Close Go back Collapse all sections
Process Data set: Injection moulded PP sockets, reducers, chamber elements and stormbox elements (en) en

Key Data Set Information
Location PL
Geographical representativeness description Mainly Norway, but also Europe.
Reference year 2025
Name
Injection moulded PP sockets, reducers, chamber elements and stormbox elements
Use advice for data set The analysis is a cradle-to-gate (A1 - A3) study, with option A4 transport to market. It includes the extraction and production of raw materials, transportation to the production site, the production process itself and transport to the market. A5, installation, is included for the transport of packaging waste from the construction site and the treatment of this waste - not the installation of the products. The data in A1 is generated from the cradle to gate part (A1-A3) of an internally verified EPD from Pipelife Polen's Kartoszyno production site. A2 covers the specific transportation of the product from Kartoszyno to Pipelife Norway, Surnadal.
Technical purpose of product or process Injection moulded PP sockets, reducers and chambers used in pipelines for sewerage and surface water. Injection moulded PP stormboxes for retention and infiltration of rainwater. More information is found on https://www.pipelife.no/ Products declared in this EPD are manufactured by Pipelife Poland SA, and transported to Pipelife Norway AS, Surnadal, for storage before further transportation to customer. A1: includes A1-A3 of an internally verified EPD for the Polish production. A2: incluces transportation from Pipelife Poland to Pipelife Norway, Surnadal. A3: includes no data. Reloading/handling is considered as negligible. A4: includes transportation from Surnadal to generic customer The products covered by this EPD have small variations in composition and are manufactured with the same type of equipment. The composition below represents an average for these products manufactured in 2023.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Piping
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is not allocated among purchased products which are not further processed, only reloaded and handled, before leaving Surnadal. Cut-off criteria: All raw materials and all the essential energy are included.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 1.0 kg
  • Carbon content (biogenic) - packaging: 1.0 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-08-19 - 2030-08-19
Technological representativeness
Technology description including background system Mainly, the products covered by this EPD are PP sockets and reducers for DN/OD and DN/ID structured wall pipe systems according to EN 13476-3, PP fittings for smooth wall pipe systems according to EN 1852, PP chambers according to EN 13598-2 and stormbox elements according to EN 17152. For bends and branches manufactured by Pipelife Poland SA, see separate EPD. See our handbook regarding the properties of PP: https://www.pipelife.no/content/dam/pipelife/norway/marketing/general/r%C3%B8rh%C3%A5ndboka/r%C3%B8rh%C3%A5ndboka2021/M-Materialdata.pdf

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 1.297
  • 0.003535
  • 0.004588
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.02561
  • 0
  • -9.841
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 1.323
  • 0.003535
  • -9.837
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 46.28
  • 0.247
  • 0.2325
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 32.69
  • 0
  • -0.1784
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 78.97
  • 0.247
  • 0.05408
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.000772
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.05843
  • 0.0001265
  • 0.0001369
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.01324
  • 0.0004522
  • 0.001362
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.02165
  • 0.00002641
  • 0.0001567
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.002939
  • 0.00001274
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.2926
  • 0.01201
  • 0.7948
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.00006162
  • 0.000001682
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.02459
  • 0
  • 0.198
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.0005408
  • 0
  • 0.5947
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 6.624E-7
  • 0
  • 0.4154
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.00001002
  • 0
  • 6.284
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 76.17
  • 0.247
  • 0.2324
  • 0
  • 0
  • 0
  • 0
  • 0
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.00002655
  • 4.512E-7
  • 3.378E-7
  • 0
  • 0
  • 0
  • 0
  • 0
Acidification potential, Accumulated Exceedance (AP)
  • 0.008975
  • 0.00004694
  • 0.000142
  • 0
  • 0
  • 0
  • 0
  • 0
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.01698
  • 0.000006761
  • 1.244
  • 0
  • 0
  • 0
  • 0
  • 0
Global Warming Potential - fossil fuels (GWP-fossil)
  • 2.285
  • 0.01633
  • 0.01935
  • 0
  • 0
  • 0
  • 0
  • 0
Global Warming Potential - total (GWP-total)
  • 2.302
  • 0.01635
  • 1.263
  • 0
  • 0
  • 0
  • 0
  • 0
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0006157
  • 0.000005814
  • 0.000005155
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.179
  • 0.01635
  • 0.9009
  • 0
  • 0
  • 0
  • 0
  • 0
Eutrophication potential - freshwater (EP-freshwater)
  • 0.00003099
  • 1.305E-7
  • 2.157E-7
  • 0
  • 0
  • 0
  • 0
  • 0
Eutrophication potential - marine (EP-marine)
  • 0.001678
  • 0.000009289
  • 0.00005956
  • 0
  • 0
  • 0
  • 0
  • 0
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.01838
  • 0.0001039
  • 0.000636
  • 0
  • 0
  • 0
  • 0
  • 0
Photochemical Ozone Creation Potential (POCP)
  • 0.007776
  • 0.0000398
  • 0.0001653
  • 0
  • 0
  • 0
  • 0
  • 0
Depletion potential of the stratospheric ozone layer (ODP)
  • 1.008E-7
  • 3.7E-9
  • 3.233E-9
  • 0
  • 0
  • 0
  • 0
  • 0
Water (user) deprivation potential (WDP)
  • 62.79
  • 0.2389
  • 0.3476
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.05548
  • 0.001079
  • 0.000875
  • 0
  • 0
  • 0
  • 0
  • 0
Potential incidence of disease due to PM emissions (PM) 2
  • 8.056E-8
  • 1E-9
  • 1.78E-9
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Soil quality index (SQP) 2
  • 5.055
  • 0.1728
  • 0.1372
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 1.506E-8
  • 2E-10
  • 1.197E-9
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 4.2E-10
  • 0
  • 2.6E-11
  • 0
  • 0
  • 0
  • 0
  • 0
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 12.84
  • 0.1831
  • 0.2737
  • 0
  • 0
  • 0
  • 0
  • 0