Close Go back Collapse all sections
Process Data set: Indoor Current Sensor KECA 80 C85 (en) en

Key Data Set Information
Location CH
Geographical representativeness description Europe
Reference year 2024
Name
Indoor Current Sensor KECA 80 C85
Use advice for data set The life cycle assessment of the KECA 80 C85, an EEPS (Electronic and Electrical Products and Systems), is a “cradle-to-grave” analysis. The figure below shows the product life cycle stages and the information considered in the LCA.
Technical purpose of product or process The product declared in this Environmental Product Declaration is the indoor current sensor KECA 80 C85, including related accessories and packaging. Current sensors offer an alternative way of making the current measurement needed for the protection and monitoring of medium voltage power systems. Sensors based on alternative principles have been introduced as successors to conventional instrument transformers in order to significantly reduce size, increase safety, and to provide greater rating standardization and a wider functionality range. The construction is based on Rogowski coil principle. The current sensors have combined class for both measuring or protection purposes. The current sensors can be mounted in any position. The current sensors shall be fixed on insulated and shielded cables or other conductors. The constituent materials of KECA 80 C85 are presented below. Type Material Weight [kg] Weight [%] Metals Bronze 0.001 0.19 Copper 0.115 40.6 Plastics PA 0.015 5.25 PC 0.03 10.53 PP 0.092 32.69 PUR 0.010 3.63 Other polymers 0.009 3.10 Others Others 0.01 3.44 PUR WEVO 0.002 0.57 Total 0.283 100
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Both primary and secondary data are used. The main sources for primary data are the bill of materials and technical drawings, while site specific foreground data are provided by ABB. Furthermore, information and data obtained from other LCA studies are also used. For all processes for which primary data are not available, generic data originating from the ecoinvent v3.9.1 database, “allocation, cut-off by classification”, are used. The LCA software used for the calculations is SimaPro 9.5. The utility consumption and waste generation by ABB, in the core manufacturing stage, is allocated to the production of one reference product according to applicable rules. For the end-of-life allocation, the “Polluter Pays” principle is adopted according to what is defined in the CEN/TR 16970 standard. However, the potential benefits and avoided loads from recovery and recycling processes are not considered because it is not required by the PCR. The materials that were excluded are glue, and adhesive, as their mass represents less than 2% of that of the whole product, as stated in the paragraph of cut-off criteria of EPDItaly015: “Materials making up the sensor itself whose total mass does not exceed 2% of the total weight of the device”. The same applies for tape and labels used in packaging, which are even a smaller fraction of the total mass. Sandblasting of capacitors and phosphating were also excluded due to the model complexity and unavailability of reference data.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description 2024-10-17 - 2029-10-17
Technological representativeness
Technology description including background system General technical specifications of the product are presented below. Technical information Unit Value Outer height/width mm 116.5/25.5 Insulation level kV 0.82 Rated primary A from 80 up to 4 000 Accuracy class - 0.5/5P630 (IEC 60044-8) 0.5-A2/5P 85kA (IEC 61869-10) Frequency Hz 50 / 60 The production of the instrument sensors, from which medium indoor current sensor KECA 80 C85 is part of, is located in the ABB Brno Videnska factory. The instrument sensors are produced and assembled directly in the ABB factory combined with components produced by ABB’s suppliers. ABB Brno ELDS adopts and implements for its own activities an integrated Quality/Environmental/Health Management System in compliance with the following standards: • UNI EN ISO 9001:2015 - Quality Management Systems- Requirements • UNI EN ISO 14001:2015 - Environmental Management Systems • UNI EN ISO 45001:2018 - Occupational Health and Safety Management system

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Waste processing
C3
Input
  • 10.8
  • 0.00413
  • 0.000465
  • 0.102
  • 0.0163
Input
  • 0.739
  • 0
  • 0
  • 0
  • 0
Input
  • 11.5
  • 0.00413
  • 0.000465
  • 0.102
  • 0.0163
Input
  • 29.1
  • 0.266
  • 0.0214
  • 0.53
  • 0.227
Input
  • 6.32
  • 0
  • 0
  • 0
  • 0
Input
  • 35.5
  • 0.266
  • 0.0214
  • 0.53
  • 0.227
Input
  • 0.0252
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.0406
  • 0.0000379
  • 0.00000454
  • 0.000414
  • 0.000107
Output
  • 0.00131
  • 0.00000169
  • 1.24E-7
  • 6.71E-7
  • 0.00000101
Output
  • 0.527
  • 0.013
  • 0.0177
  • 0.00145
  • 0.165
Output
  • 0.0000476
  • 8.64E-8
  • 9.02E-9
  • 0.00000386
  • 3.32E-7
Output
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.0326
  • 0
  • 0.0196
  • 0
  • 0.125
Output
  • 0.0018
  • 0
  • 0.0132
  • 0
  • 0
Output
  • 0.0025
  • 0
  • 0.0308
  • 0
  • 0
Output
  • 0.00514
  • 0
  • 0.0554
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Waste processing
C3
Abiotic depletion potential - fossil resources (ADPF)
  • 49.3
  • 0.266
  • 0.0214
  • 0.53
  • 0.227
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.00129
  • 6.02E-8
  • 5.05E-9
  • 4.58E-8
  • 1.32E-7
Acidification potential, Accumulated Exceedance (AP)
  • 0.102
  • 0.0000771
  • 0.00000824
  • 0.000116
  • 0.0000859
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.175
  • 0.000017
  • 0.0208
  • 0.00085
  • 0.00791
Global Warming Potential - fossil fuels (GWP-fossil)
  • 3.05
  • 0.0186
  • 0.00267
  • 0.023
  • 0.0232
Global Warming Potential - total (GWP-total)
  • 2.87
  • 0.0187
  • 0.0235
  • 0.0239
  • 0.0311
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.00713
  • 0.00000911
  • 8.1E-7
  • 0.0000576
  • 0.0000194
No records found.
No records found.
No records found.
No records found.
No records found.
Eutrophication potential - freshwater (EP-freshwater)
  • 0.00796
  • 0.00000131
  • 2.31E-7
  • 0.000021
  • 0.00000477
Eutrophication potential - marine (EP-marine)
  • 0.00685
  • 0.0000294
  • 0.0000104
  • 0.0000206
  • 0.000127
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.0873
  • 0.000314
  • 0.000035
  • 0.000181
  • 0.000258
Photochemical Ozone Creation Potential (POCP)
  • 0.0262
  • 0.000113
  • 0.0000118
  • 0.0000584
  • 0.0000872
Depletion potential of the stratospheric ozone layer (ODP)
  • 1.08E-7
  • 4.08E-10
  • 3.1E-11
  • 4.14E-10
  • 2.49E-10
Water (user) deprivation potential (WDP)
  • 2.18
  • 0.00108
  • 0.000115
  • 0.00542
  • 0.00321

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Waste processing
C3
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0
  • 0
  • 0
  • 0
  • 0
Potential incidence of disease due to PM emissions (PM) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Soil quality index (SQP) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 0
  • 0
  • 0
  • 0
  • 0