Close Go back Collapse all sections
Process Data set: Herning Wall Midi (en) en

Key Data Set Information
Location CN
Geographical representativeness description Nordic + Northwestern Europe
Reference year 2024
Name
Herning Wall Midi
Technical purpose of product or process A stylishly designed classic outdoor luminaire that is equally at home in urban and more rural settings. In solid powder-coated aluminium and with a tempered glass front, it is equally suitable in domestic or public settings. The glass front conceals access to switches for 3000K/4000K and for 2 lumen levels, i.e. 4 combinations in one product. By default, it is set to 3000K and the highest lumen level. Easy installation with wall bracket and quick connector. Multiple rear surface cable inputs plus punch-out entry points. System Wattage: null W. Luminous flux: 1060/1140/1770/1920lm. Efficacy: 82/88/71/77lm/W. Colour temperature: 3000/4000K. Colour rendering: Ra>80. MacAdams factor: SDCM: 3. Lifetime: L80/B20>50,000, . Light distribution: Direct. Control/Dimming: Trailing edge dimming. Luminiare class: Class II. Housing: Aluminium. Optics: . Height: 222.0mm. Length: 402.0 mm. Width: 240.0 mm. EAN: 7021986239621 The EPD also covers the following products: EAN: 7021986239638 - HERNING WALL MIDI GRAY 3000/4000K EAN: 7021986239690 - HERNING WALL MIDI CORTEN Please note that the above has been calculated with the Norwegian Energy-mix. If you want an EPD with a specific energy-mix, please send us a request.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) can be excluded. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.53295291758 kg
Time representativeness
Data set valid until 2029
Time representativeness description 2024-12-06 - 2029-12-06
Technological representativeness
Technology description including background system Link to product data on our website: https://www.sg-as.com/products/herning-wall/623962/pdf/specification_623962.pdf Link to CE Declaration: https://www.sg-as.com/assets/product/default/data/130060_Herning/50/130060_Herning%20Wall.pdf

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 60.53
  • 0.00257
  • 1.366
  • 0.2691
  • 0.004288
  • 1712
  • 0
  • 0.03388
  • 0.04206
  • 0.05398
  • -12.98
Input
  • 6.79
  • 0
  • 0
  • 0
  • -6.79
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 67.32
  • 0.00257
  • 1.366
  • 0.2691
  • -6.786
  • 1712
  • 0
  • 0.03388
  • 0.04206
  • 0.05398
  • -12.98
Input
  • 359.6
  • 0.2271
  • 13.57
  • 23.69
  • 0.2605
  • 132.4
  • 0
  • 2.993
  • 0.3301
  • 0.3364
  • -39.13
Input
  • 3.753
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -4.396
  • 0
  • 0
Input
  • 363.3
  • 0.2271
  • 13.57
  • 23.69
  • 0.2605
  • 132.4
  • 0
  • 2.993
  • -4.066
  • 0.3364
  • -39.13
Input
  • 2.356
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0005913
  • 0.00587
Input
  • 0.2035
  • 0.00005027
  • 0.001201
  • 0.008868
  • 0.0001422
  • 1.344
  • 0
  • 0.0006626
  • 0.0007404
  • 0.0006987
  • -0.001482
Input
  • 0.1037
  • 0.0004268
  • 0.0113
  • 0.04752
  • 0.0005864
  • 3.349
  • 0
  • 0.005626
  • -0.00002769
  • 0.005219
  • 0.003821
Input
  • 0.2843
  • 0.00002539
  • 0.03702
  • 0.002037
  • 0.0001229
  • 12.79
  • 0
  • 0.0003347
  • 0.000424
  • 0.0003815
  • -0.06643
Output
  • 0.256
  • 0.00002052
  • 0.001875
  • 0.001155
  • 0
  • 0.08488
  • 0
  • 0.0002705
  • 0.00001366
  • 0.05188
  • 0.006641
Output
  • 5.465
  • 0.0109
  • 0.1268
  • 0.7314
  • 1.151
  • 10.18
  • 0
  • 0.1437
  • 0.01845
  • 0.9055
  • -0.8113
Output
  • 0.0008042
  • 0.00000149
  • 0.00001038
  • 0.0001626
  • 0
  • 0.001184
  • 0
  • 0.00001964
  • 6.786E-7
  • 0.00000163
  • -0.0001496
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.04043
  • 0
  • 1.071
  • 0
  • 0
  • 0
  • 1.785
  • 0.000007384
  • -0.0002365
Output
  • 0
  • 0
  • 0.008719
  • 0
  • 0.0004769
  • 0
  • 0
  • 0
  • 0.08233
  • 1.806E-7
  • -0.00003108
Output
  • 0
  • 0
  • 0.01314
  • 0
  • 0.06584
  • 0
  • 0
  • 0
  • 0.1271
  • 0.00001172
  • -0.00007859
Output
  • 0
  • 0
  • 0.1987
  • 0
  • 0.996
  • 0
  • 0
  • 0
  • 1.923
  • 0.0001773
  • -0.001189

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 363.3
  • 0.2271
  • 13.57
  • 23.69
  • 0.2605
  • 132.2
  • 0
  • 2.993
  • 0.33
  • 0.3364
  • -39.13
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.01077
  • 4.123E-7
  • 0.00000474
  • 0.00003197
  • 4.532E-7
  • 0.0007221
  • 0
  • 0.000005434
  • 2.424E-7
  • 1.28E-7
  • -0.0007282
Acidification potential, Accumulated Exceedance (AP)
  • 0.255
  • 0.00004598
  • 0.008011
  • 0.02586
  • 0.00008817
  • 0.07566
  • 0
  • 0.000606
  • 0.0001638
  • 0.00012
  • -0.05109
Global Warming Potential - biogenic (GWP-biogenic)
  • -1.648
  • 0.000005985
  • 0.0003818
  • 0.0005949
  • 1.953
  • 0.2677
  • 0
  • 0.00007889
  • 0.00006209
  • 0.00001695
  • -0.01446
Global Warming Potential - fossil fuels (GWP-fossil)
  • 33.95
  • 0.01537
  • 1.533
  • 1.677
  • 0.01862
  • 9.683
  • 0
  • 0.2026
  • 0.2267
  • 0.0261
  • -3.131
Global Warming Potential - total (GWP-total)
  • 32.39
  • 0.01538
  • 1.534
  • 1.678
  • 1.972
  • 9.991
  • 0
  • 0.2027
  • 0.2268
  • 0.02617
  • -3.191
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.09096
  • 0.000005619
  • 0.0002417
  • 0.0008354
  • 0.000006158
  • 0.03994
  • 0
  • 0.00007407
  • 0.00006311
  • 0.00005587
  • -0.04546
  • 34.33
  • 0.01538
  • 1.449
  • 1.678
  • 0.01863
  • 9.971
  • 0
  • 0.2027
  • 0.2268
  • 0.02828
  • -3.106
Eutrophication potential - freshwater (EP-freshwater)
  • 0.002351
  • 1.442E-7
  • 0.00003405
  • 0.0000107
  • 1.529E-7
  • 0.0006964
  • 0
  • 0.0000019
  • 0.00000103
  • 4.569E-7
  • -0.0002811
Eutrophication potential - marine (EP-marine)
  • 0.03825
  • 0.000009052
  • 0.001655
  • 0.006221
  • 0.00002916
  • 0.008316
  • 0
  • 0.0001193
  • 0.00004217
  • 0.00004837
  • -0.004117
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.4369
  • 0.0001012
  • 0.01823
  • 0.06928
  • 0.0003157
  • 0.1082
  • 0
  • 0.001334
  • 0.0004555
  • 0.00043
  • -0.05044
Photochemical Ozone Creation Potential (POCP)
  • 0.1278
  • 0.0000379
  • 0.004802
  • 0.01872
  • 0.00009075
  • 0.02911
  • 0
  • 0.0004996
  • 0.0001201
  • 0.0001362
  • -0.01542
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.00001278
  • 3.338E-9
  • 2.247E-8
  • 3.696E-7
  • 3.93E-9
  • 6.64E-7
  • 0
  • 4.406E-8
  • 2.261E-9
  • 3.687E-9
  • -0.001233
Water (user) deprivation potential (WDP)
  • 1912
  • 0.07405
  • 2.212
  • 15.69
  • 0.3301
  • 2.304E+4
  • 0
  • 0.9761
  • 3.003
  • 5.8
  • -1345

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.8928
  • 0.0009438
  • 0.01174
  • 0.1027
  • 0.001115
  • 2.398
  • 0
  • 0.01244
  • 0.001602
  • 0.001778
  • -0.1584
Potential incidence of disease due to PM emissions (PM) 2
  • 0.000002302
  • 9.88E-10
  • 1.082E-7
  • 5.93E-8
  • 1.302E-9
  • 5.424E-7
  • 0
  • 1.31E-8
  • 1.023E-9
  • 2.152E-9
  • -2.661E-7
Potential Soil quality index (SQP) 2
  • 119.9
  • 0.1556
  • 2.876
  • 11.43
  • 0.1748
  • 66.57
  • 0
  • 2.051
  • 0.07803
  • 0.7039
  • -7.906
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000001202
  • 1.79E-10
  • 1.881E-8
  • 1.183E-8
  • 4.37E-10
  • 6.771E-7
  • 0
  • 2.381E-9
  • 2.779E-8
  • 5.37E-10
  • -1.672E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 5.192E-8
  • 0
  • 4.3E-10
  • 0
  • 1.1E-11
  • 2.874E-8
  • 0
  • 0
  • 4.71E-10
  • 4.5E-11
  • -7.677E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 1981
  • 0.1841
  • 39.79
  • 16.14
  • 0.3474
  • 602.2
  • 0
  • 2.427
  • 0.9422
  • 402.8
  • -281.1