| Key Data Set Information | |
| Location | GB |
| Geographical representativeness description | UK |
| Reference year | 2025 |
| Name |
|
| Technical purpose of product or process | Exposed Ceiling Swirl Diffuser Ceiling swirl diffusers in air conditioning systems create a swirl to supply air to rooms. The resulting airflow induces high levels of room air, thereby rapidly reducing the airflow velocity and the temperature difference between supply air and room air. Ceiling swirl diffusers allow for large volume flow rates. The result is a mixed flow ventilation in comfort zones, with good overall room ventilation, creating only very little turbulence in the occupied zone. Type TELLUS-LOV ceiling diffusers have fixed perforations and an adjustable slot between the diffuser face and plenum. Horizontal air discharge from the slot is radial providing an attachment surface for facia swirl. The supply air to room air temperature difference may range from -10 to +4K. Ceiling swirl diffuser for exposed mounting installations. Diffuser face made of sheet steel with polyester powder-coat finish from RAL Classic color range. Plenum box made of galvanised steel, natural finish with optional polyester powder-coat finish from RAL Classic color range. This EPD includes the environmental data of the product series TELLUS-LOV (GB). The following represents a representative dataset of the most sold variant in the declared sales year (TELLUS-V2-0-0-H-D12/200x248/P3/0) with factors for alternative sizes. |
| Classification |
Class name
:
Hierarchy level
|
| General comment on data set | Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Energy, water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. |
| Copyright | Yes |
| Owner of data set | |
| Quantitative reference | |
| Reference flow(s) |
|
| Biogenic carbon content |
|
| Time representativeness | |
| Data set valid until | 2030 |
| Time representativeness description | 2025-11-08 - 2030-11-08 |
| Technological representativeness | |
| Technology description including background system | Nominal diffuser sizes: 100, 125, 160, 200, 250, 315 mm. Minimum volume flow rate, with dTz = -6K: 20 – 136 l/s or 72 – 490 m³/h. Maximum volume flow rate, with LWA 50 dB(A): 52 – 337 l/s or 187 – 1213 m³/h. Supply air to room air temperature difference: -10K to +4 K. For more technical data see: https://www.troxuk.co.uk/ceiling-swirl-diffusers/tellus-15c5ff77f6f012d5 |
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
EN 15804+A2
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Compliance |
Compliance system name
|
Approval of overall compliance
Fully compliant |
Nomenclature compliance
Fully compliant |
Methodological compliance
Fully compliant |
Review compliance
Fully compliant |
Documentation compliance
Fully compliant |
Quality compliance
Fully compliant |
| Data generator | |
| Data set generator / modeller |
|
| Data entry by | |
| Time stamp (last saved) | 2025-11-08T13:40:07 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 12aa45b1-10bc-4e74-a40b-425aaddbf5a0 |
| Date of last revision | 2025-09-24T07:39:26.3063352Z |
| Data set version | 00.02.001 |
| Registration authority | |
| Registration number | NEPD-12439-12529 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |
Indicators of life cycle