Close Go back Collapse all sections
Process Data set: PN 16/3G2,5 Easyfix (en) en

Key Data Set Information
Location NO
Geographical representativeness description Norway, Sweden, Denmark, Benelux, Finland, Baltics and Island
Reference year 2025
Name
PN 16/3G2,5 Easyfix
Use advice for data set Cradle to Gate. The following stages have been declared: A1-A4
Technical purpose of product or process Pre-wired corrugated, Halogen free pliable / self-recovering conduit acc. to EN 61386-1 and EN 61386-22. H07V-R insulated wire. The solution may be installed in open or closed environment, behind ceiling, in wall or below deck - embedded in concrete. Cable shall be used according to reference EN 50565-1 and EN 50565-2-6A/B. Contact with water is not permitted. Fire performance according to CPR EN 50575. The conduit material is a halogen free, flame retardant, self-extinguishing polypropylene with low toxic and smoke emission. Construction standard - Pipe: EN 611386-1; EN 61386-22 Pipe designation: ICTA 34423 Construction standard- Cable: EN 50525-1; EN 50525-2-31
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Data from material supplier and the LCA generator has been accepted "As-Is" Data from processing TECCON in-house has been repeated ongoingly without major deviations. Figures given in document are worst case values. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. The allocation is made in accordance with the guidelines given in EN 15804. Raw material - Information derived from manufactory and from a LCA generator Processing: Derived from actual measurements during production of the individual units/stages. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. All major materials have been included. Substance representing <1% have not been included. This include folio film for packaging!
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.001605504586 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-04-10 - 2030-04-10
Technological representativeness
Technology description including background system CONDUIT Construction standards EN 611386-1; EN 61386-22 ICTA 34423 Corrugated Conduit Pliable/Self recovering halogen free Polypropylene Compression force 750N Marking EN, Date, and meter marking: 0-100m Temperature - operation -25 to + 90°C Temperature - installation -5 to + 90°C Bending Radius 8 x D Resistant to fire performance Flame retardant, self-extinguishing, low smoke toxic emission Insulations resistance >100M? at 500V in 1 min Test - mechanical Acc. EN 61386-1; EN 61386-22 Test - electrical Acc. EN 61386-1; >2,0kV 50HZ in 15 min CABLE Construction standards EN 50525-1; EN 50525-2-31 Conductor Solid copper wire IEC 60228 Class 2 Insulation - conductor PVC TI 1 Conductor color - Cenelec G/G; Light Blue; Brown; Black; Whi- te; Orange; Dark Blue; Dark Blue; Red ; B/R and B/W Marking Wire: TECCON H07V-R; Packaging: acc. LVD Voltage - nominal Uo/U 450/750V Voltage - test 2kV Temperature classification 70° Temperature Max - Short circuit 250° Resistant to fire performance IEC 60332-1-2 CPR EN 50575 compliance Eca DoP 17_0001_00 Temperature - operation -5 - 70°C Temperature - installation 5 - 40°C Temperature - installed -30 to +70 CPR EN 50575 compliance Dca DOP 14150 Art.nr. 1251501

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 0.9423
  • 0.001302
  • 0.1326
  • 0.005449
  • 0.02262
  • 0
  • 0
  • 0.01605
  • 0.003303
  • -1.215
Input
  • 0.0957
  • 0
  • 0
  • 0
  • -0.09379
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 1.038
  • 0.001302
  • 0.1326
  • 0.005449
  • -0.07117
  • 0
  • 0
  • 0.01605
  • 0.003303
  • -1.215
Input
  • 7.248
  • 0.1157
  • 0.01092
  • 0.3807
  • 0.165
  • 0
  • 0
  • 0.1258
  • 0.03271
  • -1.554
Input
  • 0.7512
  • 0
  • 0
  • 0
  • -0.05176
  • 0
  • 0
  • -0.684
  • 0
  • 0
Input
  • 7.999
  • 0.1157
  • 0.01092
  • 0.3807
  • 0.1132
  • 0
  • 0
  • -0.5583
  • 0.03271
  • -1.554
Input
  • 0.01487
  • 0
  • 0
  • 0
  • 0.0003174
  • 0
  • 0
  • 0
  • 0.00003175
  • 0.04766
Input
  • 0.005977
  • 0.00004303
  • 0.0001045
  • 0.0001949
  • 0.0001383
  • 0
  • 0
  • 0.0002902
  • 0.0000749
  • 0.004399
Input
  • 0.01021
  • 0.0002332
  • 0.0002605
  • 0.000697
  • 0.0002447
  • 0
  • 0
  • 0
  • 0.0002741
  • -0.02564
Input
  • 0.01032
  • 0.000009805
  • 0.0009905
  • 0.00004071
  • 0.0002954
  • 0
  • 0
  • 0.003008
  • 0.00003559
  • -0.004964
Output
  • 0.006489
  • 0.000005546
  • 0.000006573
  • 0.00001963
  • 0.0001875
  • 0
  • 0
  • 0
  • 0.002333
  • -0.001851
Output
  • 0.1702
  • 0.003459
  • 0.003249
  • 0.01851
  • 0.01131
  • 0
  • 0
  • 0
  • 0.0597
  • -0.08099
Output
  • 0.0000155
  • 7.951E-7
  • 9.166E-8
  • 0.000002593
  • 3.971E-7
  • 0
  • 0
  • 0
  • 1.407E-7
  • -0.000002165
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.001843
  • 0
  • 0.009484
  • 0
  • 0
  • 0.0954
  • 0.000001485
  • -0.001865
Output
  • 0
  • 0
  • 6.3E-8
  • 0
  • 0.001199
  • 0
  • 0
  • 0.0477
  • 8.382E-7
  • -0.0002456
Output
  • 0
  • 0
  • 9.679E-8
  • 0
  • 0.001559
  • 0
  • 0
  • 0.0488
  • 0.000009395
  • -0.0006017
Output
  • 0
  • 0
  • 0.000001464
  • 0
  • 0.02359
  • 0
  • 0
  • 0.7383
  • 0.0001421
  • -0.009103

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 7.999
  • 0.1157
  • 0.0109
  • 0.3806
  • 0.1804
  • 0
  • 0
  • 0.1257
  • 0.03271
  • -1.554
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0001548
  • 1.531E-7
  • 5.691E-8
  • 6.954E-7
  • 0.000003213
  • 0
  • 0
  • 2.013E-7
  • 1.411E-8
  • -0.0001533
Acidification potential, Accumulated Exceedance (AP)
  • 0.05455
  • 0.0001322
  • 0.000006052
  • 0.00007235
  • 0.001129
  • 0
  • 0
  • 0.00005527
  • 0.00001308
  • -0.02741
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.006996
  • 0.000002894
  • 0.00002075
  • 0.00001042
  • 0.006113
  • 0
  • 0
  • 0.00003892
  • 0.000001615
  • -0.0007766
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.6207
  • 0.008223
  • 0.0008667
  • 0.02518
  • 0.0158
  • 0
  • 0
  • 0.09557
  • 0.00528
  • -0.1698
Global Warming Potential - total (GWP-total)
  • 0.6283
  • 0.008227
  • 0.0008905
  • 0.02519
  • 0.02193
  • 0
  • 0
  • 0.09561
  • 0.005282
  • -0.171
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0005375
  • 0.000004156
  • 0.000003107
  • 0.000008961
  • 0.0000116
  • 0
  • 0
  • 0.000007466
  • 5.799E-7
  • -0.0004053
  • 0.6332
  • 0.008227
  • 0.0007892
  • 0.02519
  • 0.01571
  • 0
  • 0
  • 0.09586
  • 0.005514
  • -0.08437
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0005339
  • 5.159E-8
  • 5.427E-8
  • 2.011E-7
  • 0.00001101
  • 0
  • 0
  • 2.814E-7
  • 5.279E-8
  • -0.0001849
Eutrophication potential - marine (EP-marine)
  • 0.00186
  • 0.00003186
  • 7.772E-7
  • 0.00001432
  • 0.00004012
  • 0
  • 0
  • 0.00001349
  • 0.000005995
  • -0.001142
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.02648
  • 0.0003548
  • 0.000009052
  • 0.0001601
  • 0.0005628
  • 0
  • 0
  • 0.0001447
  • 0.00004702
  • -0.01762
Photochemical Ozone Creation Potential (POCP)
  • 0.008367
  • 0.00009557
  • 0.000002469
  • 0.00006134
  • 0.0001775
  • 0
  • 0
  • 0.00004094
  • 0.00001328
  • -0.004786
Depletion potential of the stratospheric ozone layer (ODP)
  • 6.849E-8
  • 1.81E-9
  • 6.1E-11
  • 5.703E-9
  • 1.669E-9
  • 0
  • 0
  • 3.141E-9
  • 3.71E-10
  • -0.0004919
Water (user) deprivation potential (WDP)
  • 1.999
  • 0.07598
  • 1.786
  • 0.3682
  • 0.1547
  • 0
  • 0
  • 2.567
  • 0.6183
  • 7.242

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.01591
  • 0.000502
  • 0.0001887
  • 0.001664
  • 0.0004013
  • 0
  • 0
  • 0.000611
  • 0.0001868
  • -0.002473
Potential incidence of disease due to PM emissions (PM) 2
  • 9.984E-8
  • 2.78E-10
  • 4.5E-11
  • 1.541E-9
  • 2.115E-9
  • 0
  • 0
  • 3.59E-10
  • 1.63E-10
  • -5.806E-8
Potential Soil quality index (SQP) 2
  • 6.01
  • 0.05446
  • 0.00605
  • 0.2663
  • 0.1353
  • 0
  • 0
  • 0.0458
  • 0.0924
  • -3.839
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 8.772E-7
  • 5.6E-11
  • 5.2E-11
  • 3.08E-10
  • 1.81E-8
  • 0
  • 0
  • 1.419E-9
  • 1.24E-10
  • -3.048E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 9.893E-9
  • 0
  • 2E-12
  • 0
  • 2.04E-10
  • 0
  • 0
  • 1.3E-11
  • 4E-12
  • -3.56E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 412.1
  • 0.07832
  • 0.04722
  • 0.2822
  • 9.011
  • 0
  • 0
  • 6.026
  • 19.74
  • -252.1