Close Go back Collapse all sections
Process Data set: F-R60 (en) en

Key Data Set Information
Location SK
Geographical representativeness description Europe.
Reference year 2024
Name
F-R60
Technical purpose of product or process The F-R60K fire damper is a fire protection device designed with compartmentalization to effectively prevent the spread of toxic gases, smoke, and fire. Its versatile design makes it suitable for various applications, including residential buildings, industrial facilities, hospitals, and more. The F-R60K fire dampers are available in various options and sizes. Specific EPD data is provided as a reference for the F-R60K-160-B230T model. Correction factors for other sizes can be estimated using the table in the Technical Data section below.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Ventilation components
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Energy, water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
  • - 1.0 * 1.0 Stück (Number of pieces)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-11-14" - "2029-11-14"
Technological representativeness
Technology description including background system Technical details can be found at the following link: https://design.systemair.com. To estimate the Global Warming Potential (GWPtot) correction factor for specific product size and type use the table below. For sizes not listed, calculate the correction factor using the provided equation. Each size has a specific correction factor. The correction factor is calculated by multiplying a coefficient by nominal diameter “DN” in millimeters and adding a constant. The equation for each type is as follows: F-R60 factor = 0,0044703 * DN + 0,4683979 F-R60K factor = 0,00462805 * DN + 0,296794 This equation enables you to estimate GWPtot correction factor for sizes not listed in the table. By using "DN" for your desired product size, you can calculate the GWPtot correction factor.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 19
  • 0.04488
  • 0.0003927
  • 0.00748
  • 1.203
  • 0.03494
  • -6.973
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 19
  • 0.04488
  • 0.0003927
  • 0.00748
  • 1.203
  • 0.03494
  • -6.973
Input
  • 167.6
  • 3.135
  • 0.07259
  • 0.5226
  • 6.636
  • 0.3266
  • -28.16
Input
  • 6.162
  • 0
  • 0
  • 0
  • -5.779
  • 0
  • 0
Input
  • 173.7
  • 3.135
  • 0.07259
  • 0.5226
  • 0.8572
  • 0.3266
  • -28.16
Input
  • 1.189
  • 0
  • 0.00003565
  • 0
  • 0.00001543
  • 0.000001383
  • 0.05987
Input
  • 0.4628
  • 0.001606
  • 0.00000966
  • 0.0002676
  • 0.02653
  • 0.0006402
  • 0.06116
Input
  • 2.118
  • 0.005741
  • 0.0001421
  • 0.0009569
  • 0.00001641
  • 0.006218
  • 1.663
Input
  • 0.2042
  • 0.0003353
  • 0.000003736
  • 0.00005588
  • 0.006238
  • 0.0005499
  • -0.03439
Output
  • 0.1217
  • 0.0001617
  • 0.000002137
  • 0.00002695
  • 0.000001789
  • 0.001334
  • -0.006327
Output
  • 3.993
  • 0.1525
  • 0.00008595
  • 0.02541
  • 0.7106
  • 0.4705
  • -1.045
Output
  • 0.000639
  • 0.00002136
  • 5.041E-7
  • 0.00000356
  • 1.814E-7
  • 6.629E-8
  • -0.00005068
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 1.274
  • 0
  • 0.000035
  • 0
  • 2.915
  • 0.000002573
  • -0.002343
Output
  • 0.06197
  • 0
  • 1.085E-7
  • 0
  • 0.7503
  • 7.088E-8
  • -0.0003085
Output
  • 0.03065
  • 0
  • 3.721E-7
  • 0
  • 0.06365
  • 0.000002243
  • -0.000756
Output
  • 0.4637
  • 0
  • 0.000005629
  • 0
  • 0.9629
  • 0.00003394
  • -0.01144

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 173.7
  • 3.135
  • 0.07259
  • 0.5225
  • 6.635
  • 0.3266
  • -28.17
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.005172
  • 0.000005728
  • 8.092E-9
  • 9.546E-7
  • 0.000005517
  • 1.152E-7
  • -0.0002184
Acidification potential, Accumulated Exceedance (AP)
  • 0.1744
  • 0.0005959
  • 0.00005517
  • 0.00009932
  • 0.002334
  • 0.0001325
  • -0.04917
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.04357
  • 0.00008583
  • 9.888E-7
  • 0.0000143
  • 0.003961
  • 0.00002517
  • -0.006491
Global Warming Potential - fossil fuels (GWP-fossil)
  • 12.4
  • 0.2074
  • 0.005274
  • 0.03456
  • 1.698
  • 0.06211
  • -2.813
Global Warming Potential - total (GWP-total)
  • 12.46
  • 0.2075
  • 0.005276
  • 0.03459
  • 1.703
  • 0.06214
  • -2.84
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.02061
  • 0.00007381
  • 4.157E-7
  • 0.0000123
  • 0.0003987
  • 0.000006055
  • -0.02034
  • 12.44
  • 0.2075
  • 0.005276
  • 0.03459
  • 1.703
  • 0.06214
  • -3.474
Eutrophication potential - freshwater (EP-freshwater)
  • 0.001312
  • 0.000001657
  • 1.92E-8
  • 2.761E-7
  • 0.00003786
  • 5.865E-7
  • -0.0003691
Eutrophication potential - marine (EP-marine)
  • 0.01497
  • 0.0001179
  • 0.00002435
  • 0.00001965
  • 0.0004861
  • 0.00003784
  • -0.003927
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.2931
  • 0.001319
  • 0.0002672
  • 0.0002198
  • 0.005475
  • 0.0004188
  • -0.04829
Photochemical Ozone Creation Potential (POCP)
  • 0.05581
  • 0.0005053
  • 0.00007347
  • 0.00008421
  • 0.001531
  • 0.0001176
  • -0.01717
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.000001047
  • 4.697E-8
  • 1.14E-9
  • 7.828E-9
  • 1.807E-7
  • 3.62E-9
  • -0.0004078
Water (user) deprivation potential (WDP)
  • 1914
  • 3.033
  • 0.01542
  • 0.5054
  • 26.57
  • 7.223
  • -487.2

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.7097
  • 0.0137
  • 0.0003111
  • 0.002284
  • 0.0304
  • 0.001762
  • -0.05305
Potential incidence of disease due to PM emissions (PM) 2
  • 0.000001074
  • 1.27E-8
  • 1.46E-9
  • 2.116E-9
  • 3.564E-8
  • 1.11E-9
  • -2.742E-7
Potential Soil quality index (SQP) 2
  • 50.73
  • 2.193
  • 0.009212
  • 0.3655
  • 2.624
  • 0.9681
  • -5.657
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000001817
  • 2.539E-9
  • 3.6E-11
  • 4.23E-10
  • 9.336E-9
  • 3.724E-8
  • -2.462E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 5.908E-8
  • 0
  • 0
  • 0
  • 1.515E-9
  • 5.63E-10
  • -1.469E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 1007
  • 2.324
  • 0.03967
  • 0.3874
  • 32.22
  • 6.466
  • -420.5