Close Go back Collapse all sections
Process Data set: IFXI LX NH 90 3G2,5 Antitwin (en) en

Key Data Set Information
Location NO
Geographical representativeness description Nordic
Reference year 2025
Name
IFXI LX NH 90 3G2,5 Antitwin
Use advice for data set Cradle to Gate. The following stages have been declared: A1-A4
Technical purpose of product or process IFX LX 90 building wire to be used for indoor installations, non protected, installed in trunk or pipe on wall, sealing or in deck. Outdoor installed - mechanical protection is required. Current rating shall be based on maximum 70° ambient temperature. Packaging solution result in a "Non spinning" outlook. General: Factory Standard
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Data from material supplier and the LCA generator has been accepted "As-Is" Data from processing TECCON in-house has been repeated ongoingly without major deviations. Figures given in document are worst case values. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. The allocation is made in accordance with the guidelines given in EN 15804. Raw material - Information derived from manufactory and from a LCA generator Processing: Derived from actual measurements during production of the individual units/stages Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances. All major materials have been included. Substance representing <1% have not been included. This include folio film for packaging!
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.007110091738 kg
Time representativeness
Data set valid until 2030
Time representativeness description 2025-04-10 - 2030-04-10
Technological representativeness
Technology description including background system Construction standards Factory Standard Conductor Rigid bare copper EN60228 class 1 Insulation - conductor XLPE Conductor marking Colored acc. Cenelec Conductor laying Twisted Bedding PVC Jacket PVC - lead free White Marking PFXP LX 500V + Meter marking Voltage - nominal Uo/U 300/500V Voltage - test 2000V Max Conductor temperature operation 90° Max temperature at Short circuit 5s max 250° Resistance insulation 1000M?*Km Resistant to fire performance EN 50265-2-1; EN 60332-1-2 CPR EN 50575 compliance Eca DoP DOP-0015/20 Temperature - operation -30 to + 70oC Temperature - installation -5 to + 700C Bending radius 5 x D

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 1.039
  • 0.0236
  • 0.1457
  • 0.006148
  • 0.03264
  • 0
  • 0
  • 0.0008402
  • 0.002196
  • -12.41
Input
  • 0.4238
  • 0
  • 0
  • 0
  • -0.4153
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 1.462
  • 0.0236
  • 0.1457
  • 0.006148
  • -0.3827
  • 0
  • 0
  • 0.00084
  • 0.002196
  • -12.41
Input
  • 9.485
  • 1.649
  • 1.019
  • 0.4295
  • 0.636
  • 0
  • 0
  • 0.02858
  • 0.02551
  • -3.277
Input
  • 4.183
  • 0
  • 0
  • 0
  • 0.004101
  • 0
  • 0
  • -4.101
  • 0
  • 0
Input
  • 13.67
  • 1.649
  • 1.019
  • 0.4295
  • 0.6401
  • 0
  • 0
  • -4.072
  • 0.02551
  • -3.277
Input
  • 0.0146
  • 0
  • 0
  • 0
  • 0.0003168
  • 0
  • 0
  • 0
  • 0.00003086
  • 0.04631
Input
  • 0.01846
  • 0.0008442
  • 0.002311
  • 0.0002199
  • 0.0006796
  • 0
  • 0
  • 0.00002368
  • 0.00004655
  • 0.001931
Input
  • 0.01258
  • 0.003019
  • 0.001459
  • 0.0007864
  • 0.001359
  • 0
  • 0
  • 0
  • 0.0008803
  • -0.6556
Input
  • 0.0125
  • 0.0001763
  • 0.0004046
  • 0.00004593
  • 0.0005645
  • 0
  • 0
  • 0.00008072
  • 0.00003109
  • -0.02221
Output
  • 0.00624
  • 0.00008502
  • 0.0005333
  • 0.00002215
  • 0.003239
  • 0
  • 0
  • 0
  • 0.008359
  • -0.00191
Output
  • 0.164
  • 0.08017
  • 0.06517
  • 0.02089
  • 0.05906
  • 0
  • 0
  • 0
  • 0.08364
  • -0.123
Output
  • 0.0000203
  • 0.00001123
  • 0.000007172
  • 0.000002925
  • 0.000003265
  • 0
  • 0
  • 0
  • 1.699E-7
  • -0.00001153
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.1408
  • 0
  • 1.343
  • 0
  • 0
  • 0.0927
  • 0.000004388
  • -0.001812
Output
  • 0
  • 0
  • 0.01756
  • 0
  • 0.003989
  • 0
  • 0
  • 0.1448
  • 8.865E-7
  • -0.0002386
Output
  • 0
  • 0
  • 0.02699
  • 0
  • 0.1756
  • 0
  • 0
  • 0.2809
  • 0.0000138
  • -0.0005847
Output
  • 0
  • 0
  • 0.4083
  • 0
  • 2.657
  • 0
  • 0
  • 4.249
  • 0.0002088
  • -0.008845

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 13.31
  • 1.648
  • 1.011
  • 0.4294
  • 0.7145
  • 0
  • 0
  • 0.02858
  • 0.02551
  • -3.277
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.0001498
  • 0.000003012
  • 2.523E-7
  • 7.846E-7
  • 0.000003814
  • 0
  • 0
  • 1.529E-8
  • 9.578E-9
  • -0.0001504
Acidification potential, Accumulated Exceedance (AP)
  • 0.05323
  • 0.0003133
  • 0.0006614
  • 0.00008163
  • 0.001273
  • 0
  • 0
  • 0.00005471
  • 0.000008817
  • -0.02765
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.01213
  • 0.00004513
  • 0.0001013
  • 0.00001176
  • 0.06007
  • 0
  • 0
  • 0.000003533
  • 7.405E-7
  • -0.001099
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.7341
  • 0.109
  • 0.1133
  • 0.0284
  • 0.05661
  • 0
  • 0
  • 0.4369
  • 0.00643
  • -0.2887
Global Warming Potential - total (GWP-total)
  • 0.7226
  • 0.1091
  • 0.1134
  • 0.02843
  • 0.1167
  • 0
  • 0
  • 0.4369
  • 0.006431
  • -0.2944
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.0005901
  • 0.0000388
  • 0.0000599
  • 0.00001011
  • 0.00002339
  • 0
  • 0
  • 5.188E-7
  • 3.515E-7
  • -0.00455
  • 0.7375
  • 0.1091
  • 0.1212
  • 0.02842
  • 0.0286
  • 0
  • 0
  • 0.4369
  • 0.006538
  • -0.2084
Eutrophication potential - freshwater (EP-freshwater)
  • 0.0005199
  • 8.71E-7
  • 7.96E-7
  • 2.269E-7
  • 0.00001104
  • 0
  • 0
  • 3.35E-8
  • 1.942E-8
  • -0.0001906
Eutrophication potential - marine (EP-marine)
  • 0.001877
  • 0.000062
  • 0.00009736
  • 0.00001615
  • 0.0001227
  • 0
  • 0
  • 0.00002626
  • 0.000008815
  • -0.001436
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.02648
  • 0.0006935
  • 0.00108
  • 0.0001807
  • 0.001147
  • 0
  • 0
  • 0.0002841
  • 0.00003456
  • -0.02066
Photochemical Ozone Creation Potential (POCP)
  • 0.008755
  • 0.0002656
  • 0.0003291
  • 0.00006921
  • 0.0003595
  • 0
  • 0
  • 0.00006801
  • 0.00001094
  • -0.005627
Depletion potential of the stratospheric ozone layer (ODP)
  • 3.574E-8
  • 2.47E-8
  • 1.37E-8
  • 6.434E-9
  • 7.334E-9
  • 0
  • 0
  • 3.35E-10
  • 3.25E-10
  • -0.009236
Water (user) deprivation potential (WDP)
  • 15.2
  • 1.594
  • 9.136
  • 0.4154
  • 1.272
  • 0
  • 0
  • 0.06473
  • 0.4037
  • -22.66

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.02179
  • 0.007205
  • 0.007028
  • 0.001877
  • 0.002378
  • 0
  • 0
  • 0.00004831
  • 0.0001422
  • -0.01425
Potential incidence of disease due to PM emissions (PM) 2
  • 1.001E-7
  • 6.674E-9
  • 5.373E-9
  • 1.739E-9
  • 4.356E-9
  • 0
  • 0
  • 2.14E-10
  • 1.56E-10
  • -1.166E-7
Potential Soil quality index (SQP) 2
  • 7.761
  • 1.153
  • 0.5724
  • 0.3004
  • 0.4603
  • 0
  • 0
  • 0.003468
  • 0.07121
  • -15.25
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 8.487E-7
  • 1.335E-9
  • 5.68E-10
  • 3.48E-10
  • 1.85E-8
  • 0
  • 0
  • 3.66E-10
  • 3.8E-11
  • -3.054E-7
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 9.577E-9
  • 0
  • 9.4E-11
  • 0
  • 2.21E-10
  • 0
  • 0
  • 1E-11
  • 1E-12
  • -3.641E-9
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 398.7
  • 1.222
  • 0.8928
  • 0.3184
  • 9.389
  • 0
  • 0
  • 0.08533
  • 19.15
  • -254.5