Process Data set: IFSI-EMC Pure 1kV 3x120/70mm² FV (en) en

Key Data Set Information
Location SE
Geographical representativeness description Norway
Reference year 2024
Name
IFSI-EMC Pure 1kV 3x120/70mm² FV
Technical purpose of product or process IFSI-EMC PURE 1KV CU Power cable with up to 1 kV operating voltage. Allowed indoors, outdoors and as a ground cable without extra protection. The Cu screen is 100% tight, has low coupling impedance and meets the EMC directive. The 3-conductor is symmetrically constructed and has a cu screen from 1.5mm². Halogen-free cable is recommended used when it is important to avoid the formation of dense smoke and corrosive gases in the event of an overheating or fire. Cables with AAL screen has a construction with an AL-foil in contact with a massive CU wire. The AL foil has an longitudinal slit and is not 100% covering (slit does not exceed 4mm). When applied to installation with highly sensitive equipment use IFSI-EMC Pure with CU screen. Conductor material Copper Conductor surface Bare Core insulation material XLPE Armoring/reinforcement material Copper, bare Screen construction Metallised foil Screen Yes Screen material Copper, bare Concentric conductor Copper Material inner sheath Halogen free polymer Material outer sheath Halogen free polymer Cable shape Round
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Electronic and electrical components and products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description "2024-10-17" - "2029-10-17"
Technological representativeness
Technology description including background system IFSI-EMC Pure 1kV 3x120/70mm² FV SAP code 20193399 El no. 1003821 STANDARDS APPLIED: HD 604-5D Construction IEC 60502-1 Construction IEC 60228 Class 1 or Class 2 Conductors EN 50575:2014 + A1:2016 CPR standard - Fire properties EN 60754-1 and EN 60754-2 Halogen free properties: EN 60754-1 (pH = 4,3, Conductivity = 10µS), EN 60754-2 ( < 0,5% Halogen) IEC 61034-1, -2 Low smoke properties: IEC 61034-1, -2 (minimum 60% light transmittance)

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 50.55
  • 0.02713
  • 10.1
  • 0.0586
  • 1.217
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.6705
  • 0
  • 0
  • 0.04522
  • 0.0041
  • 0.07141
  • -6.257
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 50.55
  • 0.02713
  • 10.1
  • 0.0586
  • 1.217
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.6705
  • 0
  • 0
  • 0.04522
  • 0.0041
  • 0.07141
  • -6.257
Input
  • 210.8
  • 2.134
  • 21.35
  • 4.656
  • 4.856
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.05185
  • 0
  • 0
  • 3.204
  • 0.0821
  • 0.555
  • -7.034
Input
  • 13.38
  • 0
  • 0
  • 0
  • 0.004029
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -13.18
  • 0
  • 0
Input
  • 224.2
  • 2.134
  • 21.35
  • 4.656
  • 4.86
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.05185
  • 0
  • 0
  • 3.204
  • -13.1
  • 0.555
  • -7.034
Input
  • 0.5716
  • 0
  • 0
  • 0
  • 0.01143
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.211
Input
  • 1.276
  • 0.000951
  • 0.03965
  • 0.00205
  • 0.02644
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0005266
  • 0
  • 0
  • 0.001618
  • 0.00009148
  • 0.001481
  • 0.01942
Input
  • 0.01223
  • 0.003206
  • 0.1277
  • 0.00687
  • 0.003124
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.001312
  • 0
  • 0
  • 0.005778
  • 0
  • 0.0004411
  • -0.1745
Input
  • 0.3716
  • 0.0002406
  • 0.02471
  • 0.0005301
  • 0.007975
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.005008
  • 0
  • 0
  • 0.0003374
  • 0.0005919
  • 0.0007231
  • -0.02206
Output
  • 0.1335
  • 0.0001159
  • 0.102
  • 0.0002548
  • 0.005924
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00003324
  • 0
  • 0
  • 0.0001634
  • 0
  • 0.06013
  • -0.008196
Output
  • 7.175
  • 0.1765
  • 0.1554
  • 0.405
  • 0.1969
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.003988
  • 0
  • 0
  • 0.1531
  • 0
  • 1.781
  • -0.3616
Output
  • 0.0009245
  • 0.00001457
  • 0.0003175
  • 0.00003178
  • 0.00002628
  • 0
  • 0
  • 0
  • 0
  • 0
  • 4.636E-7
  • 0
  • 0
  • 0.00002185
  • 0
  • 0.000003855
  • -0.00001035
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.006714
  • 0
  • 0.04414
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.2
  • 0.0000251
  • -0.008257
Output
  • 0
  • 0
  • 0.3822
  • 0
  • 0.01347
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.291
  • 6.138E-7
  • -0.001087
Output
  • 0
  • 0
  • 0.2226
  • 0
  • 0.01394
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.4743
  • 0.00003982
  • -0.002664
Output
  • 0
  • 0
  • 3.367
  • 0
  • 0.2109
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 7.175
  • 0.0006025
  • -0.0403

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 223.4
  • 2.134
  • 21.3
  • 4.655
  • 5.107
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.05177
  • 0
  • 0
  • 3.204
  • 0.08179
  • 0.555
  • -7.036
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.00745
  • 0.000002488
  • 0.000007541
  • 0.000005111
  • 0.0001494
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.828E-7
  • 0
  • 0
  • 0.000005756
  • 6.058E-8
  • 1.837E-7
  • -0.0006786
Acidification potential, Accumulated Exceedance (AP)
  • 0.7726
  • 0.0005984
  • 0.00136
  • 0.001258
  • 0.01554
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00002963
  • 0
  • 0
  • 0.0008686
  • 0.0001358
  • 0.0001874
  • -0.1214
Global Warming Potential - biogenic (GWP-biogenic)
  • 0.3259
  • 0.0000564
  • 0.04675
  • 0.0001228
  • 0.007984
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0001049
  • 0
  • 0
  • 0.00008664
  • 0.01776
  • 0.008516
  • -0.003438
Global Warming Potential - fossil fuels (GWP-fossil)
  • 16.02
  • 0.1378
  • 0.4053
  • 0.2993
  • 0.3569
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.003793
  • 0
  • 0
  • 0.2125
  • 0.7195
  • 0.05379
  • -0.7626
Global Warming Potential - total (GWP-total)
  • 16.36
  • 0.1379
  • 0.4637
  • 0.2995
  • 0.3655
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.003913
  • 0
  • 0
  • 0.2127
  • 0.7372
  • 0.06232
  • -0.7682
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.01667
  • 0.00004129
  • 0.01165
  • 0.00008738
  • 0.0005707
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.00001565
  • 0
  • 0
  • 0.00007428
  • 0.000002222
  • 0.0000089
  • -0.002194
  • 16.32
  • 0.1379
  • 0.4538
  • 0.2995
  • 0.3645
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.003905
  • 0
  • 0
  • 0.2127
  • 0.7332
  • 0.06713
  • -0.3846
Eutrophication potential - freshwater (EP-freshwater)
  • 0.006314
  • 0.000001051
  • 0.00001325
  • 0.000002282
  • 0.0001267
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.728E-7
  • 0
  • 0
  • 0.000001669
  • 1.113E-7
  • 4.696E-7
  • -0.0008196
Eutrophication potential - marine (EP-marine)
  • 0.05224
  • 0.0001785
  • 0.0003372
  • 0.0003783
  • 0.001071
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.000003257
  • 0
  • 0
  • 0.0002576
  • 0.00006489
  • 0.000114
  • -0.005085
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.7742
  • 0.001974
  • 0.003339
  • 0.004184
  • 0.01576
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0000424
  • 0
  • 0
  • 0.002849
  • 0.0006742
  • 0.000753
  • -0.07833
Photochemical Ozone Creation Potential (POCP)
  • 0.1895
  • 0.0006277
  • 0.0008054
  • 0.001345
  • 0.003871
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0000114
  • 0
  • 0
  • 0.0008723
  • 0.0001623
  • 0.0002224
  • -0.02128
Depletion potential of the stratospheric ozone layer (ODP)
  • 0.000001313
  • 3.177E-8
  • 9.311E-8
  • 6.916E-8
  • 3.128E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.6E-10
  • 0
  • 0
  • 4.844E-8
  • 1.221E-9
  • 6.82E-9
  • -0.003031
Water (user) deprivation potential (WDP)
  • 1073
  • 1.672
  • 2127
  • 3.571
  • 64.44
  • 0
  • 0
  • 0
  • 0
  • 0
  • 9.025
  • 0
  • 0
  • 3.057
  • 0.4792
  • 13.23
  • 32.07

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 1.001
  • 0.009327
  • 0.7193
  • 0.02035
  • 0.03536
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0009393
  • 0
  • 0
  • 0.01401
  • 0.0001916
  • 0.003597
  • -0.0118
Potential incidence of disease due to PM emissions (PM) 2
  • 0.000002146
  • 1.186E-8
  • 1.065E-8
  • 2.635E-8
  • 4.428E-8
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.12E-10
  • 0
  • 0
  • 1.53E-8
  • 5.89E-10
  • 3.292E-9
  • -2.628E-7
Potential Soil quality index (SQP) 2
  • 183.3
  • 2.341
  • 9.611
  • 5.34
  • 4.078
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.02607
  • 0
  • 0
  • 2.209
  • 0.01388
  • 1.1
  • -18.11
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 0.00001332
  • 1.529E-9
  • 9.971E-9
  • 3.293E-9
  • 2.667E-7
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.65E-10
  • 0
  • 0
  • 2.55E-9
  • 1.454E-9
  • 7.91E-10
  • -0.00000135
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.767E-7
  • 0
  • 4.13E-10
  • 0
  • 3.544E-9
  • 0
  • 0
  • 0
  • 0
  • 0
  • 1.1E-11
  • 0
  • 0
  • 0
  • 3.3E-11
  • 4.3E-11
  • -1.577E-8
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 9682
  • 1.561
  • 12.61
  • 3.405
  • 212.2
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.2359
  • 0
  • 0
  • 2.36
  • 1.037
  • 908.1
  • -1117