Close Go back Collapse all sections
Process Data set: Protecta FR Collar (en) en

Key Data Set Information
Location GB
Geographical representativeness description Global. Transport to market is not included in this EPD.
Reference year 2024
Name
Protecta FR Collar
Use advice for data set The life cycle analysis is a cradle-to-gate (A1 - A3) study. It includes the extraction and production of raw materials and packaging, transportation to the manufacturing site, as well as the manufacturing process itself. A1: Wooden pallets and plastic wrapping are excluded because the product is shipped in boxes.
Technical purpose of product or process Protecta FR Collars are designed to maintain the fire resistance of fire rated walls and floors where these are breached by service penetrations, and may be used in drywalls, timber, masonry or concrete walls and floors. Each collar consists of a white or red coated circular steel shell that splits in two to fit around the service penetrations by means of a simple ’slide-lock’ system. The steel shell contains a graphite based reactive material which reacts when exposed to heat from fire closing the openings left by the softening combustible material.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Paint
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 1.0 kg
  • Carbon content (biogenic) - packaging: 1.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-09-17" - "2029-09-17"
Technological representativeness
Technology description including background system The product has third-party verified ETAs and UKTAs issued in accordance with regulation (EU) No 305/2011 on the basis of EAD 350454-00-1104, tested to EN 1366-3, in conjunction with EN 1363-1. The product holds the following approval marks; CE-mark for Europe, UKCA-mark for UK, UL-EU Certificate Internationally, UAE Certificate of Compliance & AS assessment for Australia and New Zealand. For more information, please see https://protecta.co.uk/product/fire-rated-collar/

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Input
  • 5.378
  • 0.1865
  • 0.2939
  • 0.02938
Input
  • 0
  • 0
  • 0
  • 0
Input
  • 5.378
  • 0.1865
  • 0.2939
  • 0.02938
Input
  • 46.48
  • 8.012
  • 1.067
  • 2.982
Input
  • 1.078
  • 0
  • 0
  • 0
Input
  • 47.56
  • 8.012
  • 1.067
  • 2.982
Input
  • 0.003015
  • 0
  • 0
  • 0
Input
  • 0.03001
  • 0.01114
  • 0.0004263
  • 0.0009411
Input
  • 0.008081
  • 0.02707
  • 0.0004959
  • 0.002424
Input
  • 0.0484
  • 0.001353
  • 0.0004301
  • 0.0002212
Output
  • 0.0276
  • 0.000508
  • 0.00321
  • 0.0001353
Output
  • 1.105
  • 0.0985
  • 0.006311
  • 0.06789
Output
  • 0.0001446
  • 0.00005384
  • 0.000008584
  • 0.00002059
Output
  • 0
  • 0
  • 0
  • 0
Output
  • 0.001198
  • 0
  • 0.0108
  • 0
Output
  • 0.00004681
  • 0
  • 0.01415
  • 0
Output
  • 0.0003804
  • 0
  • 0.00841
  • 0
Output
  • 0.005756
  • 0
  • 0.1272
  • 0

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Abiotic depletion potential - fossil resources (ADPF)
  • 46.77
  • 8.009
  • 1.067
  • 2.982
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0001086
  • 0.000006443
  • 6.494E-7
  • 0.000003288
Acidification potential, Accumulated Exceedance (AP)
  • 0.0218
  • 0.006143
  • 0.0001831
  • 0.004502
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.04768
  • 0.0004403
  • 0.001684
  • 0.00006976
Global Warming Potential - fossil fuels (GWP-fossil)
  • 3.506
  • 0.6068
  • 0.0523
  • 0.2172
Global Warming Potential - total (GWP-total)
  • 3.556
  • 0.6079
  • 0.05405
  • 0.2174
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.002754
  • 0.0009848
  • 0.0000597
  • 0.0001119
  • 3.56
  • 0.6079
  • 0.06291
  • 0.2174
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0001937
  • 0.000007129
  • 0.000001339
  • 0.000001195
Eutrophication potential - marine (EP-marine)
  • 0.003377
  • 0.002489
  • 0.000037
  • 0.00111
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.0375
  • 0.02738
  • 0.0004028
  • 0.01234
Photochemical Ozone Creation Potential (POCP)
  • 0.01476
  • 0.007118
  • 0.0001048
  • 0.003259
Depletion potential of the stratospheric ozone layer (ODP)
  • 2.895E-7
  • 1.088E-7
  • 4.667E-9
  • 4.58E-8
Water (user) deprivation potential (WDP)
  • 171.3
  • 11.68
  • 4.617
  • 1.602

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.1498
  • 0.03625
  • 0.0172
  • 0.01292
Potential incidence of disease due to PM emissions (PM) 2
  • 2.349E-7
  • 1.758E-8
  • 7.27E-10
  • 8.901E-9
Potential Soil quality index (SQP) 2
  • 25.53
  • 6.082
  • 0.8973
  • 1.135
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 1.023E-7
  • 1.138E-9
  • 6.56E-10
  • 2.253E-9
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.689E-8
  • 0
  • 1.9E-11
  • 0
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 126.3
  • 5.999
  • 0.772
  • 1.926