| Key Data Set Information | |
| Location | DE |
| Geographical representativeness description | Europe |
| Reference year | 2024 |
| Name |
|
| Technical purpose of product or process | Module used to control fire dampers, air transfer dampers, duct smoke detectors and multileaf dampers. The module is used to connect the control system with the components. For more infomation see: https://www.trox.de/en/troxnetcom-as-i---modules/as-em-9c3d5cb7972540a5 Module used to control fire dampers, air transfer dampers, smoke detectors and multileaf dampers: fire damper / multileaf damper: actuator with spring return (2DI/1DO); smoke control damper / multileaf damper: actuator without spring return (2DI/2DO); air transfer damper: actuator with spring return and smoke detector RM-O-3-D (4DI/2DO); 24 V terminal. F. RM); smoke detector (4DI/ 2DO) Capturing the damper blade end positions(CLOSED and OPEN) as well as intermediate positions. Actuators can be started even without controller communication. Emergency position can be set (OPEN or CLOSED). LEDs for OPEN and CLOSED positions; monitoring of running time errors. Integral AS-Interface slave. Monitoring of signal receipt. Master can be used to monitor the running time of the damper blade actuator. Connection with flat cable insulation displacement connector. Supply voltage of the module and 24 V DC actuator using AS-Interface (2-wire control). Plug-in connection for Belimo actuators. This EPD includes the environmental data of the product series AS-EM. The following represents a representative dataset of the most sold variant in the declared sales year (AS-EM). |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Energy, water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2029 |
| Time representativeness description | "2024-05-09" - "2029-05-09" |
| Technological representativeness | |
| Technology description including background system | Electrical design: 4 inputs/3 outputs Output function: PNP transistor Supply voltage: 26.5 – 31.6 V DC Current consumption, incl. actuator: 450 mA Switching: DC PNP Sensor voltage supply: AS-i Voltage range: 18 – 30 V DC With short circuit protection: Yes Switching level – high signal: 1 10 Input current high/low: > 7 mA/< 2 mA Input characteristic: IEC 61131-2 Type 2 Galvanically isolated: No With short circuit protection: Yes Max. current load per output: 400 mA per output/400 in total (from AS-i) Galvanically isolated: Yes Maximum voltage: 32 V Max. current load: 500 mA Ambient temperature: –5 to 75 °C IP protection level: IP 42 AS-i profile: S-7.A.E I/O configuration: 7 Hex ID code: 7 Hex EMC: EN 61000-6-2; EN 61000-6-3 For more technical data see: https://www.trox.de/en/troxnetcom-as-i---modules/as-em-9c3d5cb7972540a5 |
| Subtype | representative dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2024-05-11T16:19:46 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 2772a90d-d974-4587-8bb1-1ef627767764 |
| Date of last revision | 2023-12-19T10:52:23.8427212Z |
| Data set version | 00.03.000 |
| Registration authority | |
| Registration number | NEPD-5685-4946-EN |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle