Close Go back Collapse all sections
Process Data set: FXQJ/IFSI EMC 4x240/120 0,6/1kV Dca (en) en

Key Data Set Information
Location SE
Geographical representativeness description Northern Europe
Reference year 2024
Name
FXQJ/IFSI EMC 4x240/120 0,6/1kV Dca
Technical purpose of product or process Cables according to this standard are halogen-free and flame retardant. In case of fire, only smoke free of corrosive gases and with low smoke density are emitted. Intended for permanent installation in- and outdoors, in ground, in water and in pipes. Caution shall be taken into account if plowing. Installation of the product should only be carried out by personnel trained and qualified for electrical works. The product is designed according to recognized standards. Applicable rules of installation must be applied at all times. 1. Copper conductor 2. XLPE insulation 3. Bedding 4. Concentric copper conductor with counterhelix 5. Halogen-free flame retardant polyolefine sheath
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-05-07" - "2029-05-07"
Technological representativeness
Technology description including background system Norm (standard): SS4241418 Rated voltage Uo/U: 0,6/1 kV Test voltage: 15 (DC) kV Maximal short-circuit temperature: 250 °C Maximal operating conductor temperature: 90 °C Temperature range: from -20 up to +70 °C Min. temperature for laying and manipulation: -20 °C Min. storage temperature: -30 °C Self-extinguishing of one cable: IEC 60332-1 Smoke density: IEC 61034 Corrosivity of emitted gases: EN 60754-1 Conductivity - pH change : EN 60754-2 CPR-Classification (reaction on fire): Dca-s2,d2,a2 UV stability: Yes Max. permitted pulling force: 50 N/mm2 Radius of bend minimal: 8 x D mm Packaging: drum Production site: NKT Falun RoHS: Yes REACH: Yes CE Conformity: Yes LVD Conformity: Yes

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 124.7
  • 0.3032
  • 35.74
  • 0.2669
  • 3.228
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2003
  • 0
  • 0
  • 0.1144
  • 0.007807
  • 0.1846
  • -39.8
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 124.7
  • 0.3032
  • 35.74
  • 0.2669
  • 3.228
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2003
  • 0
  • 0
  • 0.1144
  • 0.007805
  • 0.1846
  • -39.8
Input
  • 890.3
  • 21.26
  • 65.88
  • 18.65
  • 19.96
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2068
  • 0
  • 0
  • 7.992
  • 0.1614
  • 1.413
  • -81.37
Input
  • 32.72
  • 0
  • 0
  • 0
  • 0.03117
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -31.17
  • 0
  • 0
Input
  • 923.1
  • 21.26
  • 65.88
  • 18.65
  • 20.03
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2068
  • 0
  • 0
  • 7.992
  • -31
  • 1.413
  • -81.37
Input
  • 2.121
  • 0
  • 0
  • 0
  • 0.04281
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.01927
  • 2.625
Input
  • 0.5794
  • 0.01084
  • 0.1221
  • 0.00955
  • 0.01453
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.002023
  • 0
  • 0
  • 0.004093
  • 0.0001765
  • 0.003829
  • 0.2483
Input
  • 1.427
  • 0.03868
  • -0.18
  • 0.03415
  • 0.02641
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.01463
  • 0
  • 0.001067
  • 0.08417
Input
  • 1.322
  • 0.002266
  • 0.0864
  • 0.001994
  • 0.02832
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000911
  • 0
  • 0
  • 0.0008547
  • 0.001113
  • 0.001842
  • -0.2287
Output
  • 0.7326
  • 0.001095
  • 0.2684
  • 0.0009617
  • 0.02311
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00001908
  • 0
  • 0
  • 0.0004122
  • 0
  • 0.1513
  • -0.1017
Output
  • 24.18
  • 1.028
  • 0.5692
  • 0.9069
  • 0.6236
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.001264
  • 0
  • 0
  • 0.3887
  • 0
  • 4.492
  • -4.353
Output
  • 0.001881
  • 0.0001448
  • 0.0009699
  • 0.000127
  • 0.00006273
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000002133
  • 0
  • 0
  • 0.00005444
  • 0
  • 0.000009813
  • -0.00009658
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.01173
  • 0
  • 0.1159
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 5.77
  • 0.00008833
  • -0.1027
Output
  • 0
  • 0
  • 1.078
  • 0
  • 0.01171
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.5851
  • 0.0004871
  • -0.01353
Output
  • 0
  • 0
  • 0.6328
  • 0
  • 0.03259
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.9902
  • 0.004397
  • -0.03314
Output
  • 0
  • 0
  • 9.574
  • 0
  • 0.4931
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 14.98
  • 0.06652
  • -0.5014

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 921.3
  • 21.26
  • 65.74
  • 18.65
  • 20.58
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2036
  • 0
  • 0
  • 7.991
  • 0.1614
  • 1.413
  • -81.39
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.02253
  • 0.00003866
  • 0.000006309
  • 0.00003407
  • 0.0004522
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.172E-7
  • 0
  • 0
  • 0.0000146
  • 1.167E-7
  • 4.671E-7
  • -0.00844
Acidification potential, Accumulated Exceedance (AP)
  • 8.179
  • 0.004368
  • 0.00382
  • 0.003544
  • 0.1638
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00003476
  • 0
  • 0
  • 0.001519
  • 0.0002715
  • 0.0004757
  • -1.507
Global Warming Potential - biogenic (GWP-biogenic)
  • 1.706
  • 0.000581
  • 0.2147
  • 0.0005104
  • 0.03846
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0001377
  • 0
  • 0
  • 0.0002188
  • 0.00002396
  • 0.000006206
  • -0.04189
Global Warming Potential - fossil fuels (GWP-fossil)
  • 77.18
  • 1.408
  • 1.241
  • 1.233
  • 1.654
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.007536
  • 0
  • 0
  • 0.5285
  • 1.532
  • 0.1225
  • -9.058
Global Warming Potential - total (GWP-total)
  • 78.95
  • 1.409
  • 1.794
  • 1.234
  • 1.701
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.008086
  • 0
  • 0
  • 0.5289
  • 1.532
  • 0.1226
  • -9.113
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.06419
  • 0.0005039
  • 0.3377
  • 0.000439
  • 0.008083
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0004128
  • 0
  • 0
  • 0.0001881
  • 0.00000425
  • 0.00002287
  • -0.01246
  • 78.77
  • 1.409
  • 1.742
  • 1.234
  • 1.693
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.01096
  • 0
  • 0
  • 0.5289
  • 1.532
  • 0.06788
  • -4.345
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0806
  • 0.0000112
  • 0.00003366
  • 0.000009853
  • 0.001613
  • 0
  • 0
  • 0
  • 0
  • 0
  • 4.985E-7
  • 0
  • 0
  • 0.000004223
  • 2.16E-7
  • 0.000001068
  • -0.01016
Eutrophication potential - marine (EP-marine)
  • 0.2637
  • 0.0008826
  • 0.001329
  • 0.0007013
  • 0.00534
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000005491
  • 0
  • 0
  • 0.0003006
  • 0.00013
  • 0.0002399
  • -0.06211
Eutrophication potential - terrestrial (EP-terrestrial)
  • 3.797
  • 0.009866
  • 0.01341
  • 0.007844
  • 0.07663
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00007373
  • 0
  • 0
  • 0.003362
  • 0.001356
  • 0.001916
  • -0.9621
Photochemical Ozone Creation Potential (POCP)
  • 1.202
  • 0.003657
  • 0.00335
  • 0.003005
  • 0.02425
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00001727
  • 0
  • 0
  • 0.001288
  • 0.0003262
  • 0.0005567
  • -0.2613
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.000004464
  • 3.186E-7
  • 2.96E-7
  • 2.794E-7
  • 1.076E-7
  • 0
  • 0
  • 0
  • 0
  • 0
  • 8.15E-10
  • 0
  • 0
  • 1.197E-7
  • 2.368E-9
  • 1.731E-8
  • -0.006328
Water (user) deprivation potential (WDP)
  • 24.95
  • 20.46
  • 1.007E+4
  • 18.04
  • 204.1
  • 0
  • 0
  • 0
  • 0
  • 0
  • 15.74
  • 0
  • 0
  • 7.73
  • 0.9429
  • 34.19
  • 475.7

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 1.852
  • 0.09291
  • 2.185
  • 0.0815
  • 0.08458
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.004644
  • 0
  • 0
  • 0.03493
  • 0.0003689
  • 0.009211
  • -0.1075
Potential incidence of disease due to PM emissions (PM) 2
  • 0.00001427
  • 8.582E-8
  • 6.182E-8
  • 7.55E-8
  • 2.9E-7
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.84E-10
  • 0
  • 0
  • 3.236E-8
  • 1.15E-9
  • 8.347E-9
  • -0.000003055
Potential Soil quality index (SQP) 2
  • 778
  • 14.79
  • 26.53
  • 13.04
  • 16.7
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.1534
  • 0
  • 0
  • 5.59
  • 0.02672
  • 2.729
  • -184.1
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.0001338
  • 1.72E-8
  • 1.883E-8
  • 1.51E-8
  • 0.000002677
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.56E-10
  • 0
  • 0
  • 6.472E-9
  • 2.809E-9
  • 2.032E-9
  • -0.00001677
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 0.000001501
  • 0
  • 8.28E-10
  • 0
  • 3.003E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 6E-12
  • 0
  • 0
  • 0
  • 6.5E-11
  • 1.11E-10
  • -1.957E-7
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 6.144E+4
  • 15.74
  • 28.59
  • 13.82
  • 1278
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2549
  • 0
  • 0
  • 5.924
  • 1.926
  • 2381
  • -1.386E+4