Close Go back Collapse all sections
Process Data set: LAPP ÖLFLEX® CLASSIC 130 H 4G1,5 Elnr 1070950 (en) en

Key Data Set Information
Location FR
Geographical representativeness description Norway
Reference year 2025
Name
LAPP ÖLFLEX® CLASSIC 130 H 4G1,5 Elnr 1070950
Use advice for data set 1m LAPP ÖLFLEX® CLASSIC 130 H 4G1,5mm2 El.nr: 1070950
Technical purpose of product or process ÖLFLEX CLASSIC 130 H are halogen free, highly flame retardant control cables designed for the European and North American market, for occasional flexible use and fixed installation subject to normal mechanical load conditions. They are also suitable for use in dry or damp areas. Considering the temperature range, a temporary outdoor use is possible. They are suitable for occasional, non-automated movements. The maximum tensile load is 15 N/mm² of conductor cross-section during installation and operation. Compulsory guidance is not permitted. Application range: Public buildings, airports, railway stations, plant engineering and construction, air conditioning systems and particularly where human and animal life as well as valuable property are exposed to high risk of fire hazards. In the event of a fire minimal toxic and no corrosive gases occur. USE according to UL: FRPE sheathed cable for internal wiring of appliance Design Design acc. to UL AWM Style 10701 and 21217, UL 758 and based on EN 50525-3-11 Certification UL AWM Style 10701 and 21217* (File No. E63634), UL 758 DNV GL (Certificate No. TAE00002RJ) VDE certified: Supply cable with improved characteristics in the case of fire EN 13501-6 and EN 50575 Classification of fire behaviour (article/dimension range see www.lappkabel.com/cpr) *Style change: UL Style 21089 replaced by Style 21217 (approx. February 2018) Conductor fine wire strands of bare copper, acc. to IEC 60228 resp. EN 60228, Class 5 Insulation halogen free compound TI6, acc. to EN 50363-7, with increased requirements Core identification code acc. to VDE 0293-1, with or without GN/YE ground conductor black cores with white numbers acc. to DIN EN 50334 Stranding cores are stranded in layers Wrapping wrapping optional (fleece tape or plastic foil) Outer sheath halogen free compound TM7 acc. to EN 50363-8 with increased requirements Colour: Silver Grey, similar RAL 7001
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.002067083335 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-04-30 - 2030-04-30
Technological representativeness
Technology description including background system Electrical properties at 20 °C Nominal voltage EN U0/U: 300/500 V UL: 600 V Test voltage core /core: 4000 V AC Mechanical and thermal properties Minimum bending radius occasional flexing: 15 x outer diameter fixed installation: 4 x outer diameter Temperature range occasional flexing (EN): -25°C up to +70°C max. conductor temp. occasional flexing (UL): up to +75°C max. conductor temp. fixed installation (EN): -40°C up to +80°C max. conductor temp. fixed installation (UL): up to +75°C max. conductor temp. Flammability flame retardant acc. to IEC 60332-1-2 resp. EN 60332-1-2 UL: Horizontal flame test acc. to UL 1581 §1090 no flame-propagation acc. to IEC 60332-3-22 resp. EN 60332-3-22 acc. to IEC 60332-3-24 resp. EN 60332-3-24 or acc. to IEC 60332-3-25 resp. EN 60332-3-25 Halogen free acc. to IEC 60754-1 resp. EN 60754-1 Corrosivity of gases acc. to IEC 60754-2 resp. EN 60754-2 Smoke density acc. to IEC 61034-2 resp. EN 61034-2 Toxicity acc. to EN 50306-1 (= 6) UV resistance acc. to EN 50620 acc. to EN ISO 4892-2-2013, method A (change of colour allowed Ozone resistance acc. to EN 50396, method B . Tests acc. to IEC 60811 resp. EN 60811, EN 50395, EN 50396, UL 1581 General requirements These cables are conform to the EU-Directive 2014/35/EU (Low Voltage Directive). A part of these cables (see www.lappkabel.com/cpr) are classified in accordance with the EU-Regulation no. 305/2011 (CPR). Environmental information These cables meet the substance-specific requirements of the EU Directive 2011/65/EU (RoHS)

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 0.9121
  • 0.002192
  • 0.2514
  • 0.004416
  • 0.05405
  • 0
  • 0.0003306
  • 0.0004801
  • 0.00145
  • -0.6685
Input
  • 0.0694
  • 0
  • 0
  • 0
  • -0.06593
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.9815
  • 0.002192
  • 0.2514
  • 0.004416
  • -0.01188
  • 0
  • 0.0003306
  • 0.0004801
  • 0.00145
  • -0.6685
Input
  • 4.288
  • 0.1531
  • 1.654
  • 0.3511
  • 0.3234
  • 0
  • 0.02309
  • 0.008625
  • 0.01607
  • -0.8692
Input
  • 0.8627
  • 0
  • 0
  • 0
  • 0.02394
  • 0
  • 0
  • -1.314
  • 0
  • 0
Input
  • 5.15
  • 0.1531
  • 1.654
  • 0.3511
  • 0.3473
  • 0
  • 0.02309
  • -1.306
  • 0.01607
  • -0.8692
Input
  • 0.00995
  • 0
  • 0
  • 0
  • 0.0004276
  • 0
  • 0
  • 0
  • 0.000001153
  • 0.02666
Input
  • 0.02411
  • 0.00007841
  • 0.001814
  • 0.0001545
  • 0.00113
  • 0
  • 0.00001183
  • 0.00001031
  • 0.00003007
  • 0.002475
Input
  • 0.000561
  • 0.0002804
  • 0.004628
  • 0.0005178
  • 0.0003194
  • 0
  • 0.00004229
  • 0
  • 0.00001657
  • -0.01481
Input
  • 0.005668
  • 0.00001637
  • 0.001526
  • 0.00003995
  • 0.0003896
  • 0
  • 0.00000247
  • 0.00007294
  • 0.00002051
  • -0.002641
Output
  • 0.003242
  • 0.000007896
  • 0.003326
  • 0.00001921
  • 0.0003734
  • 0
  • 0.000001191
  • 0
  • 0.0008799
  • -0.001035
Output
  • 0.1346
  • 0.007446
  • 0.01596
  • 0.03052
  • 0.01467
  • 0
  • 0.001123
  • 0
  • 0.06019
  • -0.04523
Output
  • 0.00001801
  • 0.000001043
  • 0.00002099
  • 0.000002397
  • 0.000002021
  • 0
  • 1.573E-7
  • 0
  • 1.089E-7
  • -0.000001205
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.01209
  • 0
  • 0.002015
  • 0
  • 0
  • 0.0342
  • 0.000003319
  • -0.001043
Output
  • 0
  • 0
  • 0.01426
  • 0
  • 0.005672
  • 0
  • 0
  • 0.0265
  • 8.117E-8
  • -0.0001374
Output
  • 0
  • 0
  • 0.00873
  • 0
  • 0.004423
  • 0
  • 0
  • 0.04071
  • 0.000005266
  • -0.0003366
Output
  • 0
  • 0
  • 0.1321
  • 0
  • 0.06692
  • 0
  • 0
  • 0.616
  • 0.00007966
  • -0.005093

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 5.148
  • 0.1531
  • 1.654
  • 0.3511
  • 0.3698
  • 0
  • 0.02309
  • 0.008624
  • 0.01607
  • -0.8694
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0001217
  • 2.797E-7
  • 3.713E-7
  • 3.851E-7
  • 0.000005172
  • 0
  • 4.219E-8
  • 6.861E-9
  • 5.304E-9
  • -0.00008575
Acidification potential, Accumulated Exceedance (AP)
  • 0.01334
  • 0.0000291
  • 0.00008092
  • 0.0000696
  • 0.0005775
  • 0
  • 0.000004389
  • 0.00001375
  • 0.000005414
  • -0.01533
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.001827
  • 0.000004191
  • 0.001574
  • 0.000009258
  • 0.007532
  • 0
  • 6.321E-7
  • 0.000001363
  • 3.779E-7
  • -0.0004317
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.3172
  • 0.01013
  • 0.02351
  • 0.02161
  • 0.0201
  • 0
  • 0.001527
  • 0.06274
  • 0.004555
  • -0.095
Global Warming Potential - total (GWP-total)
  • 0.3157
  • 0.01013
  • 0.0251
  • 0.02163
  • 0.02765
  • 0
  • 0.001528
  • 0.06274
  • 0.004555
  • -0.09566
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0003077
  • 0.000003604
  • 0.00001437
  • 0.000006585
  • 0.00001726
  • 0
  • 5.436E-7
  • 2.543E-7
  • 2.102E-7
  • -0.0002296
  • 0.3229
  • 0.01013
  • 0.02478
  • 0.02163
  • 0.02036
  • 0
  • 0.001528
  • 0.06273
  • 0.003498
  • -0.04719
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0001081
  • 8.09E-8
  • 5.799E-7
  • 1.72E-7
  • 0.000004661
  • 0
  • 1.22E-8
  • 1.209E-8
  • 9.761E-9
  • -0.0001035
Eutrophication potential - marine (EP-marine)
  • 0.0009012
  • 0.000005758
  • 0.00001773
  • 0.00001524
  • 0.00004274
  • 0
  • 8.685E-7
  • 0.000006576
  • 0.000006334
  • -0.0006389
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.01321
  • 0.00006441
  • 0.0001678
  • 0.00017
  • 0.0006032
  • 0
  • 0.000009714
  • 0.00006739
  • 0.00002168
  • -0.009858
Photochemical Ozone Creation Potential (POCP)
  • 0.003357
  • 0.00002467
  • 0.0000467
  • 0.00006675
  • 0.0001556
  • 0
  • 0.000003721
  • 0.00001625
  • 0.000007057
  • -0.002678
Depletion potential of the stratospheric ozone layer (ODP)
  • 2.801E-8
  • 2.294E-9
  • 7.578E-9
  • 5.211E-9
  • 4.224E-9
  • 0
  • 3.46E-10
  • 1.36E-10
  • 2.08E-10
  • -0.0002822
Water (user) deprivation potential (WDP)
  • 20.93
  • 0.1481
  • 25.02
  • 0.2692
  • 2.202
  • 0
  • 0.02234
  • 0.06223
  • 0.2676
  • 4.299

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.01911
  • 0.0006692
  • 0.01631
  • 0.001534
  • 0.001805
  • 0
  • 0.0001009
  • 0.00002169
  • 0.00009178
  • -0.001365
Potential incidence of disease due to PM emissions (PM) 2
  • 3.708E-8
  • 6.2E-10
  • 4.91E-10
  • 1.985E-9
  • 1.838E-9
  • 0
  • 9.4E-11
  • 6E-11
  • 1.01E-10
  • -3.253E-8
Potential Soil quality index (SQP) 2
  • 3.939
  • 0.1071
  • 0.09679
  • 0.4024
  • 0.2101
  • 0
  • 0.01615
  • 0.001574
  • 0.04534
  • -2.156
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 2.204E-7
  • 1.24E-10
  • 4.46E-10
  • 2.48E-10
  • 9.144E-9
  • 0
  • 1.9E-11
  • 1.65E-10
  • 1.8E-11
  • -1.705E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 2.979E-9
  • 0
  • 1.8E-11
  • 0
  • 1.22E-10
  • 0
  • 0
  • 4E-12
  • 1E-12
  • -1.991E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 160.9
  • 0.1135
  • 0.594
  • 0.2567
  • 7.397
  • 0
  • 0.01712
  • 0.1326
  • 14.13
  • -141.1