| Key Data Set Information | |
| Location | NO |
| Geographical representativeness description | Norway |
| Reference year | 2025 |
| Name |
|
| Technical purpose of product or process | BFOU M 1kV Armored, fire-resistant, flame-retardant, halogen-free power cable. Fixed installation for power, control and lighting in both EX (Zone 0, 1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the Oil & Mud resistance requirement in NEK TS 606:2016. Conductor material Copper Conductor surface Tinned Core insulation material Mica + polymer Core identification (acc. HD 308 S2) Yes Armoring/reinforcement Braiding Armoring Yes Armoring/reinforcement material Copper, tinned Material inner sheath Halogen free polymer Material outer sheath EVA rubber Cable shape Round Max. conductor temperature [°C] 90 Max. conductor temperature at short circuit [°C] 250 |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2030 |
| Time representativeness description | 2025-06-02 - 2030-06-02 |
| Technological representativeness | |
| Technology description including background system | BFOU M 1kV 2x4/6mm2 P5/P12/P105 BK SAP code: 20110526 El. no: 1043622 STANDARDS APPLIED: NEK TS 606:2022 Cables for offshore installations IEC 60092-353 Design standard IEC 60228 Class 2 or class 5 Conductors IEC 60092-360 Insulation and sheath IEC 60092-350 General construction and test methods for power, control and instrumentation cables for shipboard and offshore applications IEC 61892-4 Table 4 Current rating at 45°C ambient temperature IEC 61892-4 Table 4 IEC 60331-1/2 and IEC 60331-21 Fire resistant properties: IEC 60331-1 & -2 (120 minutes @ 830°C), IEC 60331-21 (180 minutes @ 1000°C) IEC 60332-1-2 and IEC 60332-3-22(Cat.A) Flame retardant properties IEC 60754-1 and IEC 60754-2 Halogen free properties: IEC 60754-1 (pH = 4,3, Conductivity = 10µS), IEC 60754-2 ( < 0,5% Halogen) IEC 61034-1, -2 Low smoke properties: IEC 61034-1, -2 (minimum 60% light transmittance) Oil resistant IEC 60092-360 IRM 902 oil (168 hours @ 100°C) MUD resistant (IEC 60092-360 & NEK TS 606) IRM 903 oil (168 hours @ 100°C), Calcium Bromide Brine (56 days @ 70°C), EDC 95-11 base oil (56 days @ 70°C) ISO 4892 part 3 UV and Ozone resistance |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2025-08-08T13:09:31 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 39d389d2-edac-4fec-9bc9-6dfa54b54506 |
| Date of last revision | 2025-05-28T14:09:38.1945368Z |
| Data set version | 00.03.000 |
| Registration authority | |
| Registration number | NEPD-11264-11193 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |