Close Go back Collapse all sections
Process Data set: SCF (en) en

Key Data Set Information
Location DE
Geographical representativeness description Europe.
Reference year 2024
Name
SCF
Technical purpose of product or process Standard cell frames type SCF as a base element for mounting a filter wall in air handling units and ventilation systems. Fitting of filter elements for the separation of coarse and fine dust. For more information see: https://www.trox.de/en/standard-cell-frames/scf-9137f6374e64ce23 Standard cell frames type SCF as a base element for mounting a filter wall in air handling units and ventilation systems. Fitting of filter elements for the separation of coarse dust and fine dust and for the adsorption of gaseous odorous substances and contaminants. Standard cell frame available in various sizes with or without groove. Construction with groove and foamed continuous seal for various filter frame depths. For cut-to-size filter pads, the cell frames are equipped with support grid and press-in frame (without seal). Standard cell frame without perimeter groove, with either a foamed continuous seal or a profiled seal. Four clamping elements for secure sealing between the cell frame and the filter element. Standard cell frames meet the hygiene requirements of VDI 6022. This EPD declares the environmental data of the product series SCF. The following represents a representative dataset of the default variant SCF-B-25-GAL/610x610x80/CS.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Ventilation components
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Energy, water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
  • - 1.0 * 1.0 Stück (Number of pieces)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description 2024-12-04 - 2029-12-04
Technological representativeness
Technology description including background system For technical data see: https://www.trox.de/en/standard-cell-frames/scf-9137f6374e64ce23#technical-information

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 17.2
  • 0.07354
  • 0.0002356
  • 0.004596
  • 0.03777
  • 0.0202
  • -0.3727
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 17.2
  • 0.07354
  • 0.0002356
  • 0.004596
  • 0.03777
  • 0.0202
  • -0.3727
Input
  • 163.4
  • 5.137
  • 0.04356
  • 0.3211
  • 0.2093
  • 0.09426
  • -4.589
Input
  • 1.38
  • 0
  • 0
  • 0
  • -1.38
  • 0
  • 0
Input
  • 164.7
  • 5.137
  • 0.04356
  • 0.3211
  • -1.171
  • 0.09426
  • -4.589
Input
  • 1.773
  • 0
  • 0.00002139
  • 0
  • 0
  • 0.0004859
  • 0
Input
  • 1.325
  • 0.002631
  • 0.000005796
  • 0.0001644
  • 0.0008333
  • 0.00007068
  • 0.0197
Input
  • 4.418
  • 0.009407
  • 0.00008528
  • 0.0005879
  • 0
  • 0.004424
  • 0.5734
Input
  • 0.1408
  • 0.0005494
  • 0.000002242
  • 0.00003434
  • 0.0001938
  • 0.00008289
  • -0.001148
Output
  • 0.1747
  • 0.0002649
  • 0.000001282
  • 0.00001656
  • 0
  • 0.0225
  • -0.002835
Output
  • 4.241
  • 0.2498
  • 0.00005157
  • 0.01561
  • 0.0225
  • 0.2393
  • -0.2229
Output
  • 0.0006449
  • 0.00003499
  • 3.024E-7
  • 0.000002187
  • 0
  • 0
  • 0.000001504
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.7666
  • 0
  • 0.000021
  • 0
  • 2.115
  • 0
  • 0
Output
  • 0.2486
  • 0
  • 6.512E-8
  • 0
  • 0.0225
  • 0
  • 0
Output
  • 0.1477
  • 0
  • 2.233E-7
  • 0
  • 0.00002228
  • 0
  • 0
Output
  • 2.235
  • 0
  • 0.000003378
  • 0
  • 0.0003371
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 164.5
  • 5.137
  • 0.04355
  • 0.3211
  • 0.2092
  • 0.0942
  • -4.591
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.008473
  • 0.000009385
  • 4.855E-9
  • 5.866E-7
  • 1.742E-7
  • 3.986E-8
  • -0.000009412
Acidification potential, Accumulated Exceedance (AP)
  • 0.109
  • 0.0009764
  • 0.0000331
  • 0.00006103
  • 0.0000733
  • 0.00003606
  • -0.002711
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.2297
  • 0.0001406
  • 5.933E-7
  • 0.000008789
  • 0.0001252
  • 0.000005882
  • -0.0003009
Global Warming Potential - fossil fuels (GWP-fossil)
  • 12.11
  • 0.3398
  • 0.003165
  • 0.02123
  • 0.04987
  • 0.007675
  • -0.5454
Global Warming Potential - total (GWP-total)
  • 12.36
  • 0.34
  • 0.003165
  • 0.02125
  • 0.05001
  • 0.007724
  • -0.5459
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.01305
  • 0.0001209
  • 2.494E-7
  • 0.000007558
  • 0.00001259
  • 0.00004278
  • -0.0002445
  • 12.39
  • 0.34
  • 0.003165
  • 0.02125
  • 0.05
  • 0.007724
  • -0.8169
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0007718
  • 0.000002714
  • 1.152E-8
  • 1.696E-7
  • 0.000001197
  • 2.399E-7
  • -0.00003356
Eutrophication potential - marine (EP-marine)
  • 0.0136
  • 0.0001932
  • 0.00001461
  • 0.00001208
  • 0.00001515
  • 0.000009209
  • -0.000561
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.3564
  • 0.002161
  • 0.0001603
  • 0.0001351
  • 0.0001707
  • 0.0001007
  • -0.005734
Photochemical Ozone Creation Potential (POCP)
  • 0.04535
  • 0.0008278
  • 0.00004408
  • 0.00005174
  • 0.00004783
  • 0.00003865
  • -0.002733
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.000001093
  • 7.696E-8
  • 6.84E-10
  • 4.81E-9
  • 5.715E-9
  • 8.27E-10
  • -1.907E-7
Water (user) deprivation potential (WDP)
  • 943.2
  • 4.969
  • 0.009253
  • 0.3105
  • 0.775
  • 0.3451
  • 28.28

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.7105
  • 0.02245
  • 0.0001866
  • 0.001403
  • 0.0009522
  • 0.00027
  • 0.001958
Potential incidence of disease due to PM emissions (PM) 2
  • 0.000001081
  • 2.08E-8
  • 8.76E-10
  • 1.3E-9
  • 1.125E-9
  • 6.45E-10
  • -4.527E-8
Potential Soil quality index (SQP) 2
  • 68.49
  • 3.593
  • 0.005527
  • 0.2246
  • 0.08253
  • 0.2777
  • -0.3436
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 6.992E-7
  • 4.16E-9
  • 2.2E-11
  • 2.6E-10
  • 2.93E-10
  • 2.09E-10
  • 5.702E-8
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 5.89E-8
  • 0
  • 0
  • 0
  • 4.8E-11
  • 2.2E-11
  • -2.623E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 402
  • 3.808
  • 0.0238
  • 0.238
  • 1.015
  • 1.415
  • -30.4