Close Go back Collapse all sections
Process Data set: TECSUN (PV) H1Z2Z2-K Pure 1x10mm² BK (en) en

Key Data Set Information
Location NL
Geographical representativeness description Scandinavia
Reference year 2024
Name
TECSUN (PV) H1Z2Z2-K Pure 1x10mm² BK
Technical purpose of product or process TECSUN is a solar cable type H1Z2Z2-K for PV systems, specifically to connect solar panels to converters. This PV cable is suitable for indoor and outdoor use, as well as for underground installation and is used in building installations, residential constructions, and installations for sustainable and renewable energy. The TÜV and VDE certificates of this cable guarantee its high quality and long service life. Since the non-armoured installation cable is compatible with default socket connections, the installer can install it quickly. This cable has unique direct-bury properties, provided that the installer protects it against damage in accordance with NEN1010. It is also suitable for being installed in water, which makes it perfect for floating solar panels. This product is also available with a RED outer sheath. Conductor material Copper Core insulation material HEPR rubber Material outer sheath EVA rubber UV resistant Yes
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electrical cables and wires
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-07-12" - "2029-07-12"
Technological representativeness
Technology description including background system TECSUN (PV) H1Z2Z2-K Pure 1x10mm² BK SAP Code 20434148 External art.code 0500805 Synonyms: PV cable, Solar cable, solar panel cable, photo, voltaic, photo voltaic

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 1.149
  • 0.0004745
  • 0.07788
  • 0.00367
  • 0.0247
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2435
  • 0
  • 0
  • 0.001297
  • 0.0003453
  • 0.001756
  • -0.2859
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 1.149
  • 0.0004745
  • 0.07788
  • 0.00367
  • 0.0247
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2435
  • 0
  • 0
  • 0.001297
  • 0.0003452
  • 0.001756
  • -0.2859
Input
  • 5.336
  • 0.03768
  • 0.4873
  • 0.2916
  • 0.1253
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.5077
  • 0
  • 0
  • 0.09192
  • 0.006204
  • 0.01549
  • -0.1838
Input
  • 0.6232
  • 0
  • 0
  • 0
  • 0.0001271
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -0.6169
  • 0
  • 0
Input
  • 5.96
  • 0.03768
  • 0.4873
  • 0.2916
  • 0.1255
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.5077
  • 0
  • 0
  • 0.09192
  • -0.6107
  • 0.01549
  • -0.1838
Input
  • 0.01323
  • 0
  • 0
  • 0
  • 0.0002645
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00482
Input
  • 0.03005
  • 0.0000166
  • 0.005657
  • 0.0001284
  • 0.0007189
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0009438
  • 0
  • 0
  • 0.00004643
  • 0.000007415
  • 0.0000364
  • 0.0004185
Input
  • -0.0002362
  • 0.00005564
  • 0.001395
  • 0.0004303
  • 0.00003639
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.002982
  • 0
  • 0
  • 0.0001657
  • 0
  • 0.000009215
  • -0.01246
Input
  • 0.007034
  • 0.00000429
  • 0.0004116
  • 0.0000332
  • 0.0001513
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0005531
  • 0
  • 0
  • 0.00000968
  • 0.00005246
  • 0.00002002
  • -0.0006762
Output
  • 0.003036
  • 0.000002062
  • 0.001853
  • 0.00001596
  • 0.0001237
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0000265
  • 0
  • 0
  • 0.000004688
  • 0
  • 0.001274
  • -0.0001883
Output
  • 0.1721
  • 0.003274
  • 0.003093
  • 0.02536
  • 0.005227
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.001673
  • 0
  • 0
  • 0.004393
  • 0
  • 0.05309
  • -0.008807
Output
  • 0.00002405
  • 2.573E-7
  • 0.000002932
  • 0.000001991
  • 5.993E-7
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000007638
  • 0
  • 0
  • 6.267E-7
  • 0
  • 1.065E-7
  • -3.577E-7
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.00003252
  • 0
  • 0.001006
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.05026
  • 0.00000171
  • -0.0001886
Output
  • 0
  • 0
  • 0.007764
  • 0
  • 0.0005365
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.01906
  • 4.181E-8
  • -0.00002484
Output
  • 0
  • 0
  • 0.004592
  • 0
  • 0.0006776
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.02928
  • 0.000002713
  • -0.00006086
Output
  • 0
  • 0
  • 0.06947
  • 0
  • 0.01025
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.443
  • 0.00004104
  • -0.0009207

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 5.956
  • 0.03768
  • 0.4867
  • 0.2916
  • 0.1377
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.5066
  • 0
  • 0
  • 0.09192
  • 0.006203
  • 0.01549
  • -0.1839
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0001771
  • 4.144E-8
  • 1.499E-7
  • 3.201E-7
  • 0.000003556
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.73E-7
  • 0
  • 0
  • 1.651E-7
  • 4.935E-9
  • 5.112E-9
  • -0.00001552
Acidification potential, Accumulated Exceedance (AP)
  • 0.01755
  • 0.00001018
  • 0.0001205
  • 0.0000788
  • 0.000356
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00002815
  • 0
  • 0
  • 0.00002492
  • 0.000009888
  • 0.000005217
  • -0.002787
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.007363
  • 9.943E-7
  • 0.001026
  • 0.000007693
  • 0.000168
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00008786
  • 0
  • 0
  • 0.000002485
  • 9.802E-7
  • 1.949E-7
  • -0.00008189
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.3905
  • 0.002423
  • 0.02878
  • 0.01874
  • 0.009887
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.004323
  • 0
  • 0
  • 0.006096
  • 0.04513
  • 0.002659
  • -0.01904
Global Warming Potential - total (GWP-total)
  • 0.3983
  • 0.002424
  • 0.02985
  • 0.01876
  • 0.01006
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.004692
  • 0
  • 0
  • 0.0061
  • 0.04513
  • 0.00266
  • -0.01923
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0003838
  • 7.077E-7
  • 0.00004548
  • 0.000005473
  • 0.000008761
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0002808
  • 0
  • 0
  • 0.000002131
  • 1.829E-7
  • 2.3E-7
  • -0.0001059
  • 0.3977
  • 0.002424
  • 0.03103
  • 0.01876
  • 0.01008
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.004686
  • 0
  • 0
  • 0.0061
  • 0.04512
  • 0.002811
  • -0.01044
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0001422
  • 1.848E-8
  • 0.000002087
  • 1.429E-7
  • 0.00000289
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.923E-7
  • 0
  • 0
  • 4.787E-8
  • 8.698E-9
  • 1.07E-8
  • -0.00001887
Eutrophication potential - marine (EP-marine)
  • 0.001197
  • 0.000003062
  • 0.00001821
  • 0.00002369
  • 0.00002517
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000004794
  • 0
  • 0
  • 0.00000739
  • 0.000004729
  • 0.000004133
  • -0.0001205
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.01767
  • 0.00003386
  • 0.0002029
  • 0.000262
  • 0.0003664
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00006311
  • 0
  • 0
  • 0.00008173
  • 0.00004847
  • 0.00002097
  • -0.001837
Photochemical Ozone Creation Potential (POCP)
  • 0.00437
  • 0.00001089
  • 0.00005298
  • 0.00008425
  • 0.00009123
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00001438
  • 0
  • 0
  • 0.00002502
  • 0.00001169
  • 0.000006406
  • -0.0004991
Depletion potential of the stratospheric ozone layer (ODP)
  • 1.863E-7
  • 5.6E-10
  • 2.438E-9
  • 4.331E-9
  • 3.906E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.12E-9
  • 0
  • 0
  • 1.39E-9
  • 9.9E-11
  • 1.95E-10
  • -0.0001871
Water (user) deprivation potential (WDP)
  • 25.83
  • 0.02893
  • 6.035
  • 0.2237
  • 0.6515
  • 0
  • 0
  • 0
  • 0
  • 0
  • 51.41
  • 0
  • 0
  • 0.08768
  • 0.04476
  • 0.3247
  • 0.4445

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.02485
  • 0.0001647
  • 0.00355
  • 0.001274
  • 0.000607
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.01737
  • 0
  • 0
  • 0.0004018
  • 0.0000156
  • 0.00009563
  • -0.0004174
Potential incidence of disease due to PM emissions (PM) 2
  • 4.975E-8
  • 2.13E-10
  • 3.47E-10
  • 1.65E-9
  • 1.051E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.03E-10
  • 0
  • 0
  • 4.39E-10
  • 4.4E-11
  • 9.4E-11
  • -6.813E-9
Potential Soil quality index (SQP) 2
  • 4.282
  • 0.04318
  • 0.1021
  • 0.3345
  • 0.09724
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2243
  • 0
  • 0
  • 0.06337
  • 0.001132
  • 0.03586
  • -0.5685
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 3.009E-7
  • 2.7E-11
  • 3.17E-10
  • 2.06E-10
  • 6.033E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.85E-10
  • 0
  • 0
  • 7.3E-11
  • 1.19E-10
  • 2E-11
  • -3.097E-8
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 4.023E-9
  • 0
  • 9E-12
  • 0
  • 8.1E-11
  • 0
  • 0
  • 0
  • 0
  • 0
  • 8E-12
  • 0
  • 0
  • 0
  • 3E-12
  • 1E-12
  • -3.62E-10
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 217.5
  • 0.02756
  • 0.3082
  • 0.2132
  • 4.78
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2673
  • 0
  • 0
  • 0.0677
  • 0.09535
  • 20.75
  • -25.64