruction manuals, packaging, and other extra accessories. The main product components of the declared products are shown in the table below.
Classification
Class name : Hierarchy level
  • EPDNorge: Mutual Recognition EPDs from other program operators
General comment on data set This EPD is based on a cradle-to-grave LCA, in which 100 weight-% has been accounted for. The general rules for the exclusion of inputs and outputs follows the requirements in EN 15804, 6.3.5, where the total of neglected input flows per module shall be a maximum of 5 % of energy usage and mass and 1 % of energy usage and mass for unit processes.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0338 kg
Time representativeness
Data set valid until 2029
Time representativeness description 2024-12-18 - 2029-12-18
Technological representativeness

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 55.7
  • 0.021
  • 3.61
  • 0
  • 0
  • 0
  • 0
  • 0
  • 26
  • 0
  • 0
  • 0.000839
  • 0.107
  • 0.00124
  • -0.118
Input
  • 1.8
  • 0
  • -1.8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 57.5
  • 0.021
  • 0.00565
  • 0
  • 0
  • 0
  • 0
  • 0
  • 26
  • 0
  • 0
  • 0.000839
  • 0.107
  • 0.00124
  • -0.118
Input
  • 2.7E+2
  • 0.243
  • 0.0555
  • 0
  • 0
  • 0
  • 0
  • 0
  • 36
  • 0
  • 0
  • 0.00974
  • 0.149
  • 0.00715
  • -0.217
Input
  • 1.21
  • 0
  • -0.0165
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 262
  • 0.243
  • 0.0225
  • 0
  • 0
  • 0
  • 0
  • 0
  • 36
  • 0
  • 0
  • 0.00974
  • 0.149
  • 0.00715
  • -0.217
Input
  • 0.04
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.0983
  • 0.0000233
  • 0.000188
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0199
  • 0
  • 0
  • 9.35E-7
  • 0.0000817
  • 0.00000189
  • 0.000226
Output
  • 0.00000331
  • 9E-12
  • 1.1E-11
  • 0
  • 0
  • 0
  • 0
  • 0
  • 5.21E-8
  • 0
  • 0
  • 0
  • 2.13E-10
  • 2E-12
  • -2.5E-10
Output
  • 0.424
  • 0.0000397
  • 0.00205
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0297
  • 0
  • 0
  • 0.00000159
  • 0.000122
  • 0.0358
  • -0.000192
Output
  • 0.0077
  • 4.43E-7
  • 0.000001
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00576
  • 0
  • 0
  • 1.77E-8
  • 0.0000236
  • 7.55E-8
  • -0.0000273
Output
  • 0.00138
  • 0
  • 0.033
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.000819
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.133
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.0205
  • 0
  • 0.0978
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.0808
  • 0
  • 0.177
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 2.6E+2
  • 0.243
  • 0.0225
  • 0
  • 0
  • 0
  • 0
  • 0
  • 36
  • 0
  • 0
  • 0.00974
  • 0.149
  • 0.00715
  • -0.217
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0025
  • 1.61E-9
  • 1.1E-10
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.21E-7
  • 0
  • 0
  • 6.4E-11
  • 1.33E-9
  • 3.5E-11
  • 2.42E-8
Acidification potential, Accumulated Exceedance (AP)
  • 0.289
  • 0.0000287
  • 0.0000179
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00332
  • 0
  • 0
  • 0.00000115
  • 0.0000138
  • 0.00000382
  • 0.0000649
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.097
  • 0.0000441
  • 0.124
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0154
  • 0
  • 0
  • 0.00000177
  • 0.0000635
  • 0
  • -0.000051
Global Warming Potential - fossil fuels (GWP-fossil)
  • 17.9
  • 0.0185
  • 0.00245
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.72
  • 0
  • 0
  • 0.000739
  • 0.00718
  • 0.000539
  • 0.126
Global Warming Potential - total (GWP-total)
  • 17.7
  • 0.0188
  • 0.126
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.73
  • 0
  • 0
  • 0.000753
  • 0.00725
  • 0.000539
  • 0.125
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0174
  • 0.00031
  • 0.00000433
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000261
  • 0
  • 0
  • 0.0000124
  • 0.00000369
  • 0.00000321
  • 0.0000196
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
No records found.
Eutrophication potential - freshwater (EP-freshwater)
  • 0.00288
  • 7.89E-8
  • 3.35E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00000712
  • 0
  • 0
  • 3.16E-9
  • 2.98E-8
  • 6.77E-9
  • 0.00000256
Eutrophication potential - marine (EP-marine)
  • 0.0259
  • 0.000011
  • 0.00000656
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000828
  • 0
  • 0
  • 0.00000256
  • 0.00000348
  • 9.81E-7
  • 0.0000332
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.255
  • 0.000129
  • 0.0000819
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00867
  • 0
  • 0
  • 0.00000516
  • 0.0000365
  • 0.0000108
  • 0.000289
Photochemical Ozone Creation Potential (POCP)
  • 0.0771
  • 0.0000285
  • 0.0000174
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00219
  • 0
  • 0
  • 0.00000114
  • 0.0000092
  • 0.000003
  • 0.0000826
Depletion potential of the stratospheric ozone layer (ODP)
  • 3.9E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 3.9E-11
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.84E-10
Water (user) deprivation potential (WDP)
  • 3.41
  • 0.000286
  • 0.00797
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.475
  • 0
  • 0
  • 0.0000115
  • 0.00194
  • 0.0000619
  • 0.0115

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 1.2
  • 0.0000643
  • 0.000157
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.948
  • 0
  • 0
  • 0.00000257
  • 0.00388
  • 0.00000879
  • -0.00405
Potential incidence of disease due to PM emissions (PM) 2
  • 0.00000146
  • 3.12E-10
  • 1.01E-10
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.77E-8
  • 0
  • 0
  • 1.3E-11
  • 1.16E-10
  • 4.8E-11
  • 5.7E-10
Potential Soil quality index (SQP) 2
  • 1.5E+2
  • 0.12
  • 0.00732
  • 0
  • 0
  • 0
  • 0
  • 0
  • 15.2
  • 0
  • 0
  • 0.00479
  • 0.0631
  • 0.00195
  • 0.0157
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 3.31E-7
  • 1.64E-10
  • 1.4E-11
  • 0
  • 0
  • 0
  • 0
  • 0
  • 8.99E-9
  • 0
  • 0
  • 7E-12
  • 3.8E-11
  • 4E-12
  • 2.58E-9
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 6.37E-9
  • 4E-12
  • 1E-12
  • 0
  • 0
  • 0
  • 0
  • 0
  • 5.86E-10
  • 0
  • 0
  • 0
  • 2E-12
  • 0
  • 1.5E-11
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 138
  • 0.181
  • 0.0107
  • 0
  • 0
  • 0
  • 0
  • 0
  • 10.4
  • 0
  • 0
  • 0.00723
  • 0.0442
  • 0.005
  • 1.46