Close Go back Collapse all sections
Process Data set: Isolex PEX PN10 2x15/60 mm (en) en

Key Data Set Information
Location NO
Geographical representativeness description Mainly Norway, but also the Nordic countries.
Reference year 2025
Name
Isolex PEX PN10 2x15/60 mm
Use advice for data set The analysis is a cradle-to-gate (A1 - A3) study, with option A4 transport to market. It includes the extraction and production of raw materials, transportation to the production site, the production process itself and transport to the market. A5, installation, is included for the transport of packaging waste from the construction site and the treatment of this waste - not the installation of the products.
Technical purpose of product or process Isolex Twin pipes are coiled flexible pipes with integrated frost protection. The applications are cold and/or hot tap water supply, mostly as distribution pipes between houses, cottages or other commercial facilities, especially when vulnerable landscapes, difficult terrain and cold climate can be a challenge, e.g. in periods when there is a risk of frost. The pipes have a construction consisting of two media pipes in PEX PN10, which is approved for drinking water and a protective corrugated casing pipe in HDPE, as well as self-limiting heating cable as integrated frost protection. Isolex twin pipes are suitable for permanent installations underground. More information is found on www.pipelife.no The products covered by this EPD have small variations in composition and are manufactured with the same type of equipment. The composition below represents an average for these products with components manufactured in 2021 (purchased PEX pipes) and 2022 (extruded PE pipes).
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Piping
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and waste production in-house is allocated equally among all products manufactured at Ringebu from raw materials, through mass allocation. The Ringebu factory has its own water supply. Water is not consumed, it is used for cooling and then returned to natural flows. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All raw materials and all the essential energy are included.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 1.0 kg
  • Carbon content (biogenic) - packaging: 1.0 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-01-15 - 2030-01-15
Technological representativeness
Technology description including background system For products covered by this EPD the following applies: Products used as media pipes fulfill the requirements in accordance with EN ISO 15875-2 and meeting the requirements for diffusion resistance outlined in DIN 4726. GDV and VA approved. The products do not emit substances that can impair the quality of the drinking water or cause a health hazard. The product has been tested for leaching into drinking water according with KTW-BWGL. For technical information, see our documentation for the specific finished mixed product, where PEX pipes as covered by this EPD as a constituent component. Heating cables used as integrated frost protection comply with the requirements of Directive 2014/35/EU (Low Voltage Directive) and are CE-compliant. The self-limiting heating cable has a nominal power output of 7 W/m at +5 °C, 230 V. The circuit lengths range from 1 to 100 meters, based on a 230 VAC supply and C-type characteristic circuit protection devices in accordance with EN 60898. The self-limiting heating cable has been tested and approved according to EN 62395.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 8.587
  • 0.003535
  • 0.0008583
  • 0
  • 0
  • 0.03013
  • 0.007892
  • -10.25
Input
  • 0.2539
  • 0
  • -0.6979
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 8.841
  • 0.003535
  • -0.6971
  • 0
  • 0
  • 0.03013
  • 0.007892
  • -10.25
Input
  • 41.47
  • 0.247
  • 0.02628
  • 0
  • 0
  • 0.3711
  • 0.1631
  • -1.66
Input
  • 37.38
  • 0
  • -1.194
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 78.85
  • 0.247
  • -1.168
  • 0
  • 0
  • 0.3711
  • 0.1631
  • -1.66
Input
  • 0.04074
  • 0
  • 0
  • 0
  • 0
  • 0
  • 5.704E-7
  • 0
Input
  • 0.1975
  • 0.0001265
  • 0.00001902
  • 0
  • 0
  • 0.000785
  • 0.0001675
  • -0.001796
Input
  • 0.02338
  • 0.0004522
  • 0.0001602
  • 0
  • 0
  • 0
  • 0.002677
  • -0.6078
Input
  • 0.07252
  • 0.00002641
  • 0.00001732
  • 0
  • 0
  • 0.0005112
  • 0.0001993
  • -0.01235
Output
  • 0.01334
  • 0.00001274
  • 0.0001937
  • 0
  • 0
  • 0
  • 0.02071
  • -0.00007801
Output
  • 0.4305
  • 0.01201
  • 0.07805
  • 0
  • 0
  • 0
  • 0.6654
  • -0.03922
Output
  • 0.00009416
  • 0.000001682
  • 5.804E-9
  • 0
  • 0
  • 0
  • 0.000001069
  • -0.00000869
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.04
  • 0
  • 0.01442
  • 0
  • 0
  • 0.08315
  • 0.00005747
  • 0
Output
  • 0.015
  • 0
  • 0.04997
  • 0
  • 0
  • 0.6825
  • 0.000001409
  • 0
Output
  • 0.01271
  • 0
  • 0.03469
  • 0
  • 0
  • 1.323
  • 0.00009043
  • 0
Output
  • 0.1923
  • 0
  • 0.5249
  • 0
  • 0
  • 20.02
  • 0.001368
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 77.29
  • 0.247
  • 0.02628
  • 0
  • 0
  • 0.371
  • 0.1631
  • -1.66
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0003305
  • 4.512E-7
  • 3.464E-8
  • 0
  • 0
  • 1.288E-7
  • 5.708E-8
  • -0.000001155
Acidification potential, Accumulated Exceedance (AP)
  • 0.0625
  • 0.00004694
  • 0.00001403
  • 0
  • 0
  • 0.0003495
  • 0.00005546
  • -0.0009562
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.008778
  • 0.000006761
  • 0.07623
  • 0
  • 0
  • 0.00006903
  • 0.000007255
  • -0.0002397
Global Warming Potential - fossil fuels (GWP-fossil)
  • 2.886
  • 0.01633
  • 0.003804
  • 0
  • 0
  • 2.077
  • 0.07406
  • -0.1161
Global Warming Potential - total (GWP-total)
  • 2.881
  • 0.01635
  • 0.08003
  • 0
  • 0
  • 2.077
  • 0.07407
  • -0.1203
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.003207
  • 0.000005814
  • 9.279E-7
  • 0
  • 0
  • 0.00003556
  • 0.000001692
  • -0.003999
  • 2.812
  • 0.01635
  • 0.003764
  • 0
  • 0
  • 2.077
  • 0.07414
  • -0.1186
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0004928
  • 1.305E-7
  • 2.699E-8
  • 0
  • 0
  • 0.000001165
  • 8.669E-8
  • -0.00001031
Eutrophication potential - marine (EP-marine)
  • 0.00409
  • 0.000009289
  • 0.000007247
  • 0
  • 0
  • 0.0001392
  • 0.00009504
  • -0.0003126
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.0558
  • 0.0001039
  • 0.0000606
  • 0
  • 0
  • 0.001514
  • 0.0002183
  • -0.00338
Photochemical Ozone Creation Potential (POCP)
  • 0.01785
  • 0.0000398
  • 0.0000164
  • 0
  • 0
  • 0.0003671
  • 0.00007752
  • -0.0009324
Depletion potential of the stratospheric ozone layer (ODP)
  • 1.42E-7
  • 3.7E-9
  • 3.72E-10
  • 0
  • 0
  • 2.34E-9
  • 2.193E-9
  • -0.008457
Water (user) deprivation potential (WDP)
  • 188.6
  • 0.2389
  • 0.06078
  • 0
  • 0
  • 1.133
  • 1.435
  • -20.67

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.09531
  • 0.001079
  • 0.0001033
  • 0
  • 0
  • 0.001288
  • 0.0007905
  • -0.0106
Potential incidence of disease due to PM emissions (PM) 2
  • 1.961E-7
  • 1E-9
  • 1.89E-10
  • 0
  • 0
  • 1.671E-9
  • 1.079E-9
  • -5.795E-8
Potential Soil quality index (SQP) 2
  • 13.06
  • 0.1728
  • 0.02647
  • 0
  • 0
  • 0.05266
  • 0.5989
  • -11.1
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 6.322E-7
  • 2E-10
  • 1.07E-10
  • 0
  • 0
  • 1.895E-9
  • 1.486E-8
  • -8.655E-9
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 8.134E-9
  • 0
  • 2E-12
  • 0
  • 0
  • 4.9E-11
  • 2.19E-10
  • -1.65E-10
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 539.6
  • 0.1831
  • 0.03175
  • 0
  • 0
  • 0.7327
  • 5.863
  • -9.029