| Key Data Set Information | |
| Location | DE |
| Geographical representativeness description | Europe |
| Reference year | 2025 |
| Name |
|
| Use advice for data set | The analysis is a cradle-to-grave study made for one charger manufactured , installed and used under ordinary conditions over its lifetime. Modules A1-A5 are included in the analysis. It includes the extraction and production of raw materials, transportation to the factory, the production process itself, transportation to market and installation of the product. B6 is the operational energy usage based on a normal use. C1-C4, D are mandatory modules which include end of life treatment of materials and the benefits from recycling. |
| Technical purpose of product or process | Zaptec Go EU is an alternating current (AC) wall charging station in accordance with IEC 61851-1, EVSE Mode 3. Software interfaces available Zaptec App Third-party integration alternatives (API, Webhooks). OCPP 1.6J |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2030 |
| Time representativeness description | 2025-10-31 - 2030-10-31 |
| Technological representativeness | |
| Technology description including background system | Dimensions (mm): H:242 X W:180 X D:75 Installation Cicuit: Max 40A circuit breaker on installation circuit for charging stations Installation network, Voltages TN, IT and TT 230VAC ± 10% 400VAC ± 10% Max. current and charging output 22kW at 32A/3-phase (TN networks) 12,7 kW at 32A/3-phase (IT networks) 7.4kW at 32A/1 phase (TN networks) Temperature range –30°C to +40°C Degree of protection IP54, indoor and outdoor use IK8 impact protection UL94 5VB flammability rating UV resistant Electrical protection Protection class I (4kV AC and 6kV impulse, insulation) Overvoltage category III (4kV) Charging socket IEC 62196-2 Type 2 Female Electronic lock, can be permanently locked by user. Integrated residual current protection RDC-DD (6mA DC) according to IEC 62955 Electronic, automatic reset by replugging Type 2 cable. Energy metering Integrated 3-phase energy meter ~3% accuracy on readings Communications interface and cloud connection/network 4G LTE-M WiFi 2.4 GHz, IEEE 802.11 b/g/n (channels 1-11) HMI, Identification and configuration Bluetooth Low Energy (BLE 4.2) RFID: ISO/IEC 14443 Type A (Mifare Classic, 13.56 MHz) RGBW LED circle for device status 2W power usage at standby |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2026-02-18T12:36:45 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 818ba1e1-cbea-4234-aed7-ead09442bb5a |
| Date of last revision | 2025-10-28T12:50:24.7496035Z |
| Data set version | 00.02.001 |
| Registration authority | |
| Registration number | NEPD-12905-14133 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle