| Key Data Set Information | |
| Location | NO |
| Geographical representativeness description | Europe |
| Reference year | 2025 |
| Name |
|
| Use advice for data set | The analysis is a cradle-to-grave study made for one luminaire manufactured , installed and used in a tunnel over the lifetime. Modules A1-A5 are included in the analysis. It includes the extraction and production of raw materials, transportation to the factory, the production process itself, transportation to market and installation of the product. B6 is the operational energy usage based on a normal use. C1-C4, D are mandatory modules which include end of life treatment of materials and the benefits from recycling. |
| Technical purpose of product or process | These operating instructions apply to the products listed in Technical Data HFXE LED BG2. Barel reserves the right to change technical specifications without further notice. Unauthorized copying or modification of this content is not permitted. This Ex component is suitable for incorporation into Ex-enclosure – typically Ex e luminaire. Locally connected battery will be charged and monitored during normal mains supply conditions. Loss of mains supply will initiate a 90 or 180 minutes (preset) operation of the normally powered LED-lamp. The LED lamp will return to normal operation when stabile mains supply returns. |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) can be excluded. These cut-off criteria do not apply for hazardous materials and substances. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2030 |
| Time representativeness description | 2025-09-12 - 2030-09-12 |
| Technological representativeness | |
| Technology description including background system | Approvals : QAN/QAR: 0470 Nemko 01ATEX452Q/ NO/NEM/QAR08.0001/04 Ex protection Code: Ex II 2G Ex eb mb IIC Gb IECEx Certificate: IECEx EXV 22.0018U ATEX no: ExVeritas 22 ATEX 1237U According to directives and standards listed: ATEX Directive 2014/34/EU EN 60079-0 Explosive atmospheres -- Part 0: Equipment - General requirements EN 60079-7 Explosive atmospheres - Part 7: Equipment protection by increased safety "e" EN 60079-18 Explosive atmospheres - Part 18: Equipment protection by encapsulation "m" IECEx Scheme IEC 60079-0 Explosive atmospheres - Part 0: Equipment - General requirements IEC 60079-7 Explosive atmospheres - Part 7: Equipment protection by increased safety "e" IEC 60079-18 Explosive atmospheres - Part 18: Equipment protection by encapsulation "m" EMC-Directive 2014/30/EU EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment EN 61000-3-2 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 A per phase) EN 61000-3-3 Electromagnetic compatibility (EMC) -- Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection EN 61547 Equipment for general lighting purposes - EMC immunity requirements EN/IEC60533:2015 Electrical and electronic installations in ships - Electromagnetic compatibility (EMC) - Ships with a metallic hull Low Voltage Directive 2014/35/EU EN 61347-1 Lamp controlgear -- Part 1: General and safety requirements EN 61347-2-13 Lamp controlgear - Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED module RoHS Directive 2011/65/EU EN 50581 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2025-10-24T15:47:24 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 3c498b61-a5b2-4d78-b5e3-635a797a10f5 |
| Date of last revision | 2025-09-11T14:13:46.3320975Z |
| Data set version | 00.02.001 |
| Registration authority | |
| Registration number | NEPD-12326-12382 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle