Close Go back Collapse all sections
Process Data set: RK 25/3G 16mm² (en) en

Key Data Set Information
Location NO
Geographical representativeness description Norge
Reference year 2025
Name
RK 25/3G 16mm²
Use advice for data set Cradle to Gate. The following stages have been declared: A1-A4
Technical purpose of product or process Pre-Wired RK 90 H05V2-K or RK 90 H07V2-K - Cable in corrugated, Halogen free pliable / self-recovering conduit acc. to EN 61386-1 and EN 61386-22. H07V2-K insulated wire. The solution may be installed in open or closed environment, behind ceiling, in wall or below deck - embedded in concrete. Cable shall be used according to reference EN 50565-1 and EN 50565-2-6A/B. Contact with water is not permitted. Fire performance according to CPR EN 50575. The conduit material is a halogen free, flame retantant, selfextinguishing polypropylene with low toxid and smoke emission.suitable for protected installation in lighting and control applications. Specially designed for inside switching or control equipment boards and distribution cabinets. In general for fixed wiring in above-ground or built-in pipes, ducts or in similar closed systems. May replace double-insulated wires under certain conditions ref. IEC 61439-1. Cable shall be used according to reference EN 50565-1 and EN 50565-2-7A/B. Contact with water is not permitted. Insulation is of self-extinguishing and flame retardant material. Fire performance according to CPR EN 50575. Excellent sliding properties in corrugated pipes and easy strippable! Construction standard- Cable: EN 50525-1; EN 50525-2-31; EN 61386-1; EN 61386-22
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Data from material supplier and the LCA generator has been accepted "As-Is" Data from processing TECCON in-house has been repeated ongoingly without major deviations. Figures given in document are worst case values. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. The allocation is made in accordance with the guidelines given in EN 15804. Raw material - Information derived from manufactory and from a LCA generator Processing: Derived from actual measurements during production of the individual units/stages. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. All major materials have been included. Substance representing <1% have not been included. This include folio film for packaging!
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.14056166678 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-05-07 - 2030-05-07
Technological representativeness
Technology description including background system Construction standards EN 50525-1; EN 50525-2-31; EN 61386-1; EN 61386-22 Conductor Fine stranded copper wire IEC 60228 Class 5 Insulation - conductor PVC TI 1 Conductor color - Cenelec G/G; Light Blue; Brown; Black; White; Orange; Dark Blue; Dark Blue; Red ; B/R and B/W Marking Wire: TECCON H07V2-K; Packaging: acc. LVD Voltage - nominal Uo/U 450/750V Voltage - test 2kV Temperature classification 90° Temperature Max - Short circuit 250° Resistant to fire performance IEC 60332-1-2 CPR EN 50575 compliance Eca DoP 17_0001_00 Temperature - operation -5 - 70°C Temperature - installation 5 - 40°C Temperature - installed -30 to +70 CPR EN 50575 compliance Eca DOP 17_0001_00

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 7.451
  • 0.006303
  • 0.03906
  • 0.02543
  • 0.01777
  • 0
  • 0.002756
  • 0.02164
  • 0.01011
  • -2.671
Input
  • 4.719
  • 0
  • 0
  • 0
  • -4.711
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 12.17
  • 0.006303
  • 0.03906
  • 0.02543
  • -4.693
  • 0
  • 0.002756
  • 0.02164
  • 0.01011
  • -2.671
Input
  • 44.75
  • 0.5563
  • 0.00331
  • 1.777
  • 0.2295
  • 0
  • 0.1953
  • 0.1739
  • 0.09163
  • -4.703
Input
  • 4.794
  • 0
  • 0
  • 0
  • 0.0003399
  • 0
  • 0
  • -4.753
  • 0
  • -0.5274
Input
  • 49.55
  • 0.5563
  • 0.00331
  • 1.777
  • 0.2298
  • 0
  • 0.1953
  • -4.579
  • 0.09163
  • -5.231
Input
  • 0.09218
  • 0
  • 0
  • 0
  • 0.0002398
  • 0
  • 0
  • 0
  • 0.00002372
  • 0.1262
Input
  • 0.03324
  • 0.0002055
  • 0.00003083
  • 0.0009098
  • 0.0001941
  • 0
  • 0.00009863
  • 0.0003928
  • 0.0002161
  • 0.01089
Input
  • 0.06152
  • 0.001164
  • 0.00007699
  • 0.003253
  • 0.0009324
  • 0
  • 0.0003521
  • 0
  • 0.0004157
  • -0.03885
Input
  • 0.06128
  • 0.00004757
  • 0.0002919
  • 0.00019
  • 0.000278
  • 0
  • 0.00002056
  • 0.004039
  • 0.0001117
  • -0.01235
Output
  • 0.03944
  • 0.00002706
  • 0.000003472
  • 0.00009162
  • 0.0001588
  • 0
  • 0.000009959
  • 0
  • 0.008084
  • -0.004913
Output
  • 1.041
  • 0.01629
  • 0.001187
  • 0.0864
  • 0.344
  • 0
  • 0.009333
  • 0
  • 0.2584
  • -0.2131
Output
  • 0.0000915
  • 0.000003818
  • 2.752E-8
  • 0.0000121
  • 3.18E-7
  • 0
  • 0.000001331
  • 0
  • 5.46E-7
  • -0.000005757
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.001209
  • 0
  • 0.01477
  • 0
  • 0
  • 0.2968
  • 0.000007292
  • -0.004947
Output
  • 0
  • 0
  • 0.00005745
  • 0
  • 0.3404
  • 0
  • 0
  • 0.0966
  • 7.772E-7
  • -0.000689
Output
  • 0
  • 0
  • 0.00008828
  • 0
  • 0.2386
  • 0
  • 0
  • 0.1187
  • 0.00001683
  • -0.001661
Output
  • 0
  • 0
  • 0.001336
  • 0
  • 3.61
  • 0
  • 0
  • 1.795
  • 0.0002546
  • -0.02513

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 49.31
  • 0.5563
  • 0.003306
  • 1.776
  • 0.2366
  • 0
  • 0.1953
  • 0.1738
  • 0.09163
  • -5.186
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0009592
  • 7.406E-7
  • 1.697E-8
  • 0.000003246
  • 0.000002542
  • 0
  • 3.508E-7
  • 2.723E-7
  • 3.368E-8
  • -0.000406
Acidification potential, Accumulated Exceedance (AP)
  • 0.3388
  • 0.0006043
  • 0.00000183
  • 0.0003377
  • 0.000917
  • 0
  • 0.00005294
  • 0.00008446
  • 0.00003295
  • -0.07263
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.4356
  • 0.0000142
  • 0.000006117
  • 0.00004863
  • 0.5155
  • 0
  • 0.00000528
  • 0.00005275
  • 0.000002306
  • -0.002178
Global Warming Potential - fossil fuels (GWP-fossil)
  • 3.732
  • 0.03964
  • 0.000375
  • 0.1175
  • 0.02026
  • 0
  • 0.01295
  • 0.2114
  • 0.01463
  • -0.4756
Global Warming Potential - total (GWP-total)
  • 3.3
  • 0.03969
  • 0.000382
  • 0.1176
  • 0.5357
  • 0
  • 0.01296
  • 0.2115
  • 0.01464
  • -0.4787
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.00318
  • 0.00002169
  • 9.18E-7
  • 0.00004182
  • 0.00001127
  • 0
  • 0.000004527
  • 0.00001009
  • 0.000001467
  • -0.0008885
  • 3.799
  • 0.03969
  • 0.0003816
  • 0.1176
  • 0.02016
  • 0
  • 0.01296
  • 0.2118
  • 0.01525
  • -0.2473
Eutrophication potential - freshwater (EP-freshwater)
  • 0.003315
  • 2.507E-7
  • 1.606E-8
  • 9.387E-7
  • 0.000008338
  • 0
  • 1.017E-7
  • 3.833E-7
  • 9.443E-8
  • -0.0004895
Eutrophication potential - marine (EP-marine)
  • 0.01143
  • 0.0001382
  • 2.259E-7
  • 0.00006681
  • 0.00006169
  • 0
  • 0.0000157
  • 0.00002308
  • 0.00002081
  • -0.003026
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.1633
  • 0.001539
  • 0.000002858
  • 0.0007474
  • 0.0007587
  • 0
  • 0.0001736
  • 0.000248
  • 0.0001268
  • -0.04668
Photochemical Ozone Creation Potential (POCP)
  • 0.05174
  • 0.0004204
  • 7.734E-7
  • 0.0002863
  • 0.0002192
  • 0
  • 0.00005316
  • 0.00006787
  • 0.00003746
  • -0.01272
Depletion potential of the stratospheric ozone layer (ODP)
  • 3.084E-7
  • 9.688E-9
  • 1.9E-11
  • 2.662E-8
  • 2.538E-9
  • 0
  • 2.952E-9
  • 4.266E-9
  • 1.106E-9
  • -0.000899
Water (user) deprivation potential (WDP)
  • 8.975
  • 0.3603
  • 0.526
  • 1.718
  • 0.2801
  • 0
  • 0.1863
  • 3.447
  • 1.877
  • 20.19

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.09282
  • 0.002411
  • 0.00005594
  • 0.007765
  • 0.0006977
  • 0
  • 0.0008536
  • 0.0008271
  • 0.0005529
  • -0.00651
Potential incidence of disease due to PM emissions (PM) 2
  • 6.159E-7
  • 1.308E-9
  • 1.3E-11
  • 7.193E-9
  • 2.486E-9
  • 0
  • 9.32E-10
  • 5.29E-10
  • 5.18E-10
  • -1.519E-7
Potential Soil quality index (SQP) 2
  • 45.92
  • 0.2575
  • 0.001712
  • 1.243
  • 0.1994
  • 0
  • 0.1346
  • 0.06197
  • 0.2257
  • -9.663
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.000005459
  • 2.62E-10
  • 1.5E-11
  • 1.439E-9
  • 1.417E-8
  • 0
  • 1.55E-10
  • 1.969E-9
  • 2.02E-10
  • -8.068E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 6.15E-8
  • 0
  • 1E-12
  • 0
  • 1.66E-10
  • 0
  • 0
  • 1.9E-11
  • 8E-12
  • -9.423E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 2.56E+3
  • 0.3779
  • 0.01423
  • 1.317
  • 6.83
  • 0
  • 0.1438
  • 8.077
  • 101.1
  • -667.2