| Key Data Set Information | |
| Location | DK |
| Geographical representativeness description | Denmark, Sweden, Norway, Finland & UK |
| Reference year | 2024 |
| Name |
|
| Use advice for data set | Module A1: Packaging has not been included due to several different available packaging options*. Module A4: The transportation distances provided in this EPD are derived from precise data concerning the distances between the production facility and various sales departments in different countries. Subsequently, it is assumed that the distribution from each of these sales departments to the end customers covers an approximate distance of 300 km*. Module C2: The estimated transportation distance to the waste handling facility in this EPD is 100 km, assuming the use of a truck as the transportation method. *For specific packaging and transport scenarios please take contact for a project specific EPD. |
| Technical purpose of product or process | The Roth Pex-5 High Performance floor heating pipe meets all requirements for a floor heating pipe. The pipe is flexible and easy to work with, even in cold weather. The Roth Pex-5 High Performance pipe is a 5-layer pipe, which means that the oxygen barrier is located inside the pipe, ensuring it does not contribute to creaking noises when the pipes are used in metallic heat distribution plates. To ensure consistent quality and adherence to standards, production of the Roth Pex-5 High Performance takes place at Roth's own German factories. The manufacturing process is rigorously quality assured in accordance with ISO 9001, guaranteeing the highest level of product excellence and reliability. The Roth Pex-5 High Performance pipe is available in the dimension 16 x 2.0, ensuring compatbility with all Roth plate systems and associated fittings. |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2029 |
| Time representativeness description | "2024-04-22" - "2029-04-22" |
| Technological representativeness | |
| Technology description including background system | The Roth Pex-5 High Performance pipe can withstand a continuous operating temperature of 70°C (briefly up to 95°C) at a pressure of 10 bar according to EN 15875. |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2024-12-31T12:48:42 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 7b2c87e5-1aea-4879-8b8c-7f2a5aceba96 |
| Date of last revision | 2024-04-16T06:32:34.4581313Z |
| Data set version | 00.04.000 |
| Registration authority | |
| Registration number | NEPD-6451-5713 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle