| Key Data Set Information | |
| Location | CH |
| Geographical representativeness description | Europe |
| Reference year | 2024 |
| Name |
|
| Use advice for data set | The life cycle assessment is a “cradle-to-grave” analysis, and the system boundaries are defined according to EN 50693, as required by the EPDItaly007. For transparency reasons, the manufacturing stage is further divided into an upstream and core stage. |
| Technical purpose of product or process | This Environmental Product Declaration is a “specific product EPD”, and the declared product is the single phase FSKII+, including related accessories and packaging. The single phase FSKII+ with nominal current 1250A compose the reference flow, including the related accessories and packaging. The single phase FSKII+ with 2500A nominal current will be analyzed through extrapolation rules derived from the reference device. General technical information of the single phase FSKII+ are presented below. Description Single phase FSKII+ Ratings Rated voltage [kV] 25 Rated current [A] 1250 Rated short circuit breaking current [kA] 25 The single phase FSKII+ are manufactured by ABB manufacturing site located in Dalmine, Italy. The manufacturing site is certified according to the following standards: - ISO 9001:2015 – Quality Management Systems - ISO 14001:2015 – Environmental Management Systems - ISO 45001:2018 – Occupational Health and Safety Management Systems -ISO 50001:2018 – Energy management systems The constituent materials of the single phase FSKII+ with 1250A of nominal current are presented below. Type Material Weight [kg] Weight % Metals Steel 39.17 25.06% Stainless steel 43.03 27.53% Copper 13.58 8.69% Aluminum 25.58 16.36% Other metals 1.21 0.77% Plastics Silicone 28.72 18.38% Other plastics 1.72 1.10% Others Ceramics 2.40 1.53% Cables 0.41 0.26% Electronics 0.49 0.32% Zirconium 0.00 0.00% Total 156.32 100% |
| General comment on data set | Both primary and secondary data are used. The main sources for primary data are the bill of materials (BOM), technical drawings, and site-specific foreground data provided by ABB,. For all processes for which primary data are not available, generic background data originating from the ecoinvent v3.9.1 database, with system model “allocation, cut-off by classification”, are used. The LCA software used for the calculations is SimaPro 9.5. The utility consumption and waste generation by ABB, in the core manufacturing stage, is allocated to the production of one reference product according to applicable rules. For the end-of-life allocation, the “Polluter Pays” principle is adopted according to what is defined in the CEN/TR 16970 standard. However, the potential benefits and avoided loads from recovery and recycling processes are not considered because it is not required by the PCR EPDItaly007 “Electronic and electrical products and systems”. According to PCR EPDItaly007 “Electronic and electrical products and systems”, the cutoff criteria can be set to a maximum of 2% of the overall environmental impacts. In this LCA, components like stickers, glue and grease have been excluded as their weights are negligible. The same applies to packaging, where small parts such as sticking labels are even smaller fraction of the total mass. Burnishing, oiling, black oxide, and phosphate surface treatments have also been excluded due to the low amount of surface involved. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2029 |
| Time representativeness description | 2024-12-19 - 2029-12-19 |
| Technological representativeness | |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2025-09-01T01:36:36 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 8b0dba62-ac07-4462-86da-fddd692dde09 |
| Date of last revision | 2025-07-13T16:58:07.212774Z |
| Data set version | 00.05.000 |
| Registration authority | |
| Registration number | NEPD-8550-8200 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle