Process Data set: Ceiling Box (en) en

Key Data Set Information
Location CN
Geographical representativeness description Nordic + Northwestern Europe.
Reference year 2025
Name
Ceiling Box
Technical purpose of product or process Ceiling box to receive SG Install Lamp outlet. The ceiling box is also compatible with all types of lamp sockets, which are made for mounting in a Euro or PL box. The ceiling box has 6 airtight cable entries, and comes with a spalling cover as standard. Super easy and flexible mounting via the integrated angle bracket or the vertical screw holes. Can also be mounted on support iron (accessory). The ceiling box is available in 35 and 55 mm depth, and a spacer ring can also be purchased. Spacer for SG Install ceiling boxes. The ring is easily adjusted in height, by cutting it to the grooved 1 mm recesses. Support iron for mounting the SG Install ceiling box. IP Class: IP20. Material: PP/PC/TPE. Colour: Grey/black/white. Indoor. Length (mm): 190. Width (mm): 97. Height (mm): 58. EAN: 7021985919715. The EPD also covers the following products: EAN: 7021985919616 - PL CEILING BOX LOW 35 MM
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 9.52201257E-4 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-01-23 - 2030-01-23
Technological representativeness
Technology description including background system Declaration data: Standards: EN 60884-1:2013 (applies to plugs and fixed or portable socket-outlets for AC only, with or without earthing contact for household and similar purposes, either indoors or outdoors) Link to product data on our website: https://www.sg-as.com/da/produkter/loftdaser/7021985919715/pdf/specifikation_7021985919715.pdf

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 0.3307
  • 0.003642
  • 0.1843
  • 0.006785
  • 0.000007645
  • 0
  • 0.001007
  • 0.0002923
  • 0.0004626
  • -0.4567
Input
  • 0.01409
  • 0
  • 0
  • 0
  • -0.01409
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.3448
  • 0.003642
  • 0.1843
  • 0.006785
  • -0.01408
  • 0
  • 0.001007
  • 0.0002923
  • 0.0004626
  • -0.4567
Input
  • 4.965
  • 0.3218
  • 1.816
  • 0.5988
  • 0.0004644
  • 0
  • 0.07032
  • 0.007513
  • 0.009185
  • 0.03841
Input
  • 2.748
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -2.748
  • 0
  • 0.1181
Input
  • 7.713
  • 0.3218
  • 1.816
  • 0.5988
  • 0.0004644
  • 0
  • 0.07032
  • -2.74
  • 0.009185
  • 0.1565
Input
  • 0.0207
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.001342
  • 0.00007124
  • 0.0000887
  • 0.000219
  • 2.536E-7
  • 0
  • 0.00003601
  • 0.000007191
  • 0.000009689
  • 0.0002871
Input
  • 0.000009449
  • 0.0006049
  • 0.001067
  • 0.001199
  • 0.000001045
  • 0
  • 0.0001288
  • 0
  • 0.0001171
  • -0.02227
Input
  • 0.003338
  • 0.00003599
  • 0.001715
  • 0.0000521
  • 2.191E-7
  • 0
  • 0.00000752
  • 0.0000352
  • 0.00001132
  • -0.0004856
Output
  • 0.001082
  • 0.00002908
  • 0.0003139
  • 0.00003037
  • 0
  • 0
  • 0.000003626
  • 0
  • 0.0007727
  • -0.00002307
Output
  • 0.02972
  • 0.01545
  • 0.02189
  • 0.01887
  • 0.002052
  • 0
  • 0.00342
  • 0
  • 0.03812
  • -0.003406
Output
  • 0.000007336
  • 0.000002112
  • 0.00000115
  • 0.000004101
  • 0
  • 0
  • 4.79E-7
  • 0
  • 6.047E-8
  • -2.654E-7
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.03278
  • 0
  • 0.001909
  • 0
  • 0
  • 0.01857
  • 0.000003285
  • 0.000002005
Output
  • 0
  • 0
  • 0.006165
  • 0
  • 0.00001762
  • 0
  • 0
  • 0.03662
  • 8.034E-8
  • 0.000008685
Output
  • 0
  • 0
  • 0.009357
  • 0
  • 0.0001174
  • 0
  • 0
  • 0.0589
  • 0.000005212
  • 0.00001516
Output
  • 0
  • 0
  • 0.1416
  • 0
  • 0.001776
  • 0
  • 0
  • 0.891
  • 0.00007885
  • 0.0002294

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 7.713
  • 0.3218
  • 1.816
  • 0.5988
  • 0.0004644
  • 0
  • 0.07031
  • 0.007512
  • 0.009185
  • 0.1463
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.00000501
  • 5.843E-7
  • 5.57E-7
  • 8.186E-7
  • 8.08E-10
  • 0
  • 1.285E-7
  • 4.712E-9
  • 3.145E-9
  • -6.886E-8
Acidification potential, Accumulated Exceedance (AP)
  • 0.001759
  • 0.00006516
  • 0.00108
  • 0.0006337
  • 1.572E-7
  • 0
  • 0.00001336
  • 0.0000133
  • 0.000003118
  • -0.00004062
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.0003743
  • 0.000008482
  • 0.000063
  • 0.00001506
  • 0.003446
  • 0
  • 0.000001925
  • 0.000001007
  • 3.982E-7
  • 0.00001908
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.4144
  • 0.02178
  • 0.2187
  • 0.04234
  • 0.00003319
  • 0
  • 0.00465
  • 0.0919
  • 0.004245
  • -0.002604
Global Warming Potential - total (GWP-total)
  • 0.4143
  • 0.0218
  • 0.2188
  • 0.04236
  • 0.003479
  • 0
  • 0.004654
  • 0.0919
  • 0.004245
  • -0.002763
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0002806
  • 0.000007964
  • 0.00002652
  • 0.00002089
  • 1.098E-8
  • 0
  • 0.000001655
  • 1.675E-7
  • 9.468E-8
  • -0.0001786
  • 0.4175
  • 0.0218
  • 0.207
  • 0.04236
  • 0.00003321
  • 0
  • 0.004654
  • 0.09189
  • 0.004272
  • -0.005424
Eutrophication potential - freshwater (EP-freshwater)
  • 0.00001191
  • 2.043E-7
  • 0.000004488
  • 2.754E-7
  • 2.73E-10
  • 0
  • 3.715E-8
  • 9.725E-9
  • 4.681E-9
  • -6.41E-7
Eutrophication potential - marine (EP-marine)
  • 0.0003062
  • 0.00001283
  • 0.0002216
  • 0.0001523
  • 5.199E-8
  • 0
  • 0.000002644
  • 0.000006363
  • 0.000005459
  • -0.00001452
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.003391
  • 0.0001435
  • 0.00244
  • 0.001695
  • 5.628E-7
  • 0
  • 0.00002958
  • 0.00006773
  • 0.00001234
  • -0.0001531
Photochemical Ozone Creation Potential (POCP)
  • 0.001216
  • 0.00005372
  • 0.0006332
  • 0.0004592
  • 1.618E-7
  • 0
  • 0.00001133
  • 0.0000163
  • 0.0000044
  • -0.0000426
Depletion potential of the stratospheric ozone layer (ODP)
  • 1.611E-8
  • 4.737E-9
  • 1.875E-9
  • 9.322E-9
  • 7E-12
  • 0
  • 1.053E-9
  • 9.7E-11
  • 1.22E-10
  • -0.0003771
Water (user) deprivation potential (WDP)
  • 1.425
  • 0.1049
  • 0.1751
  • 0.3852
  • 0.0005885
  • 0
  • 0.06801
  • 0.02989
  • 0.08445
  • -0.473

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.008168
  • 0.001338
  • 0.001304
  • 0.002591
  • 0.000001987
  • 0
  • 0.0003073
  • 0.00001505
  • 0.00004498
  • -0.000329
Potential incidence of disease due to PM emissions (PM) 2
  • 2.076E-8
  • 1.407E-9
  • 1.455E-8
  • 1.543E-9
  • 2E-12
  • 0
  • 2.85E-10
  • 6.1E-11
  • 6.2E-11
  • -2.749E-9
Potential Soil quality index (SQP) 2
  • 1.172
  • 0.2205
  • 0.3896
  • 0.2934
  • 0.0003115
  • 0
  • 0.04918
  • 0.001091
  • 0.03364
  • -0.4911
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 5.204E-9
  • 2.55E-10
  • 2.326E-9
  • 3.05E-10
  • 1E-12
  • 0
  • 5.7E-11
  • 1.12E-10
  • 8E-12
  • 1.36E-10
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 2.66E-10
  • 0
  • 5.3E-11
  • 0
  • 0
  • 0
  • 0
  • 3E-12
  • 0
  • -2.7E-11
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 8.601
  • 0.2609
  • 5.455
  • 0.4113
  • 0.0006193
  • 0
  • 0.05212
  • 0.05374
  • 0.6548
  • -0.6245