| Key Data Set Information | |
| Location | ES |
| Geographical representativeness description | Nordic |
| Reference year | 2025 |
| Name |
|
| Use advice for data set | Cradle to Gate. The following stages have been declared: A1-A4 |
| Technical purpose of product or process | Tec Flex RV-K 0,6/1 kV power cables are specially indicated for its use in distribution networks, power stations, industries or buildings, and electrical installations in steel ships. For electrical energy transport and distribution, distribution networks, protected or not. For indoor and outdoor installations. Non-suitable for facilities of feeding of submerged pumps Surface mounted (directly installed or on cable trays, cable ladders, cleats, brackets or in cable ducting (conduit, pipes or similar closed systems)). Embedded (directly or in cable ducting). In building voids and cavities (directly or on cable trays, cable ladders, in cable ducting). Buried in ground (directly or in conduit) General: UNE 21-123-91; IEC 60502-21-123-91/1; HD 603-1 Flexible installation cable 0,6/1,0kV |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. They represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on registered EPDs according to EN 15804, Ostfold Research databases, ecoinvent and other LCA databases. The data quality of the raw materials in A1 is presented in the table below. Data from material supplier and the LCA generator has been accepted "As-Is" Data from processing TECCON in-house has been repeated ongoingly without major deviations. Figures given in document are worst case values. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. The allocation is made in accordance with the guidelines given in EN 15804. Raw material - Information derived from manufactory and from a LCA generator Processing: Derived from actual measurements during production of the individual units/stages Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. All major materials have been included. Substance representing <1% have not been included. This include folio film for packaging! |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2030 |
| Time representativeness description | 2025-04-30 - 2030-04-30 |
| Technological representativeness | |
| Technology description including background system | Cable Standard IEC 60502-1 Conductor Annealed electrolytic flexible multi-stranded copper conductor, class 5, IEC 60228 Insulation XLPE – according to standard IEC 60502-1 Coloured According to HD 308 S2 Colour code Cenelec. Yellow/Green; Blue, brown, Black, Grey Bedding PVC Jacket PVC, White or Grey. UV stabilized. (PVC type ST2 according to IEC 60502-1) Marking RV-K 0,6/1,0kV xx G mm² Year/lot Rated Voltage U0/U 0,6/1,0kV Volatge test 3500V Service temp 90° C Short circuit temp 250° C Fire performance EN 50575:2014+A1:2016 Flame retardant EN 60332-1-2 CPR EN50575 Eca Temperature – service -25- 60° Temperature – installation 0 - 50° Bending radius 10 x D Marking – Approvals – directives RohS Low Voltage Directive CPR compliant Marine approval Registered for use in Swan Buildings |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2025-08-02T12:22:56 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 7b3f0092-2dbb-426f-a62f-dd39feb4fcec |
| Date of last revision | 2025-04-29T10:36:09.9217714Z |
| Data set version | 00.03.000 |
| Registration authority | |
| Registration number | NEPD-9881-9868 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle