Process Data set: Prefix PLS 90/2x1,5 (en) en

Key Data Set Information
Location NO
Geographical representativeness description Nordic
Reference year 2025
Name
Prefix PLS 90/2x1,5
Use advice for data set Cradle to Gate. The following stages have been declared: A1-A4
Technical purpose of product or process Prefix PLS 90 is a Pre-wired double insulated power supply cable for transformer - primary and secondary outlet. The construction secure a direct connection including tensile strength relief without extra protection (NEK). Prefix Pre-wired PLS 90 shall is for fixed wiring - above-ground built-in pipes, ducts or in similar closed systems. Cable shall be used according to reference EN 50656-1. Contact with water is not permitted. Insulation is of self-extinguishing and flame retardant material. Fire performance according to CPR EN 50575 class Eca. Excellent sliding properties in corrugated pipes and easy strippable! Construction standard - Pipe: EN 611386-1; EN 61386-22 Pipe designation: ICTA 34423 General: EN50525-1 Specific conductor EN52525-2-31 Specific jacket EN50525-2-11
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Data from material supplier and the LCA generator has been accepted "As-Is" Data from processing TECCON in-house has been repeated ongoingly without major deviations. Figures given in document are worst case values. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. The allocation is made in accordance with the guidelines given in EN 15804. Raw material - Information derived from manufactory and from a LCA generator Processing: Derived from actual measurements during production of the individual units/stages. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. All major materials have been included. Substance representing <1% have not been included. This include folio film for packaging!
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.013577981642 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-04-10 - 2030-04-10
Technological representativeness
Technology description including background system CONDUIT Construction standards EN 611386-1; EN 61386-22 ICTA 34423 Corrugated Conduit Pliable/Self recovering halogen free Polypropylene Compression force 750N Marking EN, Date, and meter marking: 0-100m Temperature - operation -25 to + 90°C Temperature - installation -5 to + 90°C Bending Radius 8 x D Resistant to fire performance Flame retardant, self-extinguishing, low smoke toxic emission Insulations resistance >100M? at 500V in 1 min Test - mechanical Acc. EN 61386-1; EN 61386-22 Test - electrical Acc. EN 61386-1; >2,0kV 50HZ in 15 min CableConstruction standards Factory Standard + EN50525-1 Conductor Stranded annealed cooper wire. EN60228 class 2 Insulation - conductor Coloured special PVC. Conductor marking 1. Blue 2. Brown Conductor laying Cores in parallel Jacket PVC , self-extinguishing and flame retardant material Marking TECCON PLS 90 Ce RoHs Voltage - nominal Uo/U 450/750V Voltage - test - 1min/5min 2000V Max conductor temperature/°C : 90 Resistant to fire performance EN60332-1 CPR EN 50575 compliance Eca DoP 17_005_00 Temperature - operation -30 to 80 °C Temperature - installation -5 to 50 °C Art.nr. 1251518

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 0.5279
  • 0.003025
  • 0.27
  • 0.00395
  • 0.01713
  • 0
  • 0.0004275
  • 0.01983
  • 0.003136
  • -2.653
Input
  • 0.8093
  • 0
  • 0
  • 0
  • -0.7932
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 1.337
  • 0.003025
  • 0.27
  • 0.00395
  • -0.776
  • 0
  • 0.0004275
  • 0.01982
  • 0.003136
  • -2.653
Input
  • 6.42
  • 0.2216
  • 0.05018
  • 0.276
  • 0.1611
  • 0
  • 0.0303
  • 0.164
  • 0.0373
  • -1.37
Input
  • 2.418
  • 0
  • 0
  • 0
  • 0.002371
  • 0
  • 0
  • -2.371
  • 0
  • -0.3023
Input
  • 8.839
  • 0.2216
  • 0.05018
  • 0.276
  • 0.1634
  • 0
  • 0.0303
  • -2.207
  • 0.0373
  • -1.672
Input
  • 0.006715
  • 0
  • 0
  • 0
  • 0.0001497
  • 0
  • 0
  • 0
  • 0.00001328
  • 0.01993
Input
  • 0.01072
  • 0.0001067
  • 0.0002303
  • 0.0001413
  • 0.0002445
  • 0
  • 0.0000153
  • 0.0003617
  • 0.00007321
  • 0.0008645
Input
  • 0.006686
  • 0.0004147
  • 0.0005982
  • 0.0005053
  • 0.0002156
  • 0
  • 0.00005463
  • 0
  • 0.000745
  • -0.1294
Input
  • 0.007084
  • 0.00002263
  • 0.002058
  • 0.00002951
  • 0.0002702
  • 0
  • 0.00000319
  • 0.003683
  • 0.00003911
  • -0.005708
Output
  • 0.003168
  • 0.00001125
  • 0.000429
  • 0.00001423
  • 0.0002173
  • 0
  • 0.000001545
  • 0
  • 0.004724
  • -0.0008071
Output
  • 0.0847
  • 0.009875
  • 0.02958
  • 0.01342
  • 0.03395
  • 0
  • 0.001448
  • 0
  • 0.06718
  • -0.04288
Output
  • 0.00001215
  • 0.000001512
  • 3.275E-7
  • 0.00000188
  • 3.747E-7
  • 0
  • 2.066E-7
  • 0
  • 1.507E-7
  • -0.000002974
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.09655
  • 0
  • 0.05397
  • 0
  • 0
  • 0.0493
  • 0.000003442
  • -0.0007852
Output
  • 0
  • 0
  • 0.01555
  • 0
  • 0.004543
  • 0
  • 0
  • 0.1237
  • 4.196E-7
  • -0.0001249
Output
  • 0
  • 0
  • 0.02388
  • 0
  • 0.008276
  • 0
  • 0
  • 0.1663
  • 0.000008405
  • -0.0002905
Output
  • 0
  • 0
  • 0.3614
  • 0
  • 0.1252
  • 0
  • 0
  • 2.517
  • 0.0001272
  • -0.004394

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 8.703
  • 0.2216
  • 0.05015
  • 0.276
  • 0.208
  • 0
  • 0.03029
  • 0.164
  • 0.03729
  • -1.647
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.00006719
  • 3.806E-7
  • 1.609E-7
  • 5.042E-7
  • 0.00000144
  • 0
  • 5.442E-8
  • 2.505E-7
  • 1.679E-8
  • -0.00006455
Acidification potential, Accumulated Exceedance (AP)
  • 0.02359
  • 0.00008799
  • 0.0000266
  • 0.00005245
  • 0.0004983
  • 0
  • 0.000008213
  • 0.00008822
  • 0.00001516
  • -0.01172
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.04348
  • 0.000005952
  • 0.00004359
  • 0.000007554
  • 0.04958
  • 0
  • 8.192E-7
  • 0.00004863
  • 0.000002251
  • -0.0004758
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.4559
  • 0.01489
  • 0.03996
  • 0.01825
  • 0.01702
  • 0
  • 0.002009
  • 0.2837
  • 0.008379
  • -0.1127
Global Warming Potential - total (GWP-total)
  • 0.4128
  • 0.0149
  • 0.04001
  • 0.01827
  • 0.06661
  • 0
  • 0.002011
  • 0.2837
  • 0.008381
  • -0.1141
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0003702
  • 0.000005813
  • 0.000006996
  • 0.000006496
  • 0.000008512
  • 0
  • 7.023E-7
  • 0.000009274
  • 6.325E-7
  • -0.000956
  • 0.4559
  • 0.0149
  • 0.04001
  • 0.01827
  • 0.01589
  • 0
  • 0.002011
  • 0.284
  • 0.008597
  • -0.07638
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0002289
  • 1.131E-7
  • 1.298E-7
  • 1.458E-7
  • 0.000004758
  • 0
  • 1.578E-8
  • 3.556E-7
  • 6.195E-8
  • -0.00007967
Eutrophication potential - marine (EP-marine)
  • 0.0009281
  • 0.00001978
  • 0.000007134
  • 0.00001038
  • 0.00002283
  • 0
  • 0.000002436
  • 0.00002648
  • 0.000009221
  • -0.0005496
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.01271
  • 0.0002206
  • 0.00007834
  • 0.0001161
  • 0.0002958
  • 0
  • 0.00002694
  • 0.000285
  • 0.00005376
  • -0.008153
Photochemical Ozone Creation Potential (POCP)
  • 0.004088
  • 0.00006772
  • 0.00002076
  • 0.00004447
  • 0.00009426
  • 0
  • 0.000008247
  • 0.000076
  • 0.00001564
  • -0.002242
Depletion potential of the stratospheric ozone layer (ODP)
  • 6.348E-8
  • 3.353E-9
  • 5.49E-10
  • 4.134E-9
  • 1.765E-9
  • 0
  • 4.58E-10
  • 3.945E-9
  • 4.27E-10
  • -0.001853
Water (user) deprivation potential (WDP)
  • 9.07
  • 0.1994
  • 3.689
  • 0.2669
  • 0.3636
  • 0
  • 0.0289
  • 3.142
  • 0.5876
  • -3.404

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.013
  • 0.000967
  • 0.0004964
  • 0.001206
  • 0.0003989
  • 0
  • 0.0001324
  • 0.0007614
  • 0.0001993
  • -0.00362
Potential incidence of disease due to PM emissions (PM) 2
  • 4.917E-8
  • 8.19E-10
  • 2.32E-10
  • 1.117E-9
  • 1.144E-9
  • 0
  • 1.45E-10
  • 5.35E-10
  • 1.85E-10
  • -3.616E-8
Potential Soil quality index (SQP) 2
  • 7.145
  • 0.144
  • 0.02893
  • 0.193
  • 0.165
  • 0
  • 0.02089
  • 0.05702
  • 0.1186
  • -3.79
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 3.672E-7
  • 1.63E-10
  • 2.26E-10
  • 2.23E-10
  • 7.675E-9
  • 0
  • 2.4E-11
  • 1.865E-9
  • 1.44E-10
  • -1.293E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 4.194E-9
  • 0
  • 8E-12
  • 0
  • 8.7E-11
  • 0
  • 0
  • 2E-11
  • 3E-12
  • -1.527E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 174.7
  • 0.1612
  • 0.1909
  • 0.2046
  • 3.959
  • 0
  • 0.02231
  • 7.349
  • 8.311
  • -107.3