Close Go back Collapse all sections
Process Data set: Indoor Voltage Sensor KEVA 24 C2 4.1c (en) en

Key Data Set Information
Location CH
Geographical representativeness description Europe
Reference year 2024
Name
Indoor Voltage Sensor KEVA 24 C2 4.1c
Use advice for data set The life cycle assessment of the KEVA 24 C2 4.1c, an EEPS (Electronic and Electrical Products and Systems), is a “cradle-to-grave” analysis. The figure below shows the product life cycle stages and the information considered in the LCA.
Technical purpose of product or process The product declared in this Environmental Product Declaration is the indoor voltage sensor KEVA 24 C2 4.1c, including related accessories and packaging. Voltage sensors offer an alternative way of making the voltage measurement needed for the protection and monitoring of medium voltage power systems. Sensors based on alternative principles have been introduced as successors to conventional instrument transformers in order to significantly reduce size, increase safety, and to provide greater rating standardization and a wider functionality range. The voltage sensor type KEVA C is intended for use in voltage measurement in gas insulated medium voltage switchgear. The voltage sensor KEVA C has been designed as easy replacement of originally used insulating plugs in the cable connectors. Due to their compact size and optimized design sensors can be used for retrofit purposes as well as in new installations. This declaration can be used to represent the following voltage sensors by using the scaling factors given in the table on page 15: KEVA 24 C10c, KEVA 24 C11c, KEVA 24 C21c, KEVA 24 C22c, KEVA 24 C23c, KEVA 24 C24c, KEVA 24 C25c, KEVA 24 C26c, KEVA 24 C30. General technical specifications of the product are presented below. Technical information Unit Value Outer height/diameter mm 159/75 Insulation level kV 24/50/125 Rated primary V up to 22/v3 Accuracy class - 0.5 / 3P Frequency Hz 50 / 60 The production of the instrument sensors, from which medium indoor voltage sensor KEVA 24 C2 4.1c is part of, is located in the ABB Brno Videnska factory. The instrument sensors are produced and assembled directly in the ABB factory combined with components produced by ABB’s suppliers. ABB Brno ELDS adopts and implements for its own activities an integrated Quality/Environmental/Health Management System in compliance with the following standards: • UNI EN ISO 9001:2015 - Quality Management Systems- Requirements • UNI EN ISO 14001:2015 - Environmental Management Systems • UNI EN ISO 45001:2018 - Occupational Health and Safety Management system The constituent materials of KEVA 24 C2 4.1c are presented below. Type Material Weight [kg] Weight [%] Metals Aluminium 0.035 3.18 Brass 0.048 4.38 Copper 0.089 8.11 Steel 0.065 5.91 Plastics and rubbers PP 0.094 8.55 PUR 0.010 0.95 Rubber 0.003 0.28 Other polymers 0.004 0.33 Others Epoxy resin 0.734 66.61 Others 0.019 1.68 Total 1.101 100
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Both primary and secondary data are used. The main sources for primary data are the bill of materials and technical drawings, while site specific foreground data are provided by ABB. Furthermore, information and data obtained from other LCA studies are also used. For all processes for which primary data are not available, generic data originating from the ecoinvent v3.9.1 database, “allocation, cut-off by classification”, are used. The LCA software used for the calculations is SimaPro 9.5. The utility consumption and waste generation by ABB, in the core manufacturing stage, is allocated to the production of one reference product according to applicable rules. For the end-of-life allocation, the “Polluter Pays” principle is adopted according to what is defined in the CEN/TR 16970 standard. However, the potential benefits and avoided loads from recovery and recycling processes are not considered because it is not required by the PCR. The materials that were excluded are glue, and adhesive, as their mass represents less than 2% of that of the whole product, as stated in the paragraph of cut-off criteria of EPDItaly015: “Materials making up the sensor itself whose total mass does not exceed 2% of the total weight of the device”. The same applies for tape and labels used in packaging, which are even a smaller fraction of the total mass. Sandblasting of capacitors and phosphating were also excluded due to the model complexity and unavailability of reference data.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description 2024-11-18 - 2029-11-18
Technological representativeness

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Waste processing
C3
Input
  • 33.26
  • 0.0156
  • 0.00149
  • 217
  • 0.107
Input
  • 2.788
  • 0
  • 0
  • 0
  • 0
Input
  • 36.09
  • 0.0156
  • 0.00149
  • 217
  • 0.107
Input
  • 89.05
  • 1
  • 0.0682
  • 1.13E+3
  • 1.12
Input
  • 2.012
  • 0
  • 0
  • 0
  • 0
Input
  • 91.1
  • 1
  • 0.0682
  • 1.13E+3
  • 1.12
Input
  • 0.09347
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.08712
  • 0.000143
  • 0.0000145
  • 0.885
  • 0.000491
Output
  • 0.00209
  • 0.0000064
  • 3.92E-7
  • 0.00143
  • 0.00000395
Output
  • 1.215
  • 0.0491
  • 0.058
  • 3.1
  • 0.938
Output
  • 0.000115
  • 3.27E-7
  • 2.89E-8
  • 0.00824
  • 0.00000208
Output
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.1144
  • 0
  • 0.0561
  • 0
  • 0.189
Output
  • 0.00702
  • 0
  • 0.0432
  • 0
  • 0
Output
  • 0.00976
  • 0
  • 0.102
  • 0
  • 0
Output
  • 0.02
  • 0
  • 0.183
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Waste processing
C3
Abiotic depletion potential - fossil resources (ADPF)
  • 91.1
  • 1
  • 0.0682
  • 1.13E+3
  • 1.12
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.001635
  • 2.28E-7
  • 1.62E-8
  • 0.0000978
  • 6.63E-7
Acidification potential, Accumulated Exceedance (AP)
  • 0.1262
  • 0.000292
  • 0.0000262
  • 0.247
  • 0.000449
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.2447
  • 0.0000641
  • 0.0665
  • 1.81
  • 0.0101
Global Warming Potential - fossil fuels (GWP-fossil)
  • 5.673
  • 0.0704
  • 0.00887
  • 49.2
  • 0.0859
Global Warming Potential - total (GWP-total)
  • 5.442
  • 0.0705
  • 0.0754
  • 51.1
  • 0.0962
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.01054
  • 0.0000344
  • 0.00000259
  • 0.123
  • 0.000129
No records found.
No records found.
No records found.
No records found.
No records found.
Eutrophication potential - freshwater (EP-freshwater)
  • 0.01007
  • 0.00000496
  • 7.44E-7
  • 0.0449
  • 0.00003
Eutrophication potential - marine (EP-marine)
  • 0.01056
  • 0.000111
  • 0.000032
  • 0.0439
  • 0.00013
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.1276
  • 0.00119
  • 0.000112
  • 0.387
  • 0.00118
Photochemical Ozone Creation Potential (POCP)
  • 0.03884
  • 0.000427
  • 0.0000372
  • 0.125
  • 0.000367
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.000001399
  • 1.54E-9
  • 9.8E-11
  • 8.83E-7
  • 9.94E-10
Water (user) deprivation potential (WDP)
  • 3.125
  • 0.00408
  • 0.000368
  • 1.16
  • 0.0129

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Waste processing
C3
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0
  • 0
  • 0
  • 0
  • 0
Potential incidence of disease due to PM emissions (PM) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Soil quality index (SQP) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 0
  • 0
  • 0
  • 0
  • 0