Process Data set: HF-Coilfix PP16/ RG 6 Triple 1/4,6 LSZH (en) en

Key Data Set Information
Location NO
Geographical representativeness description Nordic
Reference year 2025
Name
HF-Coilfix PP16/ RG 6 Triple 1/4,6 LSZH
Use advice for data set Cradle to Gate. The following stages have been declared: A1-A4
Technical purpose of product or process Pre-wired corrugated, pliable self-recovering conduit acc. to EN 61386-1 and EN 61386-22. Coax cable - RG6 type is specifically designed for use in multimedia networks and complies with screening of class A+ level. A construction with low, high screening efficiency - tripple and high resistance to aging. The cable can be used indoor, fixed installed in dry and moisty enviorements, and outdoor if protected against UV. May not be burield. The cable are Halogen Free, Non Corrosive and Flame retardant, meet EN 50575 clasification Dca. CONDUIT Construction standards EN 611386-1; EN 61386-22 ICTA 34423 CABLE Construction standards EN 50117-1; EN 50117-2-4
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Data from material supplier and the LCA generator has been accepted "As-Is" Data from processing TECCON in-house has been repeated ongoingly without major deviations. Figures given in document are worst case values. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. The allocation is made in accordance with the guidelines given in EN 15804. Raw material - Information derived from manufactory and from a LCA generator Processing: Derived from actual measurements during production of the individual units/stages. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. All major materials have been included. Substance representing <1% have not been included. This include folio film for packaging!
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-04-10 - 2030-04-10
Technological representativeness
Technology description including background system Corrugated Conduit Pliable/Self recovering halogen free Polypropylene Compression force 750N Marking EN, Date, and meter marking: 0-100m Temperature - operation -25 to + 90°C Temperature - installation -5 to + 90°C Bending Radius 8 x D Resistant to fire performance Flame retardant, self-extinguishing, low smoke toxic emission Insulations resistance >100M? at 500V in 1 min Test - mechanical Acc. EN 61386-1; EN 61386-22 Test - electrical Acc. EN 61386-1; >2,0kV 50HZ in 15 min CABLE Conductor 1,02 mm bare copper Insulation - dielectric 4,6 mm Gas injected Skin/Foam/Skin PE Shield 1 Aluminium Foil bonded to insulation Shield 2 Aluminium Wire Braiding - 60% coverage Shield 3 Aluminium Foil bonded to outer sheath Jacket 6,80 mm HFFR White Marking HQ 103 A+ HFFR Dca + meter mark Impedance 75± 3? Capacitance 53± 2pF/m Velocity of Propagation 84% Insulation Resistance > G?xkm Operation Voltage 1300V Test Voltage 3000V Inner Conductor DCR 22,10 ?/km Cable Weight 43,1kg/km Bending radius min. 35mm Tensile Strength max. 110N Temperature - installed -30 to +70 CPR EN 50575 compliance Dca DOP Attenuation at 20° 5 MHz 1,7 dB/100m 50 MHz 4,7 dB/100m 230 MHz 9,1 dB/100m 470 MHz 14 dB/100m 862 MHz 19,1 dB/100m 1000 MHz 20,8 dB/100m 1750 MHz 28,7 dB/100m 2150 MHz 32,2 dB/100m 2400 MHz 33,9 dB/100m 3000MHz 38,2 dB/100m Return Loss 5-470 MHz >30 dB 470-122 MHz >25 dB 1200-2000 MHz >23 dB 2000-3000 MHz >18 dB Transfer Impedance 5-30 MHz >2,5m?/m Screening Attenuation 30-1200 MHz >110 dB 1200-200MHz >95 dB 2000-3000MHz >85 dB

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 0.2085
  • 0.001592
  • 0.02062
  • 0.002903
  • 0.7034
  • 0
  • 0
  • 0.0005798
  • 0.0007074
  • -2.809
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.2085
  • 0.001592
  • 0.02062
  • 0.002903
  • 0.7034
  • 0
  • 0
  • 0.0005797
  • 0.0007074
  • -2.809
Input
  • 3.729
  • 0.124
  • 0.05431
  • 0.2028
  • 48.89
  • 0
  • 0
  • 0.01935
  • 0.01177
  • -0.9925
Input
  • 2.795
  • 0
  • 0
  • 0
  • -0.04975
  • 0
  • 0
  • -2.687
  • 0
  • -0.3023
Input
  • 6.524
  • 0.124
  • 0.05431
  • 0.2028
  • 48.84
  • 0
  • 0
  • -2.668
  • 0.01177
  • -1.295
Input
  • 0.001807
  • 0
  • 0
  • 0
  • 0.00004109
  • 0
  • 0
  • 0
  • 0.000003894
  • 0.005845
Input
  • 0.006802
  • 0.00005506
  • 0.0001328
  • 0.0001038
  • 0.02514
  • 0
  • 0
  • 0.00001611
  • 0.00001542
  • -0.0005388
Input
  • 0.00209
  • 0.0002389
  • 0.0001008
  • 0.0003713
  • 0.08943
  • 0
  • 0
  • 0
  • 0.0007051
  • -0.1512
Input
  • 0.003084
  • 0.00001194
  • 0.0001169
  • 0.00002169
  • 0.005287
  • 0
  • 0
  • 0.00005393
  • 0.00001375
  • -0.004991
Output
  • 0.0008656
  • 0.000006184
  • 0.00002202
  • 0.00001046
  • 0.002635
  • 0
  • 0
  • 0
  • 0.005404
  • -0.0002647
Output
  • 0.02477
  • 0.004899
  • 0.0006231
  • 0.009861
  • 2.377
  • 0
  • 0
  • 0
  • 0.03918
  • -0.02096
Output
  • 0.000004931
  • 8.481E-7
  • 3.89E-7
  • 0.000001381
  • 0.0003326
  • 0
  • 0
  • 0
  • 7.637E-8
  • -0.000002767
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.003418
  • 0
  • 0.001777
  • 0
  • 0
  • 0.0211
  • 0.000002905
  • -0.0002339
Output
  • 0
  • 0
  • 7.43E-9
  • 0
  • 0.002128
  • 0
  • 0
  • 0.1063
  • 1.694E-7
  • -0.00005235
Output
  • 0
  • 0
  • 0.001034
  • 0
  • 0.003737
  • 0
  • 0
  • 0.1856
  • 0.000005472
  • -0.0001126
Output
  • 0
  • 0
  • 0.01564
  • 0
  • 0.05654
  • 0
  • 0
  • 2.809
  • 0.00008278
  • -0.001704

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 6.288
  • 0.124
  • 0.05388
  • 0.2028
  • 48.94
  • 0
  • 0
  • 0.01935
  • 0.01177
  • -1.269
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.00002001
  • 1.964E-7
  • 1.714E-8
  • 3.704E-7
  • 0.00008958
  • 0
  • 0
  • 1.042E-8
  • 4.731E-9
  • -0.0000193
Acidification potential, Accumulated Exceedance (AP)
  • 0.007165
  • 0.00008013
  • 0.00003545
  • 0.00003854
  • 0.009428
  • 0
  • 0
  • 0.00003643
  • 0.000004129
  • -0.003664
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.002431
  • 0.000003258
  • 0.000007373
  • 0.000005551
  • 0.001386
  • 0
  • 0
  • 0.000002372
  • 5.107E-7
  • -0.0002611
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.2201
  • 0.008499
  • 0.005427
  • 0.01341
  • 3.239
  • 0
  • 0
  • 0.2898
  • 0.00409
  • -0.06823
Global Warming Potential - total (GWP-total)
  • 0.2226
  • 0.008504
  • 0.005438
  • 0.01342
  • 3.241
  • 0
  • 0
  • 0.2898
  • 0.00409
  • -0.06952
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0001112
  • 0.000003695
  • 0.000003471
  • 0.000004773
  • 0.001151
  • 0
  • 0
  • 3.567E-7
  • 1.458E-7
  • -0.001029
  • 0.2134
  • 0.008504
  • 0.004207
  • 0.01342
  • 3.24
  • 0
  • 0
  • 0.2898
  • 0.004115
  • -0.05728
Eutrophication potential - freshwater (EP-freshwater)
  • 0.00006772
  • 6.061E-8
  • 4.707E-8
  • 1.071E-7
  • 0.00002719
  • 0
  • 0
  • 2.344E-8
  • 9.018E-9
  • -0.00002551
Eutrophication potential - marine (EP-marine)
  • 0.000312
  • 0.00001864
  • 0.000005114
  • 0.000007626
  • 0.001843
  • 0
  • 0
  • 0.00001745
  • 0.000005259
  • -0.0002273
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.004176
  • 0.0002077
  • 0.0000569
  • 0.0000853
  • 0.02063
  • 0
  • 0
  • 0.0001888
  • 0.00001593
  • -0.003109
Photochemical Ozone Creation Potential (POCP)
  • 0.001537
  • 0.00005912
  • 0.00001735
  • 0.00003268
  • 0.007899
  • 0
  • 0
  • 0.00004532
  • 0.00000528
  • -0.0008723
Depletion potential of the stratospheric ozone layer (ODP)
  • 6.647E-9
  • 1.916E-9
  • 7.21E-10
  • 3.038E-9
  • 7.313E-7
  • 0
  • 0
  • 2.25E-10
  • 1.52E-10
  • -0.002115
Water (user) deprivation potential (WDP)
  • 6.617
  • 0.1012
  • 0.6588
  • 0.1961
  • 47.36
  • 0
  • 0
  • 0.04451
  • 0.1289
  • -6.822

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.005563
  • 0.0005399
  • 0.0003886
  • 0.0008863
  • 0.2134
  • 0
  • 0
  • 0.00003329
  • 0.0000591
  • -0.003429
Potential incidence of disease due to PM emissions (PM) 2
  • 1.635E-8
  • 4.03E-10
  • 2.85E-10
  • 8.21E-10
  • 1.98E-7
  • 0
  • 0
  • 1.59E-10
  • 7.1E-11
  • -2.18E-8
Potential Soil quality index (SQP) 2
  • 0.8244
  • 0.07291
  • 0.03036
  • 0.1418
  • 34.16
  • 0
  • 0
  • 0.002403
  • 0.03877
  • -3.191
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 1.079E-7
  • 8.1E-11
  • 3.3E-11
  • 1.64E-10
  • 4.176E-8
  • 0
  • 0
  • 2.45E-10
  • 1.8E-11
  • -3.965E-8
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.235E-9
  • 0
  • 5E-12
  • 0
  • 2.6E-11
  • 0
  • 0
  • 7E-12
  • 0
  • -4.82E-10
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 50.89
  • 0.08808
  • 0.05012
  • 0.1503
  • 37.28
  • 0
  • 0
  • 0.05746
  • 2.429
  • -33.25