Close Go back Collapse all sections
Process Data set: EK-JS (en) en

Key Data Set Information
Location DE
Geographical representativeness description Europe
Reference year 2024
Name
EK-JS
Technical purpose of product or process Rectangular sheet steel smoke control damper including ventilation function for the removal of smoke and heat in smoke extract systems, as well as for the controlled flow of the necessary supply air. Suitable as a support for keeping safety rooms and their anterooms smoke-free in pressurised ventilation systems (DBA), e.g., in fire brigade lift shafts or for smoke removal in escape tunnels. For more information see: www.trox.de/en/d9763c7a5fa5badc. Type EK-JS smoke control dampers are tested according to EN12101-8 and EN 1366-10. In rectangular steel and stainless steel construction. Intended for the discharge of smoke and heat in smoke extract systems and for the flow of necessary supply air into the area from which smoke is to be extracted. EK-JS is intended for use in pressurised ventilation systems (DBA) in order to keep safety stairwells and their anterooms and fire brigade lift shafts or escape tunnels smoke-free. They thus enable the controlled discharge of released smoke. EK-JS is intended for use in single sections and may be used at elevated operating temperatures of up to 600 °C on and in horizontally and vertically aligned smoke extract ducts according to EN 12101-7, tested according to EN 1366-9. EK-JS can be used in combined systems (combination damper) for ventilation and is suitable for restricting extract air volume flows. The OPEN-CLOSE actuators can be signalled either with ready-wired actuator control modules or with bus modules.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Ventilation components
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Energy, water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
  • - 1.0 * 1.0 Stück (Number of pieces)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-01-02" - "2029-01-02"
Technological representativeness
Technology description including background system Nominal sizes B × H: 100 × 100 – 1250 × 2560 mm. Casing length: 200 mm. Volume flow rate range at 10 m/s: From 360 m³/h to 115110 m³/h or from 100 l/s to 31975 l/s. Differential pressure range: Pressure level 3: -1500 to 500 Pa. Operating temperature: 30 °C – 50 °C without temperatures below the dew point. Upstream velocity with same upstream and downstream flow: = 12 m/s. = 20 m/s For dimensions, see motor allocation matrix (technical clarification with TROX required for some sizes). Closed damper blade air leakage: EN 1751, at least class 2, from nominal width 840 × 480 class 3. Casing leakage: EN 1751, class B, from nominal width 840 × 480 class C. EC conformity: EU Construction Products Regulation No. 305/2011. EN 12101-8: Smoke and heat control systems – Part 8: Smoke control dampers. EN 1366-10: Fire resistance tests for service installations – Part 10: Smoke control dampers. EN 13501-4: Fire classification of construction products and building elements – Part 4: Fire resistance tests on components of smoke control. EN 1751: Ventilation for buildings – Air terminal devices. Declaration of performance: DoP/EK-JS/001. For more technical data see: www.trox.de/en/d9763c7a5fa5badc.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 186
  • 0.1948
  • 0.0005073
  • 0.01217
  • 0.0184
  • 0.008024
  • -4.524
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 209.5
  • 0.1948
  • 0.0005073
  • 0.01217
  • 0.0184
  • 0.008024
  • -4.524
Input
  • 1838
  • 13.61
  • 0.0938
  • 0.8504
  • 0.07994
  • 0.1003
  • -23.42
Input
  • 0.8058
  • 0
  • 0
  • 0
  • -0.135
  • 0
  • 0
Input
  • 1.84E+3
  • 13.61
  • 0.0938
  • 0.8504
  • -0.05506
  • 0.1003
  • -23.42
Input
  • 4.125
  • 0
  • 0.00004606
  • 0
  • 0.000009479
  • 0.0001636
  • 0.04124
Input
  • 38.64
  • 0.006968
  • 0.00001248
  • 0.0004355
  • 0.0003972
  • 0.00005207
  • 0.06394
Input
  • 9.213
  • 0.02491
  • 0.0001837
  • 0.001557
  • 0.00001008
  • 0.001541
  • 1.794
Input
  • 0.677
  • 0.001455
  • 0.000004827
  • 0.00009094
  • 0.00008389
  • 0.0001095
  • -0.02264
Output
  • 0.7079
  • 0.0007017
  • 0.000002761
  • 0.00004385
  • 0.000001099
  • 0.007501
  • -0.007783
Output
  • 41.85
  • 0.6617
  • 0.0001111
  • 0.04135
  • 0.007536
  • 0.5468
  • -0.9411
Output
  • 0.004548
  • 0.00009268
  • 6.513E-7
  • 0.000005792
  • 1.114E-7
  • 4.185E-8
  • -0.00002905
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 31.22
  • 0
  • 0.00004523
  • 0
  • 4.608
  • 0.000001508
  • -0.001614
Output
  • 5.801
  • 0
  • 1.402E-7
  • 0
  • 0.007501
  • 3.055E-8
  • -0.0002125
Output
  • 3.939
  • 0
  • 4.808E-7
  • 0
  • 0.00000945
  • 1.256E-7
  • -0.0005206
Output
  • 59.59
  • 0
  • 0.000007274
  • 0
  • 0.000143
  • 0.0000019
  • -0.007877

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 1839
  • 13.6
  • 0.0938
  • 0.8503
  • 0.07993
  • 0.1002
  • -23.42
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.01817
  • 0.00002486
  • 1.046E-8
  • 0.000001553
  • 6.268E-8
  • 3.289E-8
  • -0.0001608
Acidification potential, Accumulated Exceedance (AP)
  • 0.4868
  • 0.002586
  • 0.00007129
  • 0.0001616
  • 0.00002654
  • 0.00003301
  • -0.0363
Global Warming Potential - biogenic (GWP-biogenic)
  • 1.394
  • 0.0003724
  • 0.000001278
  • 0.00002328
  • 0.00004486
  • 0.000004047
  • -0.004447
Global Warming Potential - fossil fuels (GWP-fossil)
  • 127.7
  • 0.8998
  • 0.006815
  • 0.05624
  • 0.01691
  • 0.004749
  • -2.456
Global Warming Potential - total (GWP-total)
  • 129.2
  • 0.9005
  • 0.006817
  • 0.05628
  • 0.01696
  • 0.004768
  • -2.474
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.1022
  • 0.0003203
  • 5.371E-7
  • 0.00002002
  • 0.000004693
  • 0.00001473
  • -0.01272
  • 132.8
  • 0.9005
  • 0.006817
  • 0.05628
  • 0.01696
  • 0.004768
  • -3.212
Eutrophication potential - freshwater (EP-freshwater)
  • 0.009351
  • 0.000007189
  • 2.481E-8
  • 4.493E-7
  • 4.219E-7
  • 9.886E-8
  • -0.0002878
Eutrophication potential - marine (EP-marine)
  • 0.07095
  • 0.0005117
  • 0.00003147
  • 0.00003198
  • 0.000005534
  • 0.00001082
  • -0.003246
Eutrophication potential - terrestrial (EP-terrestrial)
  • 1.312
  • 0.005723
  • 0.0003453
  • 0.0003577
  • 0.00006267
  • 0.000119
  • -0.03873
Photochemical Ozone Creation Potential (POCP)
  • 0.24
  • 0.002192
  • 0.00009493
  • 0.000137
  • 0.00001747
  • 0.00003741
  • -0.01455
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.00001181
  • 2.038E-7
  • 1.473E-9
  • 1.274E-8
  • 1.959E-9
  • 1.303E-9
  • -1.712E-7
Water (user) deprivation potential (WDP)
  • 8.68E+3
  • 13.16
  • 0.01993
  • 0.8225
  • 1.503
  • 0.3016
  • -260.7

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 4.002
  • 0.05947
  • 0.0004019
  • 0.003717
  • 0.0005019
  • 0.0003914
  • -0.02987
Potential incidence of disease due to PM emissions (PM) 2
  • 0.000003528
  • 5.509E-8
  • 1.886E-9
  • 3.443E-9
  • 3.99E-10
  • 6.51E-10
  • -2.314E-7
Potential Soil quality index (SQP) 2
  • 611.9
  • 9.516
  • 0.0119
  • 0.5948
  • 0.03685
  • 0.339
  • -3.896
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000002887
  • 1.102E-8
  • 4.7E-11
  • 6.89E-10
  • 1.05E-10
  • 2.334E-8
  • -1.045E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.927E-7
  • 0
  • 0
  • 0
  • 1.6E-11
  • 3.46E-10
  • -1.28E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 2026
  • 10.09
  • 0.05126
  • 0.6303
  • 0.3461
  • 3.564
  • -321.5