Key Data Set Information | |
Location | NO |
Geographical representativeness description | Nordic |
Reference year | 2025 |
Name |
|
Use advice for data set | Cradle to Gate. The following stages have been declared: A1-A4 |
Technical purpose of product or process | Prefix pre-wired corrugated, Halogen free pliable / self-recovering conduit acc. to EN 61386-1 and EN 61386-22. Halogenfree KNX/EIB cable for transmission of BUS signals in intelegent building management systems based on standards of the Europeing Informatiin BUS EIB. Signals received from system sensors (Lighting, temperature, air conditioning, access control and others) are gathered in the EIB bus, and subsequently processed and used to control a device's operation. . The screen mimimizes EMC effects as susceptibility to noise and reduction of frequency emission. KNX: Worldvide standard for home and building control. EIB: Europaing Installation Bus. Halogen-free pipe and cables offer enhanced protection against smoke and toxid gases developed during fire. Products fulfils requirements of norms concerning quantity of toxic chemical compounds giving off during combustion. EN50575 CPR Class Dca CONDUIT Construction standards EN 611386-1; EN 61386-22 ICTA 34423 CABLE Construction - Factory standard |
Classification |
Class name
:
Hierarchy level
|
General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Data from material supplier and the LCA generator has been accepted "As-Is" Data from processing TECCON in-house has been repeated ongoingly without major deviations. Figures given in document are worst case values. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. The allocation is made in accordance with the guidelines given in EN 15804. Raw material - Information derived from manufactory and from a LCA generator Processing: Derived from actual measurements during production of the individual units/stages. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. All major materials have been included. Substance representing <1% have not been included. This include folio film for packaging! |
Copyright | Yes |
Owner of data set | |
Quantitative reference | |
Reference flow(s) |
|
Biogenic carbon content |
|
Time representativeness | |
Data set valid until | 2030 |
Time representativeness description | 2025-04-29 - 2030-04-29 |
Technological representativeness | |
Technology description including background system | Corrugated Conduit Pliable/Self recovering halogen free Polypropylene Compression force 750N Marking EN, Date, and meter marking: 0-100m Temperature - operation -25 to + 90°C Temperature - installation -5 to + 90°C Bending Radius 8 x D Resistant to fire performance Flame retardant, self-extinguishing, low smoke toxic emission Insulations resistance >100M? at 500V in 1 min Test - mechanical Acc. EN 61386-1; EN 61386-22 Test - electrical Acc. EN 61386-1; >2,0kV 50HZ in 15 min CABLE Construction standards Factory Standard Conductor Single annealed cooper wire with diameter 0,8 mm. EN60228 Insulation - conductor Coloured special PE, nominal thickness 0,40 mm. Conductor marking 1. Red-Black 2. White-Yellow Conductor laying Cores twisted in Quad Screen Aluminium backed polyester tape with tinned copper drain wire Ø 0,4mm placed longitudinally under the screen Jacket Green halogen free, fire retardant og self extinguishing Marking «KNX/E-BUS» LSZH Bitner EB0005 E-Bus 2x2x0,8mm Ce RoHs Voltage - norminel Uo/U 800V Voltage - test - 1min/5min 4000/2500 Max capacitance par 100nF/km (conductor-conductor) Max conductor resistance v/ 20°C : 73,2 Ohm/km Resistance insulation 100MOhm.km Resistant to fire performance EN60332-1 CPR EN 50575 compliance Dca s1, d0, a1 DoP 17_0025_00 Temperature - operation -30 to 80 °C Temperature - installation -50 to 50 °C |
Subtype | specific dataset | ||||
LCA methodology report | |||||
Data sources, treatment and representativeness | |||||
Documentation of data quality management | |||||
Data source(s) used for this data set | |||||
Completeness | |||||
Validation | |||||
| |||||
Compliance Declarations |
Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
Data generator | |
Data set generator / modeller |
|
Data entry by | |
Time stamp (last saved) | 2025-06-28T20:08:49 |
Data set format(s) | |
Publication and ownership | |
UUID | 8c503de4-3037-4976-8fa6-1294c3b71896 |
Date of last revision | 2025-04-28T14:40:32.8467Z |
Data set version | 00.03.000 |
Registration authority | |
Registration number | NEPD-9890-9835 |
Owner of data set | |
Copyright | Yes |
License type | Free of charge for all users and uses |
Access and use restrictions | None |
Indicators of life cycle