| Use advice for data set | A1 includes the extraction and production of all raw materials used in the product A2 includes all types of transportation methods used for the raw materials to the production site in Töcksfors, Sweden A3 includes the manufacturing and packaging process of the air handling unit A4 includes the transport to the market/user A5 modules not declared. B1 - B7 modules not declared C1 - C4 includes the use of energy and other auxiliary materials required to demolish the building or construction in which the product is included, as well as transport from the building site to the waste processing facility, distribution of the product to different waste treatment methods and the disposal D includes energy and materials that have achieved a new function and are no longer considered waste |
| Technical purpose of product or process | Flexit Nordic CL2 RER (art. 800210) air handling units have been developed to be energy efficient in Nordic climate. Connection option for kitchen hood via bypass. The unit has high-efficiency rotary heat exchangers, with a temperature efficiency of up to 85%. Low building height makes the unit excellent for ceiling mounting or mounting in cold attic. All Nordic units are controlled as standard via the Flexit GO app and can be supplemented with various accessories, eg. control panel, humidity sensor, pressure sensor for kitchen hood, CO2 sensor etc. The control system is prepared for local demand control. Cooling recovery is a standard feature in the Nordic series. With Flexit GO you can also activate the function free/night cooling. At high humidity, the defrost function ensures operation in cold climates.Can be installed both in cold attics and in suspended ceilings - Low weight and height < 30 cm - Built-in humidity sensor - Configurable door solution - Very quiet, below 35 dB(A) 10m2 Sabine - Control via app and cloud services |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Energy, water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2029 |
| Time representativeness description | "2024-08-12" - "2029-08-12" |
| Technological representativeness | |
| Technology description including background system | Please visit our webpage and find the technical data specification under the product description www.flexit@.com |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2024-09-18T19:56:48 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 6c7a3df5-600e-4f2f-88ef-10ef5cafc406 |
| Date of last revision | 2024-08-07T05:35:29.2377789Z |
| Data set version | 00.04.000 |
| Registration authority | |
| Registration number | NEPD-7226-6608 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle