Close Go back Collapse all sections
Process Data set: MFP (en) en

Key Data Set Information
Location CZ
Geographical representativeness description Europe.
Reference year 2024
Name
MFP
Technical purpose of product or process For the most demanding requirements of air cleanliness and sterility. Prefilters or final filters for the separation of fine dust and suspended particles. Used for industrial, research, medical, pharmaceutical, and nuclear engineering applications. For more information see: www.trox.de/en/panel-filter/mfp-96487f59177c7166 Mini pleat filter panels MFP for the separation of fine dust and suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply and extract air in ventilation systems. Used as fine dust filters, prefilters or final filters in AHU units; or as particulate filters, main or final filters for highest requirements of air purity and sterility, in areas such as industry, research, medicine, pharmaceuticals, and nuclear technology. Low installation depth due to compact V-design, for systems with high volume flow rates and long filter service lives. Filter media made of high-quality, wet-strength glass fibre papers, with spacers made of thermoplastic hot-melt adhesive. Ideal pleat position and largest possible filter surface allow low initial differential pressure. Mini-Pleat filter panels available in standard and special sizes, in variable pleat depths, filter groups ISO ePM10, ISO ePM2.5, ISO ePM1 (fine dust filters) and EPA, HEPA, ULPA (particulate filters). Depending on the frame design, Mini Pleat filter panels are fitted as standard without seal, with a flat seal on the upstream side, or with a fluid seal. Versions optionally available with foamed continuous seal on one or both sides, with a test groove seal on the upstream side, or with a protection grid, positioned as required. Mini Pleat filter panels used as fine dust filters are certified by Eurovent. Constructions with a frame made of extruded aluminium sections meet the hygiene requirements of VDI 6022. This EPD declares the environmental data of the product series MFP. The following represents a representative dataset of the default variant MFP-H14-ALZ/535x535x78x50/PD/FNU/0/ST.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Ventilation components
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Energy, water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
  • - 1.0 * 1.0 Stück (Number of pieces)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.21268376396 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-01-01" - "2029-01-01"
Technological representativeness
Technology description including background system For technical data see: www.trox.de/en/panel-filter/mfp-96487f59177c7166#technical-information

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 98.18
  • 0.129
  • 0.0003956
  • 0.008061
  • 1.268
  • 0.6672
  • -57.58
Input
  • 4.938
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 103.1
  • 0.129
  • 0.0003956
  • 0.008061
  • 1.268
  • 0.6672
  • -57.58
Input
  • 430.5
  • 9.01
  • 0.07314
  • 0.5631
  • 7.024
  • 2.221
  • -159.7
Input
  • 58.01
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 488.3
  • 9.01
  • 0.07314
  • 0.5631
  • 7.024
  • 2.221
  • -159.7
Input
  • 0.4611
  • 0
  • 0.00003592
  • 0
  • 0
  • 0.0163
  • 0
Input
  • 0.5425
  • 0.004614
  • 0.000009732
  • 0.0002884
  • 0.02797
  • 0.002156
  • -0.0186
Input
  • 0.92
  • 0.0165
  • 0.0001432
  • 0.001031
  • 0
  • 0.1477
  • 0.2223
Input
  • 1.048
  • 0.0009635
  • 0.000003764
  • 0.00006022
  • 0.006519
  • 0.001665
  • -0.3139
Output
  • 0.2656
  • 0.0004647
  • 0.000002153
  • 0.00002904
  • 0
  • 0.7552
  • 0.05187
Output
  • 6.66
  • 0.4382
  • 0.00008659
  • 0.02739
  • 0.755
  • 0.8216
  • -3.679
Output
  • 0.002138
  • 0.00006137
  • 5.078E-7
  • 0.000003836
  • 0
  • 8.743E-9
  • -0.0006479
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.0949
  • 0
  • 0.00003527
  • 0
  • 1.836
  • 4.485E-7
  • 0
Output
  • 0.003595
  • 0
  • 1.093E-7
  • 0
  • 0.76
  • 1.097E-8
  • 0
Output
  • 0.0364
  • 0
  • 3.749E-7
  • 0
  • 0.007591
  • 7.116E-7
  • 0
Output
  • 0.5506
  • 0
  • 0.000005672
  • 0
  • 0.1148
  • 0.00001077
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 486.4
  • 9.009
  • 0.07314
  • 0.5631
  • 7.023
  • 2.219
  • -159.7
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.001888
  • 0.00001646
  • 8.153E-9
  • 0.000001029
  • 0.000005845
  • 0.000001086
  • 0.00001683
Acidification potential, Accumulated Exceedance (AP)
  • 0.1909
  • 0.001713
  • 0.00005559
  • 0.000107
  • 0.002462
  • 0.000928
  • -0.08512
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.5823
  • 0.0002466
  • 9.962E-7
  • 0.00001541
  • 0.004201
  • 0.0001759
  • -0.05739
Global Warming Potential - fossil fuels (GWP-fossil)
  • 28.78
  • 0.5959
  • 0.005314
  • 0.03724
  • 1.689
  • 0.2297
  • -12.6
Global Warming Potential - total (GWP-total)
  • 28.48
  • 0.5963
  • 0.005315
  • 0.03727
  • 1.694
  • 0.2313
  • -12.9
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.2819
  • 0.0002121
  • 4.188E-7
  • 0.00001326
  • 0.0004224
  • 0.00143
  • -0.237
  • 29.17
  • 0.5963
  • 0.005315
  • 0.03727
  • 1.694
  • 0.06242
  • -12.38
Eutrophication potential - freshwater (EP-freshwater)
  • 0.001663
  • 0.000004761
  • 1.934E-8
  • 2.975E-7
  • 0.00004017
  • 0.000007861
  • -0.0004905
Eutrophication potential - marine (EP-marine)
  • 0.03103
  • 0.0003388
  • 0.00002454
  • 0.00002118
  • 0.0005093
  • 0.0002036
  • -0.01079
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.3442
  • 0.00379
  • 0.0002692
  • 0.0002369
  • 0.005737
  • 0.002212
  • -0.1187
Photochemical Ozone Creation Potential (POCP)
  • 0.104
  • 0.001452
  • 0.00007402
  • 0.00009074
  • 0.001607
  • 0.0009633
  • -0.04022
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.000003497
  • 1.35E-7
  • 1.149E-9
  • 8.436E-9
  • 1.918E-7
  • 1.332E-8
  • -0.0000506
Water (user) deprivation potential (WDP)
  • 6492
  • 8.714
  • 0.01554
  • 0.5446
  • 26.02
  • 10.39
  • -7.14E+3

IndicatorUnit Production
A1-A3
Transport
A4
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 2.307
  • 0.03938
  • 0.0003134
  • 0.002461
  • 0.03196
  • 0.005029
  • -0.6895
Potential incidence of disease due to PM emissions (PM) 2
  • 0.000001736
  • 3.648E-8
  • 1.471E-9
  • 2.28E-9
  • 3.776E-8
  • 1.561E-8
  • -8.826E-7
Potential Soil quality index (SQP) 2
  • 131.9
  • 6.302
  • 0.009281
  • 0.3939
  • 2.77
  • 5.899
  • -1.505
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 9.576E-7
  • 7.296E-9
  • 3.6E-11
  • 4.56E-10
  • 9.825E-9
  • 6.8E-9
  • -3.538E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.378E-7
  • 0
  • 0
  • 0
  • 1.609E-9
  • 7.72E-10
  • -3.222E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 1098
  • 6.679
  • 0.03997
  • 0.4174
  • 34.09
  • 70.91
  • -195.8