Key Data Set Information | |
Location | DK |
Geographical representativeness description | Denmark |
Reference year | 2023 |
Name |
|
Technical purpose of product or process | Halogen free one-core distribution cable with XLPE insulated copper conductor, copper screen and flame-retardant outer sheath. Conductor: Round, stranded copper conductor Conductor screen: Extruded semi conducting conductor screen PEX Insulation: PEX Insulation screen: Extruded semi conducting insulation screen, strippable Metallic screen: Copper wire screen with copper counterspiral Sheath: Halogen-free compound, UV stabilized |
Classification |
Class name
:
Hierarchy level
|
General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. |
Copyright | Yes |
Owner of data set | |
Quantitative reference | |
Reference flow(s) |
|
Biogenic carbon content |
|
Time representativeness | |
Data set valid until | 2028 |
Time representativeness description | "2023-11-14" - "2028-11-14" |
Technological representativeness | |
Technology description including background system | Standards applied: HD 620 Part 10-D, HD 622 Part 4-A Rated voltage: 17,5 kV Maximum short circuit temperature: 250 °C Minimum temperature during installation: 0 °C Maximum conductor temperature: 90 °C Minimum bending radius: 15 x D Maximum pulling force when connected to all conductors: 50 N/mm2 |
Subtype | specific dataset | ||||
LCA methodology report | |||||
Data sources, treatment and representativeness | |||||
Documentation of data quality management | |||||
Data source(s) used for this data set | |||||
Completeness | |||||
Validation | |||||
| |||||
Compliance Declarations |
Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
Data generator | |
Data set generator / modeller |
|
Data entry by | |
Time stamp (last saved) | 2023-11-14T19:16:24 |
Data set format(s) | |
Publication and ownership | |
UUID | 4321cb79-c112-4938-9a41-30ded4430e34 |
Date of last revision | 2023-10-20T16:59:41.7948322Z |
Data set version | 00.03.000 |
Registration authority | |
Registration number | NEPD-5252-4584-EN |
Owner of data set | |
Copyright | Yes |
License type | Free of charge for all users and uses |
Access and use restrictions | None |
Indicators of life cycle