Close Go back Collapse all sections
Process Data set: Retrofit mounting assembly for REX521RRP (en) en

Key Data Set Information
Location CH
Geographical representativeness description Europe
Reference year 2024
Name
Retrofit mounting assembly for REX521RRP
Use advice for data set The life cycle assessment is a “cradle-to-grave” analysis, and the system boundaries are defined according to EN 50693, as required by the PCR. For transparency reasons, the manufacturing stage is further divided into an upstream and core stage.
Technical purpose of product or process This Environmental Product Declaration is a “specific product EPD”, and the declared product is the Retrofit mounting assembly for REX521, including related packaging. Previous versions of REX521 relays are in the classic and obsolete stage of the product life cycle. ABB’s Relay Retrofit Program for REX 521 offers smooth and controlled replacement of REX 521 relays with REF615, REM615, REX615 from the Relion 615 series. The functionality of the selected 615 series relay corresponds to that of the existing REX521 relay. The main deliverables under this program are Relion 615 series replacement relay and the Retrofit mounting assembly for REX521RRP, which is prewired to the new Relion 615 relay for the customer. Retrofit mounting assembly can be installed in the existing panel door cutout after removal of REX521 relay. General technical specifications of the Retrofit mounting assembly for REX521RRP are presented below. Description Device Code 1 (Ref. product) Size Width 192 mm Height 268 mm Depth 183 mm Weight 2016 g ABB only performs assembly of the Retrofit mounting assembly for REX521RRP and a relay and the final testing of this retrofit assembly. ABB does not manufacture or assembly the Retrofit mounting assembly for REX521RRP itself. Instead, it is outsourced and purchased from supplier as a ready product. The assembly and testing are done at ABB Electrification service plant in Vaasa, Finland. The plant uses 100 % renewable energy for the electricity (50/50 mix of wind and hydro) and for heating (bioenergy). The plant is also certified according to the following standards: • ISO 9001:2015 – Quality Management Systems • ISO 14001:2015 – Environmental Management Systems • ISO 45001:2018 – Occupational Health and Safety Management Systems • ISO 50001:2018 – Energy management systems The constituent materials of the Retrofit mounting assembly for REX521RRP Reference Product are presented below. Type Material Weight [kg] Weight % Metals Steel, stainless 1.515 75.1 Other metals 0.011 0.6 Plastics and rubbers Polyamide 0.006 0.3 Rubber 0.010 0.5 Others Electronics 0.474 23.5 Total 2.016 100
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Both primary and secondary data are used. The main sources for primary data are the bill of materials (BOM), CAD-files, technical drawings, and site-specific foreground data provided by ABB. For all processes for which primary data are not available, generic background data originating from the ecoinvent v3.9.1 database, with system model “allocation, cut-off by classification”, are used. The LCA software used for the calculations is SimaPro 9.5. The utility consumption by ABB, in the core manufacturing stage, is allocated to the production of one reference product according to applicable rules. For the end-of-life allocation, the “Polluter Pays” principle is adopted according to what is defined in the CEN/TR 16970 standard, as required by EPDItaly007. However, the potential benefits and avoided loads from recovery and recycling processes are not considered because it is not required by the PCR. The PCR EPDItaly007 does not provide any details about cut-off criteria; it refers to chapter 4.2.3.3 in the standard EN 50693. According to EN 50693, the cut-off criteria can be set to a maximum of 5 % of the overall environmental impacts. In this LCA, labels as well as the tape and staples used in the packaging have been excluded as their weights are negligible.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description 2024-12-04 - 2029-12-04
Technological representativeness

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Waste processing
C3
Input
  • 1.35E+3
  • 0.0532
  • 0.0178
  • 0
  • 0.249
Input
  • 18.4
  • 0
  • 0
  • 0
  • 0
Input
  • 1.25E+3
  • 0.0532
  • 0.0178
  • 0
  • 0.249
Input
  • 234
  • 3.43
  • 0.522
  • 0
  • 2.48
Input
  • 17.5
  • 0
  • 0
  • 0
  • 0
Input
  • 252
  • 3.43
  • 0.522
  • 0
  • 2.48
Input
  • 1.65
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 1.08
  • 0.000488
  • 0.000399
  • 0
  • 0.00124
Output
  • 0.0124
  • 0.0000385
  • 0.00000575
  • 0.0056
  • 0.0000238
Output
  • 13
  • 0.295
  • 0.541
  • 12.1
  • 1.38
Output
  • 0.00245
  • 0.00000196
  • 3.71E-7
  • 0.0322
  • 0.0000105
Output
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.809
  • 0
  • 0.649
  • 0
  • 1.53
Output
  • 0.0675
  • 0
  • 0.119
  • 0
  • 0.0843
Output
  • 0
  • 0
  • 0.431
  • 0
  • 0.132
Output
  • 0
  • 0
  • 0.776
  • 0
  • 0.237

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Waste processing
C3
Abiotic depletion potential - fossil resources (ADPF)
  • 252
  • 3.43
  • 0.522
  • 0
  • 2.48
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.00387
  • 7.76E-7
  • 1.47E-7
  • 0
  • 0.00000173
Acidification potential, Accumulated Exceedance (AP)
  • 0.348
  • 0.000994
  • 0.00019
  • 0
  • 0.00108
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.0761
  • 0.000219
  • 0.222
  • 0
  • 0.0487
Global Warming Potential - fossil fuels (GWP-fossil)
  • 2E+1
  • 0.24
  • 0.169
  • 0
  • 0.455
Global Warming Potential - total (GWP-total)
  • 21.1
  • 0.24
  • 0.391
  • 0
  • 0.504
Global Warming Potential - land use and land use change (GWP-luluc)
  • 1.24
  • 0.000117
  • 0.0000263
  • 0
  • 0.000275
No records found.
No records found.
No records found.
No records found.
No records found.
Eutrophication potential - freshwater (EP-freshwater)
  • 0.022
  • 0.0000169
  • 0.00000509
  • 0
  • 0.0000697
Eutrophication potential - marine (EP-marine)
  • 0.0498
  • 0.000379
  • 0.000257
  • 0
  • 0.000361
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.862
  • 0.00405
  • 0.000719
  • 0
  • 0.00306
Photochemical Ozone Creation Potential (POCP)
  • 0.149
  • 0.00146
  • 0.000271
  • 0
  • 0.000909
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.00000294
  • 5.26E-9
  • 8.11E-10
  • 0
  • 2.43E-9
Water (user) deprivation potential (WDP)
  • 8.41
  • 0.0139
  • 0.0126
  • 0
  • 0.0325

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Waste processing
C3
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0
  • 0
  • 0
  • 0
  • 0
Potential incidence of disease due to PM emissions (PM) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Soil quality index (SQP) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 0
  • 0
  • 0
  • 0
  • 0