Close Go back Collapse all sections
Process Data set: IFSI-EMC Pure 1kV 4x16/16mm² FR (en) en

Key Data Set Information
Location FI
Geographical representativeness description Norway
Reference year 2024
Name
IFSI-EMC Pure 1kV 4x16/16mm² FR
Technical purpose of product or process IFSI-EMC PURE 1KV CU Power cable with up to 1 kV operating voltage. Allowed indoors, outdoors and as a ground cable without extra protection. The Cu screen is 100% tight, has low coupling impedance and meets the EMC directive. The 3-conductor is symmetrically constructed and has a CU screen from 1.5mm². Halogen-free cable is recommended used when it is important to avoid the formation of dense smoke and corrosive gases in the event of an overheating or fire. Conductor material Copper Conductor surface: Bare Core insulation material: XLPE Armoring material: Copper, bare Screen construction: Metallized foil Screen material: Copper, bare Concentric conductor: Copper Material inner sheath: Halogen-free polymer Material outer sheath: Halogen-free polymer Cable shape: Round
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.001176226415 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description 2024-09-06 - 2029-09-06
Technological representativeness
Technology description including background system IFSI-EMC Pure 1kV 4x16/16mm² FR SAP code: 20216073 El no. 1003834 STANDARDS APPLIED: HD 604-5D Construction IEC 60502-1 Construction IEC 60228 Class 1 or Class 2 Conductors EN 50575:2014 + A1:2016 CPR standard - Fire properties EN 60754-1 and EN 60754-2 Halogen free properties: EN 60754-1 (pH = 4,3, Conductivity = 10µS), EN 60754-2 ( < 0,5% Halogen) IEC 61034-1, -2 Low smoke properties: IEC 61034-1, -2 (minimum 60% light transmittance)

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 10.81
  • 0.04406
  • 1.034
  • 0.03435
  • 0.2384
  • 0
  • 0
  • 0
  • 0
  • 0
  • 6.574
  • 0
  • 0
  • 0.01177
  • 0.003304
  • 0.0151
  • -3.178
Input
  • 0.03521
  • 0
  • 0
  • 0
  • 0.00002643
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -0.03389
  • 0
  • 0
Input
  • 10.84
  • 0.04406
  • 1.034
  • 0.03435
  • 0.2385
  • 0
  • 0
  • 0
  • 0
  • 0
  • 6.574
  • 0
  • 0
  • 0.01177
  • -0.03058
  • 0.0151
  • -3.178
Input
  • 48.6
  • 4.044
  • 13.2
  • 2.729
  • 1.345
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.5083
  • 0
  • 0
  • 0.8342
  • 0.06238
  • 0.1393
  • -2.067
Input
  • 8.021
  • 0
  • 0
  • 0
  • 0.01261
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -0.04592
  • 0
  • -7.344
  • 0
  • 0
Input
  • 56.62
  • 4.044
  • 13.2
  • 2.729
  • 1.358
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.5083
  • 0
  • -0.04592
  • 0.8342
  • -7.282
  • 0.1393
  • -2.067
Input
  • 0.1454
  • 0
  • 0.002099
  • 0
  • 0.002949
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.05439
Input
  • 0.2362
  • 0.001466
  • 0.0008579
  • 0.001201
  • 0.004789
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.005163
  • 0
  • 0
  • 0.0004213
  • 0.00007215
  • 0.0003132
  • 0.004731
Input
  • 0.009766
  • 0.00429
  • 0.00102
  • 0.004027
  • 0.0003433
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.01286
  • 0
  • 0
  • 0.001504
  • 0
  • 0.0002024
  • -0.1378
Input
  • 0.1476
  • 0.0003307
  • 0.004676
  • 0.0003108
  • 0.003068
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0491
  • 0
  • 0
  • 0.00008785
  • 0.0004904
  • 0.0001793
  • -0.007573
Output
  • 0.02923
  • 0.0001887
  • 0.01226
  • 0.0001494
  • 0.001213
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0003259
  • 0
  • 0
  • 0.00004254
  • 0
  • 0.01893
  • -0.002125
Output
  • 1.368
  • 0.1174
  • 0.06652
  • 0.2374
  • 0.04263
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0391
  • 0
  • 0
  • 0.03987
  • 0
  • 0.4843
  • -0.0992
Output
  • 0.0001923
  • 0.00002783
  • 0.0002245
  • 0.00001863
  • 0.000009079
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000004545
  • 0
  • 0
  • 0.000005688
  • 0
  • 9.599E-7
  • -0.000003996
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.06541
  • 0
  • 0.009602
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.4147
  • 0.00001789
  • -0.002129
Output
  • 0
  • 0
  • 0.05504
  • 0
  • 0.005229
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2064
  • 4.374E-7
  • -0.0002803
Output
  • 0
  • 0
  • 0.03679
  • 0
  • 0.007223
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.3243
  • 0.00002838
  • -0.0006867
Output
  • 0
  • 0
  • 0.5566
  • 0
  • 0.1093
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 4.907
  • 0.0004293
  • -0.01039

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 56.33
  • 4.044
  • 13.2
  • 2.729
  • 1.5
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.5076
  • 0
  • 0
  • 0.8342
  • 0.06219
  • 0.1393
  • -2.067
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.001341
  • 0.000005147
  • 0.000001828
  • 0.000002996
  • 0.00002699
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000002773
  • 0
  • 0
  • 0.000001498
  • 4.791E-8
  • 4.638E-8
  • -0.0001751
Acidification potential, Accumulated Exceedance (AP)
  • 0.1752
  • 0.005064
  • 0.0004553
  • 0.0007375
  • 0.003626
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0002905
  • 0
  • 0
  • 0.0002261
  • 0.000101
  • 0.00004711
  • -0.03145
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.05471
  • 0.00009801
  • 0.00554
  • 0.00007201
  • 0.001586
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.001028
  • 0
  • 0
  • 0.00002256
  • 0.01525
  • 0.003699
  • -0.000923
Global Warming Potential - fossil fuels (GWP-fossil)
  • 3.808
  • 0.2867
  • 0.06074
  • 0.1754
  • 0.09505
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.03718
  • 0
  • 0
  • 0.05532
  • 0.492
  • 0.02687
  • -0.2143
Global Warming Potential - total (GWP-total)
  • 3.867
  • 0.2869
  • 0.06637
  • 0.1756
  • 0.09673
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.03836
  • 0
  • 0
  • 0.05536
  • 0.5073
  • 0.03057
  • -0.2164
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.004079
  • 0.0001362
  • 0.00008336
  • 0.00005122
  • 0.00008653
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0001534
  • 0
  • 0
  • 0.00001934
  • 0.000001769
  • 0.000002021
  • -0.001176
  • 3.86
  • 0.2869
  • 0.06528
  • 0.1756
  • 0.09646
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.03829
  • 0
  • 0
  • 0.05536
  • 0.5006
  • 0.03192
  • -0.1172
Eutrophication potential - freshwater (EP-freshwater)
  • 0.001468
  • 0.000001737
  • 0.000002106
  • 0.000001338
  • 0.00002945
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000002674
  • 0
  • 0
  • 4.344E-7
  • 8.618E-8
  • 9.575E-8
  • -0.0002129
Eutrophication potential - marine (EP-marine)
  • 0.01084
  • 0.001336
  • 0.0001425
  • 0.0002218
  • 0.000251
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00003193
  • 0
  • 0
  • 0.00006707
  • 0.00004825
  • 0.00004523
  • -0.001359
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.1591
  • 0.01482
  • 0.001591
  • 0.002452
  • 0.003553
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0004157
  • 0
  • 0
  • 0.0007417
  • 0.0004977
  • 0.0001885
  • -0.02071
Photochemical Ozone Creation Potential (POCP)
  • 0.04101
  • 0.003911
  • 0.0003782
  • 0.0007886
  • 0.0009184
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0001118
  • 0
  • 0
  • 0.0002271
  • 0.0001199
  • 0.00005928
  • -0.005628
Depletion potential of the stratospheric ozone layer (ODP)
  • 2.76E-7
  • 6.206E-8
  • 5.54E-8
  • 4.054E-8
  • 8.286E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.55E-9
  • 0
  • 0
  • 1.261E-8
  • 9.59E-10
  • 1.756E-9
  • -0.002073
Water (user) deprivation potential (WDP)
  • 219.2
  • 2.592
  • 6.345
  • 2.093
  • 4.647
  • 0
  • 0
  • 0
  • 0
  • 0
  • 88.48
  • 0
  • 0
  • 0.7958
  • 0.403
  • 2.792
  • 5.111

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.2136
  • 0.01756
  • 0.5827
  • 0.01193
  • 0.0164
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.009209
  • 0
  • 0
  • 0.003646
  • 0.0001515
  • 0.0008464
  • -0.004661
Potential incidence of disease due to PM emissions (PM) 2
  • 4.709E-7
  • 1.492E-8
  • 6.738E-9
  • 1.544E-8
  • 1.001E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.083E-9
  • 0
  • 0
  • 3.983E-9
  • 4.43E-10
  • 8.56E-10
  • -7.661E-8
Potential Soil quality index (SQP) 2
  • 38.86
  • 1.852
  • 4.885
  • 3.13
  • 0.9442
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2556
  • 0
  • 0
  • 0.5751
  • 0.01099
  • 0.3369
  • -6.363
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000002816
  • 3.076E-9
  • 2.453E-9
  • 1.93E-9
  • 5.648E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.6E-9
  • 0
  • 0
  • 6.64E-10
  • 1.152E-9
  • 1.76E-10
  • -3.494E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 3.721E-8
  • 0
  • 9.9E-11
  • 0
  • 7.47E-10
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.1E-10
  • 0
  • 0
  • 0
  • 2.5E-11
  • 8E-12
  • -4.092E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 1985
  • 2.7
  • 4.72
  • 1.996
  • 43.3
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.312
  • 0
  • 0
  • 0.6144
  • 0.8775
  • 171.2
  • -289.3